My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6733 Shelby Lynn Way (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6733 Shelby Lynn Way (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:48:07 AM
Creation date
2/28/2025 8:13:50 AM
Metadata
Fields
Template:
Building Plans
Street #
6733
Location
Shelby Lynn Way
Contractor
KHFO LLC
Building Plans - Permit #
2972
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
91 <br />INSULATION PER - <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. - <br />1 x PT DRAPE BLKG - <br />ABOVE WINDOWS 1/2" <br />G.W.B. <br />WINDOW PER PLAN <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @a 24" O.C. <br />BASE BOARD <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. w/ALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />PRECAST WIN. SILL <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL @ WINDOW <br />SCALE: 1/2" = 1'-O" <br />4 <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />'GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR- <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GRADE I I ', <br />GYPSUM <br />BOARD Z <br />n <br />3 1/2" fr <br />Lu <br />GARAGE 0- <br />ELECTRICAL M <br />PANEL <br />00 <br />CONCRETE `V <br />CURB REFER <br />TO PLANS <br />GYPSUM - <br />BOARD <br />.1' GYPSUM <br />BOARD <br />NICHE FOR <br />ELECTRICP <br />PANEL & <br />WIRING <br />ELECTRICP <br />PANEL <br />EXTERIOR- <br />CMU BLOC <br />WALL <br />CONCRETE <br />CURB REFS <br />TO PLANS <br />CONCRETE - <br />SLAB ON <br />GRADE AT <br />GARAGE <br />FLOOR <br />12 <br />SEE ROOF <br />PLAN <br />1/2" (MIN.) -1 <br />CLG. BD. <br />(8" TYPE 'X' GYP. BD. <br />TO BE PROVIDED <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />GARAGE SLAB, <br />SEE STRUCTURAL <br />PLANS <br />SLOPE <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. WALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />DRIVEWAY PER COMMUNITY <br />4" SPECS <br />0'-0" <br />SLOPE FIN. FL. <br />`—FOUNDATION <br />M PER STRUCTURAL DRAWINGS <br />WALL SECTION C@ GARAGE DOOR <br />SCALE: 1/2" = V-0" <br />ATTIC <br />FLOOR <br />REFER <br />OR SECOND <br />LIVING SPACE <br />TO PLANS <br />T.O. M <br />Z <br />Q <br />d <br />� <br />w <br />d <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L I -----JI <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />N <br />- <br />N <br />L <br />L <br />:R <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />W <br />} 2 � <br />0 0 1- <br />} <br />>oWCQO <br />WC)I- <br />u)UWw <br />Q W F- <br />2 � J <br />cr Ir <br />Y Q I- z <br />06ILOOC/) <br />zzz�z <br />J <br />°C:5¢<- <br />W IIL 2 Er D- <br />Z) z LL w <br />�F-QZ❑ <br />a' 0 � <br />ccI-- <br />O <br />� Q <br />Q <br />0 <br />0 <br />U <br />0 <br />co <br />"row <br />cn <br />z <br />0 <br />0 <br />= <br />u <br />w <br />w <br />i=i <br />a (n <br />mm.. <br />a <br />cn <br />Z <br />0 <br />a, <br />O_ <br />r <br />w <br />U) <br />W <br />U) <br />oa <br />� <br />O <br />1%Z <br />aaaaa <br />COMMUNITY: <br />UNKS @ CALUSA <br />PLAN # 6101 <br />RELEASED: 9/23121 <br />SHEET <br />A5.2 <br />