My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6748 Gall Blvd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
6748 Gall Blvd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:31:31 PM
Creation date
2/28/2025 8:14:06 AM
Metadata
Fields
Template:
Building Plans
Street #
6748
Location
Gall Blvd
Contractor
Sealander Construction SVC Inc
Building Plans - Permit #
11946
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
................f,...... <br />i <br />GENERAL NOTES: <br />FIRST FLOOR PLAN - NEW CONSTRUCTION - FIRE PROTECTION <br />111111111 1 0 - (I <br />1. CONTRACTOR SHALL PATCH WALLS, FLOORS, AND CEILINGS TO MATCH <br />EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF FIRE PROTECTION <br />SYSTEMS. COORDINATE WITH ARCHITECTURAL DRAWINGS. <br />2. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. <br />A. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCRIBED BY OWNER. <br />B. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT <br />BY THE OWNER. <br />C. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION <br />OF SHUTDOWNS REQUIRED. <br />3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, <br />PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. <br />4. CONTRACTOR SHALL COORDINATE TIMING, DURATION AND AREAS AFFECTED BY SHUTDOWNS WITH <br />OWNER IN ORDER TO FACILITATE REQUIRED FIRE WATCH, <br />5. CONTRACTOR SHALL COORDINATE NEW SPRINKLER HEAD LOCATIONS WITH CEILING GRID AND CEILING <br />MOUNTED DEVICES (LIGHTS, DIFFUSERS, SMOKE DETECTORS, ETC.). <br />6. CONTRACTOR SHALL RAISE EXISTING SPRINKLER PIPING WITHIN SCOPE AND PROVIDE WITH NEW <br />FITTINGS AND HANGERS. <br />7. SPRINKLER HEADS SHALL BE A MINIMUM OF 12" AWAY FROM HVAC DIFFUSERS. <br />8. CONTRACTOR SHALL FIELD VERIFY THAT THE EXISTING 1" SPRINKLER BRANCH PIPING DOESN'T <br />HAVE MORE THAN 2 SPRINKLERS. IF THE 1' BRANCH LINE EXCEEDS 2 SPRINKLERS THEN <br />A NEW V BRANCH SHALL BE RUN BACK TO THE EXISTING SPRINKLER MAINS. <br />KEYED NOTES: <br />OEXISTING SPRINKLER PIPING SHALL BE REWORKED AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION <br />PLAN. EXISTING SEMI -RECESSED QUICK RESPONSE SPRINKLER HEADS SHALL BE REMOVED AND REPLACED <br />WITH NEW QUICK RESPONSE SPRINKLER HEADS WITH 1" ARMOVER PER NFPA 13. <br />l) <br />O <br />.......................................... <br />NEW CONSTRUCTION LEGEND <br />SYMBOL <br />DESCRIPTION <br />--� <br />PIPE NEW SPRINKLER HEADS FROM EXISTING LOCATION <br />0 <br />EXISTING SPRINKLER HEADS TO REMAIN <br />EXISTING TO REMAIN <br />NEW CONSTRUCTION <br />—� <br />CONNECT TO EXIST. AT THIS POINT <br />x <br />ATE nF <br />Smith <br />Seckman <br />Reid, Inc. <br />600 West Hillsboro, Suite 300 <br />Deerfield Beach, FL 33441 <br />(954) 421-1260 <br />FAX: (954) 421-1466 <br />www.ssr-inc.com <br />Firm Certification - EB-0000857 <br />Dennis Davie PF. - 58588 <br />John E. Moulder PE - 33200 <br />SSR JOB # 1137001.0 <br />k2 <br />CID <br />�o <br />o <br />N � <br />—Qd ty c�D 6 <br />T_- <br />0 <br />ti d o <br />q <br />L <br />N <br />O a . <br />�--� Q. <br />U � <br />i O <br />O = <br />a- M <br />(D <br />l 1__ _O <br />� I <br />O <br />4--1 � <br />L � <br />Cn <br />O m <br />U (a) <br />LF— <br />(a) ' <br />z 0 <br />I (� <br />_U <br />CIO <br />L <br />O (J7 <br />O "e <br />IL (13 <br />N O <br />U_ CV <br />T <br />Project No, 11006.00 <br />FP2.1 <br />D2011 UHIPK Archiiects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.