3 <br />Cn <br />CD <br />cc <br />01 <br />Z <br />0 <br />N <br />O <br />O <br />Ln <br />0 <br />(V <br />0 <br />W <br />0 <br />GENERAL NOTES <br />GENERAL NOTES <br />COMBINATION OF ROOF AND SOFFIT VENTS PER R806.2 <br />DRYWALL <br />— DO NOT SCALE DRAWINGS <br />o 40%-50% OF REQUIRED VENTILATION SHALL BE PROVIDED IN THE UPPER PORTION OF THE ATTIC <br />— ��" SAG —RESISTANT GYPSUM CEILING BOARD SHALL BE USED ON CEILINGS WITH 24" O.C. SPANS <br />— ALL WORK MUST. BE COMPLETED TO THE APPLICABLE FLORIDA BUILDING CODES <br />LOCATED NO MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE. THE REMAINING <br />ACCESSIBILITY <br />— ANY ERRORS OR OMISSIONS SHALL BE REPORTED TO A PULTE REPRESENTATIVE <br />VENTILATION SHALL BE OBTAINED THROUGH SOFFIT VENTS <br />— ONE BATHROOM LOCATED ON HABITABLE GRADE LEVELS SHALL PROVIDE A DOOR THAT HAS A 29" CLEAR <br />— CONTRACTORS SHALL MAINTAIN A CLEAN JOB SITE <br />— PROVIDE MIN. 1' FREE SPACE BETWEEN INSULATION AND ROOF SHEATHING <br />OPENING PER R320.1.1. A POWDER BATH CAN BE USED IF THERE ARE NO BATHS ON THE GROUND FLOOR <br />Ask <br />— CONTRACTORS ARE RESPONSIBLE TO FOLLOW ALL APPLICABLE OSHA REGULATIONS <br />— ATTIC ACCESS IS REQUIRED WHEN THE HEIGHT IS GREATER THAN 30" AND THE AREA IS GREATER <br />WITH A TUB OR SHOWER <br />TERMITE PROTECTION <br />THAN 30 SF <br />o ALL DOORS LEADING TO THE BATHROOM INCLUDING PRIVATE WATER CLOSET DOORS SHALL MEET THIS <br />— TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMICIDES AND A CERTIFICATE OF COMPLIANCE <br />o THE HEIGHT IS MEASURED FROM THE TOP OF THE CEILING FRAMING MEMBERS TO THE BOTTOM OF <br />REQUIREMENT. <br />TM P <br />It G <br />SHALL BE ISSUED TO THE BUILDING DEPARTMENT <br />— SOIL TREATMENT, BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD ARE ACCEPTABLE FORMS OF <br />THE ROOF FRAMING MEMBERS <br />o MIN. ATTIC ACCESS SIZE IS TO BE 22"x30" WITH 30" OF UNOBSTRUCTED HEADROOM IN THE ATTIC <br />o CLEAR OPENING CAN BE ACHIEVED WITH A 2/8 SWING DOOR OPENED AT 90 DEGREES OR A 2/6 <br />PACKET DOOR <br />tAw!lk <br />u r o ul.. <br />TREATMENT <br />SPACE <br />SITE ADDRESS <br />— INSPECTION FOR TERMITES <br />FIRE—RESISTANT CONSTRUCTION <br />— BUILDINGS SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION. THE ADDRESS SHALL BE NO <br />o PROVIDE 6" CLEARANCE FROM GRADE WITH EXTERIOR WOOD FRAMED WALLS <br />— DOORS FROM GARAGE TO THE RESIDENCE SHALL BE SOLID WOOD OF NOT LESS THAN 1 3/8' IN <br />LESS THAN 4" IN HEIGHT AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY <br />THICKNESS, SOLID OR HONEYCOMB —CORE STEEL DOOR NOT LESS THAN 1 3/8" IN THICKNESS OR <br />■ 4" CLEARANCE REQUIRED AT GARAGES AND PORCHES <br />A 20—MIN. FIRE —RATED DOOR <br />GUARDS AND WINDOW FALL PROTECTION <br />— DUCTS IN THE GARAGE AND DUCTS PENETRATING WALLS OR CEILINGS SEPARATING THE DWELLING FROM <br />— GUARDS SHALL BE PROVIDED WHEN WALKING SURFACES ARE LOCATED MORE THAN 30" ABOVE <br />THE GARAGE SHALL BE CONSTRUCTED IN ACCORDANCE WITH R302.5.3 <br />GRADE (WITHIN 24" HORIZONTALLY) OR A.F.F. <br />EXTERIOR <br />— 1h' GYP. BOARD SHALL BE INSTALLED ON GARAGE SIDE OF WALLS ABUTTING THE RESIDENCE AND GARAGE <br />— WATER RESISTANCE <br />CEILING WITHOUT HABITABLE ROOMS ABOVE <br />—GUARDS SHALL BE MIN. 36" <br />o EXCEPTION: 34" IS ALLOWED IF THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDE <br />o THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT <br />— 5/8' GYP. BOARD SHALL BE INSTALLED ON GARAGE CEILING W/ HABITABLE ROOMS ABOVE <br />OF THE STAIRS <br />PREVENTS THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A <br />— �' GYP. BOARD SHALL BE INSTALLED UNDER STAIRS FOR ENCLOSED ACCESSIBLE SPACES <br />— GUARDRAILS SHALL NOT INCLUDE OPENINGS THAT WILL ALLOW THE PASSAGE OF A 4" SPHERE <br />WATER—RESISTANT BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY R703.2 AND A MEANS <br />OF DRAINING TO THE EXTERIOR WATER THAT ENTERS THE ASSEMBLY. <br />— FIREBLOCKING SHALL BE INSTALLED PER R302.11 <br />— WINDOWS WHERE THE TOP OF THE SILL IS LESS THAN 24" A.F.F. AND GREATER THAN 72" ABOVE FINISHED <br />■ THIS IS NOT REQUIRED OVER CMU <br />— DRAFTSTOPPING SHALL BE INSTALLED PER R302.12 AND SHALL NOT EXCEED 1,000 SF. DRAFTSTOPPING <br />GRADE OF OTHER SURFACE SHALL HAVE A WINDOW OPENING CONTROL DEVICE INSTALLED <br />— FLASHING <br />SHALL DIVIDE THE SPACE IN APPROXIMATELY EQUAL AREAS <br />STAIRS <br />o APPROVED CORROSION RESISTANT FLASHING SHALL BE INSTALLED IN A SHINGLE FASHION PER <br />— MIN. CLEAR WIDTH 36" <br />R703.4 <br />WINDOWS/DOORS <br />o HANDRAILS SHALL NOT PROJECT MORE THAN 4 �" ON EITHER SIDE OF THE STAIRWAY <br />— EXTERIOR PLASTER <br />— FIELD SHALL VERIFY ALL WINDOW/DOOR ROUGH OPENINGS <br />— MIN. HEADROOM 6'-8" <br />o EXTERIOR PLASTER SHALL BE INSTALLED IN COMPLIANCE WITH ASTM C926, ASTM C1063 AND R703.7 <br />— PROVIDE EMERGENCY ESCAPE AND RESCUE WINDOW OR DOOR IN ALL BEDROOMS PER R310 <br />— MAX. RISE 7-3/4" <br />— LATH <br />o (*) DENOTES WINDOW SHALL COMPLY WITH EMERGENCY ESCAPE AND RESCUE (EERO) REQUIREMENTS <br />— MIN. TREAD DEPTH 10" <br />o LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION RESISTANT MATERIALS. EXPANDED METAL <br />o OPENINGS SHALL NOT BE LESS THAN 5.7 SF WITH A NET CLEAR OPENING OF MIN. 24" H AND <br />OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 M" LONG, 11 GAGE NAILS HAVING <br />MIN. 20" D <br />— HANDRAILS <br />A 7/16" HEAD, OR 7/8" LONG, 16 GAGE STAPLES, SPACE NOT MORE THAN 6" INTO FRAMING <br />o EERO WINDOW SILLS SHALL BE INSTALLED NO MORE THAN 44" A.F.F. <br />o 34"-38" ABOVE SLOPE PLANE <br />MEMBERS <br />0 HANDRAILS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT ON STAIRWAYS OF MORE <br />— ONE EGRESS DOOR SHALL BE PROVIDED PER DWELLING UNIT WITH A CONTINUOUS AND UNOBSTRUCTED <br />THAN FOUR RISERS <br />o WEEP SCREEDS, A minimum 0.019—inch (0.5 mm) (No. 26 galvanized sheet gage), <br />PATH WITHOUT GOING THROUGH A GARAGE <br />corrosion —resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of 3 <br />0 1 1/"-2" GRIP SIZE OR GRASPABLE FINGER RECESS <br />inches (89 mm) shall be provided at or below the foundation plate line on exterior stud walls in accordance <br />o MIN. CLEAR WIDTH 32" WHEN OPEN AT 90 DEGREES <br />with ASTM C926. The weep screed shall be placed not less than 4 inches (102 mm) above the earth or 2 <br />o MIN. HEIGHT 78" <br />ELECTRICAL <br />inches (51 mm) above paved areas and shall be of a type that will allow trapped water to drain to the <br />o FINISHED FLOOR SHALL BE MAX. 1 1/2' BELOW TOP OF THRESHOLD <br />— SMOKE ALARMS COMPLYING WITH NFPA 72 SHALL BE INSTALLED: <br />exterior of the building. The weather —resistant barrier shall lap the attachment flange. The exterior lath <br />shall cover and terminate on the attachment flange of the weep screed. <br />o PORCH SHALL BE MAX. 7-3/4" BELOW TOP OF THRESHOLD FOR IN —SWING DOORS <br />o IN EACH SLEEPING ROOM <br />— SIDING <br />— OPENINGS SHALL BE PROTECTED IN WIND —BORN DEBRIS AREAS IN ACCORDANCE WITH R301.2.1.2 <br />o OUTSIDE EACH SLEEPING ROOM <br />o FIBER —CEMENT SIDING IS TO BE INSTALLED IN ACCORDANCE WITH ASTM C1186 AND R703.10 <br />— TEMPERED GLASS SHALL BE INSTALLED WITH THE FOLLOWING <br />o ON EACH ADDITIONAL STORY <br />— MASONRY <br />o FIXED AND OPERABLE PANELS IN DOORS <br />o CANNOT BE INSTALLED WITHIN 3' HORIZONTALLY OF A BATHROOM THAT CONTAINS A BATHTUB OR <br />o BRICK IS TO BE INSTALLED PER R703.8 <br />GLAZING WITHIN 24' OF EITHER SIDE OF DOOR IN THE PLANE OF THE DOOR IN A CLOSED <br />SHOWER <br />o ADHERED MASONRY IS TO BE INSTALLED PER R703.12 <br />POSITION <br />— SMOKE ALARMS SHALL BE HARD —WIRED W/ BATTERY BACKUP AND INTERCONNECTED IN SUCH A MANNER <br />■ GLAZING IS ON A WALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION <br />THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL ALARMS <br />ROOFING <br />AND WITHIN 24" OF THE HINGE SIDE OF AN IN —SWING DOOR. <br />— CARBON MONOXIDE ALARMS ARE REQUIRED TO BE INSTALLED WITHIN 10' OF ALL BEDROOMS <br />— UNDERLAYMENT R905.1.1 <br />o WINDOWS <br />o COMBINATION SMOKE/CARBON MONOXIDE ALARMS ARE PERMITTED <br />o Unless otherwise noted underlayment for asphalt shingles, metal roof shingles, mineral —surfaced roll <br />GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING <br />— THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE <br />roofing, slate and slate —type shingles, wood shingles, wood shakes and metal roof panels shall <br />CONDITIONS SHALL BE CONSIDERED TO BE A HAZARDOUS LOCATION: <br />OF THE GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH MOTOR <br />conform to the applicable standards listed in this chapter. Underlayment materials required to <br />• WHEN EXPOSED AREA IS OVER 9 SF <br />VEHICLE SPACE <br />comply with ASTM D226, D1970, D4869 and D6757 shall bear a label indicating compliance to the <br />standard designation and, if applicable, type classification indicated in Table R905.1.1. Underlayment <br />• BOTTOM EDGE OF GLAZING IS LESS THAN 18" A.F.F. <br />— GROUND —FAULT CIRCUIT PROTECTION; ALL 120V SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED <br />shall be applied and attached in accordance with Table R905.1.1. <br />• THE TOP EDGE OF THE GLAZING IS MORE THAN 36 INCHES (914 MM) ABOVE THE FLOOR; <br />OUTDOORS, IN BATHROOMS, IN KITCHENS, GARAGES, LAUNDRY AND AT DISHWASHER SHALL HAVE GFCI <br />AND <br />CIRCUIT BREAKERS OR RECEPTACLES <br />■ Exception: A reinforced synthetic underlayment that is approved as an alternate to <br />• ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES (914 MM), MEASURED <br />— BRANCH CIRCUITS THAT SUPPLY 120—VOLT, SINGLE PHASE, 15 & 20 AMP OUTLETS INSTALLED IN <br />KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS., LIBRARIES, DENS, BEDROOMS, <br />underlayment complying with ASTM D226 Type II and having a minimum tear strength in <br />HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING <br />SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS <br />accordance with ASTM D1970 or ASTM D4533 of 20 pounds shall be permitted. This <br />o WINDOWS ADJACENT TO THE BOTTOM STAIR LANDING <br />SHALL BE PROTECTED WITH ARC —FAULT CIRCUIT —INTERRUPTER PROTECTION PER FBCR E3902.16 AND <br />underlayment shall be installed and attached in accordance with the underlayment attachment <br />■ WHEN BOTTOM EDGE OF GLAZING IS LESS THAN 36" ABOVE THE PLANE OF THE WALKING <br />SHALL BE LISTED AS TAMPER —RESISTANT <br />methods of Table R905.1.1 for the applicable roof covering and slope, except metal cap nails <br />shall be required where the ultimate design wind speed, equals or exceeds 150 mph. <br />SURFACE <br />— NOT LESS THAN 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE <br />■ WHEN GLAZING IS WITHIN 60' OF BOTTOM STAIR LANDING <br />HIGH —EFFICACY LAMPS OR NOT LESS THAN 75 PERCENT OF THE PERMANENTLY INSTALLED LIGHTING <br />— FLASHING R903.2 <br />FIXTURES SHALL CONTAIN ONLY HIGH —EFFICACY LAMPS <br />o Flashings shall be used to seal roofing systems, where the system is interrupted or terminated and <br />o WET AREAS <br />shall be installed in a manner that prevents moisture from entering the wall and roof through <br />■ GLAZING IN WALLS OR ENCLOSURES CONTAINING OR FACING HOT <br />joints in copings, through moisture permeable materials and at intersections with parapet walls and <br />TUBS, SPAS, BATHTUBS, SHOWERS OR SWIMMING POOLS SHALL BE TEMPERED IF SILL HEIGHT IS <br />other penetrations through the roof plane. <br />LESS THAN 60" A.F.F., MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. <br />— ASPHALT SHINGLES SHALL BE INSTALLED PER R905.2 <br />■ SHOWER AND/OR TUB ENCLOSURES SHALL BE TEMPERED <br />— CLAY AND CONCRETE TILE SHALL BE INSTALLED PER R905.3 <br />WOOD <br />— METAL ROOF SHINGLES SHALL BE INSTALLED PER R905.3.8 <br />— ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE —PRESERVATIVE —TREATED WOOD <br />INSULATION <br />VENTILATION / ATTIC ACCESS <br />— INSULATION SHALL BE INSTALLED PER APPROVED LOT SPECIFIC ENERGY CALCULATIONS <br />— MIN. NET FREE VENTILATION SHALL BE 1 /150 OF THE AREA OF VENTED SPACE WHEN USING SOFFIT <br />— INSULATE, THERMO—PLY AND SEAL AREAS BEHIND TUBS OR SHOWERS ON EXTERIOR WALLS <br />VENTS ONLY PER R806.2 <br />— INSTALL WOOD SHEATHING OR THERMO—PLY ON ATTIC SIDE WHEN CONDITIONED SPACE ABUTS <br />— MIN. NET FREE VENTILATION SHALL BE 1 /300 OF THE AREA OF VENTED SPACE WHEN USING A <br />UNCONDITIONED ATTIC SPACE TO CREATE A 6—SIDED INSULATION ASSEMBLY <br />c3 <br />CV <br />2 <br />C, <br />O <br />U <br />0 <br />Q <br />O <br />Mod <br />� <br />•� <br />o <br />� <br />0 <br />Cn <br />.00 <br />Q <br />� <br />iN <br />o <br />N <br />cr <br />c!44 <br />c� <br />0 <br />bb <br />N <br />c <br />&PulteGroup- <br />PRODUCT MANAGER <br />RELEASE <br />DATE: xx /xx /xxxx <br />PROJECT TYPE I <br />Sinele Family <br />SPECIFICATION LEVEL I <br />Pulte <br />PLAN NAME <br />Hi h ate <br />NPC CHI NU9RER <br />2811.520 <br />SHEET <br />GO.02 <br />