Laserfiche WebLink
10 <br />nl <br />N <br />v <br />Co <br />N <br />d <br />in <br />o <br />v <br />N <br />w <br />03 <br />o� <br />C) <br />FLORIDIA HOSPITA <br />Z PHYRHI <br />S <br />V <br />NEti fz_" -URGE CAN S <br />12 "aks 1\4edical Office 113ixildirig <br />6748 Gall Boulevard <br />Ze h rhills FL 335411 <br />p Y <br />PROJECT TEAM DIRECTORY <br />SYMBOLS AND <br />MATERIALS <br />INDEX <br />OF DRAWINGS <br />NOTE: The symbols here are specific to the Architectural Drawings <br />as a whole. <br />A0.0 Cover <br />Sheet <br />The LJfe Safety, Reflected Ceiling Plan and Roof Plan respectively <br />Include supplementary legends <br />OWNERand <br />drawing notes specific to those sheets. Refer to other disciplines for additional symbols. <br />ARCHITECTURAL <br />Florida Hospital Zephyrhills <br />AO <br />WINDOW TYPE <br />� <br />EARTH <br />SP.I <br />Site Plan <br />7050 Gall Boulevard <br />� <br />ELEVATION BENCHMARK <br />GRANULAR FILL <br />A1.0 <br />A l I <br />Life Safety Floor Plan <br />Demolition Plan <br />Zephyrhills, Florida 33541 <br />0 <br />REVISION AND NUMBER <br />METAL <br />, <br />A2.0 <br />Floor Plan <br />Phone: (813) 788-0411 <br />A2.1 <br />Reflected Ceiling Plan <br />C.J.D <br />CONTROL JOINT <br />® <br />FINISH WOOD <br />A2.3 <br />Finishes Plan <br />A3.0 <br />Enlarge Plans, Interior Elevations and Sections <br />ARCHITECT <br />DOOR AND FRAME <br />WITH DOOR NUMBER <br />STUCCO OR GYPSUM BOARD <br />A5.0 <br />Schedules and Details <br />0 <br />® <br />CONCRETE OR GRAVEL <br />Burt Hill / Pollock Krieg Architects, Inc. <br />=zr/� <br />EXISTING DOOR <br />PLUMBING <br />METAL STUD WALL <br />CONCRETE MASONRY UNIT (CMU) <br />8250 College Parkway, Suite 203 <br />MASONRY WALL <br />PLYWOOD <br />P0.1 <br />Plumbing Spec's, Legend, Schedules and Drawing List <br />Fort Myers Florida 33919 <br />PLO <br />Underground Plan - Demolition - Plumbing <br />Phone: (239) 4 8 2 - 4 7 61 <br />EVALUATION <br />208 <br />� <br />ROOM NAME AND NUMBER <br />ACOUSTIC CEILING TILE <br />P1.1 <br />P2.0 <br />First Floor Plan - Demolition - Plumbing <br />Underground Plan -New Construction -Plumbing <br />Please be advised this review of plans submitted is a <br />cursory review to assist the contractor in compliance with <br />ry p <br />Fax: (239) 4 8 2 - 0 2 6 5 <br />WALL TYPE <br />® <br />BATT OR SEMI -RIGID INSULATION <br />P2.1 <br />First Floor Plan - New Construction - Plumbing <br />applicable fire safety codes. This review is not intended <br />to be a final approval of the submitted plans. It is the <br />contractors sole responsibility to ensure that the plans are in <br />BUILDING SECTION <br />RIGID INSULATION <br />complete compliun(;e with all applicable NFPA codes and <br />local ordinances. In the event that further examination or <br />SECTION OR DETAIL <br />MECHANICAL <br />site inspection reveals areas of non-compliance, it shall be <br />MEPENGINEER <br />9' <br />ELEVATION <br />ROUGH WOOD FRAMING OR BLOCKING <br />M0.1 <br />HVAC Legend Schedules and Drawing Index <br />the contractor's sole responsibility, at their sole expense to <br />bring those areas in compliance. The Gity assumes no <br />Smith Seickman Reid, Inc. <br />® <br />INTERIOR ELEVATION <br />M0.2 <br />M0.3 <br />HVAC Riser <br />HVAC Specifications <br />responsibility for the contractor's failure to be in compliance <br />with all applicable NFPA Codes and local ordinances. <br />Ta ALL <br />600 West Hillsboro, Suite 300 <br />pLLW©RKgKALLCO OLRIDA6 <br />VAI�,1NGCODMVL <br />CCODEA <br />M1.1 <br />M2.1 <br />First Floor Plan - Demolition - HVAC <br />First Floor Plan -New Construction -HVAC <br />Deerfield Beach Florida 343441 <br />NORTH ARROW <br />CODE, NATIONALELF O <br />� � - q�!* <br />i <br />M5.1 <br />HVAC Details <br />Phone: (954) 421-1260 <br />M5.2 <br />HVAC Details <br />Fax: (954) 421-1466 <br />+"M=D PLANS M BEEN REVIEW <br />OFF <br />XT <br />fi11'�_--% <br />aY ZEPHYRHILL fS <br />Date: — <br />R-6+/'1i�wp <br />FIRE PROTECTION <br />Seal 5ke 71t <br />6 ? <br />FPO.1 <br />FPI.I <br />Fire Protection Specs Legend Schedules and Drawing <br />First Floor <br />Index <br />4P 14k <br />Plan - Demolition - Fire Protection <br />VICINITY MAP <br />FP2.1 <br />First Floor Plan - New Construction - Fire Protection�dY P"�v��s <br />FP5.1 <br />Fire Protection Details <br />ND S� )r?-e <br />l <br />ELECTRICAL <br />E0.1 <br />Electrical Legend, Schedules and Drawing Index <br />�N <br />E1.1 <br />First Floor Plan - Demolition - Electrical <br />Industry standards (I.e. ASTM, ANSI, etc.) SHALL HAVE THE SAME FORCE AND EFFECT <br />E2.1 <br />First Floor Plan -New Construction -Lighting <br />on performance of work as If copies were directly Inserted Into the Contract Documents or bound and <br />published therewith. Comply with standards In effect as of the date of the Contract Documents, <br />t <br />E3.1 <br />First Floor Plan New Construction -Power & Systems <br />y <br />unless otherwise note or required by authorities having Jurisdiction. <br />E4.1 <br />Electrical Riser Diagrams <br />E5.1 <br />Electrical Specifications <br />CODES All work shall conform to the following codes and ordinances: <br />re>V -. <br />2007 Florlda Building Code, with 2009 amendments <br />2007 Florida Plumbing Code, with 2009 amendments <br />2007 Florida Fuel Gas Code, with 2009 amendments <br />2007 Florida Mechanical Code, with 2009 amendments <br />- 2007 Florida Fire Prevention Code <br />Local Codes and Ordinances where applicable and flood damage prevention ordinances <br />2006 NFPA 101 Life Safety Coae <br />�°� <br />z Project <br />a <br />� � f .met• <br />�:..�.'� <br />�= <br />.. µz <br />G <br />Project No. 11006.00 <br />AOOO <br />02011 BH/PK Architects, Inc. <br />