My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6733 Shelby Lynn Way (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6733 Shelby Lynn Way (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:48:07 AM
Creation date
2/28/2025 8:13:50 AM
Metadata
Fields
Template:
Building Plans
Street #
6733
Location
Shelby Lynn Way
Contractor
KHFO LLC
Building Plans - Permit #
2972
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
O <br />ROOF PLAN <br />SCALE: 1 /4"=1'-0" <br />ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />2403 SQ. FT. <br />1 153 SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />461 SQ. IN. <br />UPPER VENT 50% NET VENT MAX. <br />577 SQ. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />4 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />552 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />601 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF.1 <br />92 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />w <br />Lu <br />�00� } <br />>oCQO <br />UJI I- <br />cnUww <br />Q�w�. <br />3E <br />:D <br />Y O I- z <br />,dLLOOC/) <br />Zzz~'Z <br />LA J Q J <br />w n- 2 Iz �- <br />�ZLL 2U_) <br />H Q z <br />cz-� <br />cz C <br />r` <br />O � <br />Q <br />Q <br />2 <br />0 <br />0 <br />U <br />o <br />a <br />O <br />O <br />i� <br />z <br />0 <br />a <br />D <br />A <br />o_ <br />t <br />cn <br />w <br />0 <br />tn <br />o� <br />� <br />A <br />O <br />a <br />a <br />a <br />a <br />a <br />wti . <br />COMMUNITY: <br />UNKS @ CALUSA SPRINGS <br />PLAN # 6101 <br />RELEASED: 9/23/21 <br />SHEET <br />A3 . I <br />z <br />11 <br />D <br />z <br />D <br />z <br />L <br />Rd <br />z <br />z <br />M <br />z <br />g <br />3- <br />
The URL can be used to link to this page
Your browser does not support the video tag.