My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6750 Shelby Lynn Way
Zephyrhills
>
Building Department
>
Building Plans
>
6750 Shelby Lynn Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:29:54 PM
Creation date
2/28/2025 8:14:24 AM
Metadata
Fields
Template:
Building Plans
Street #
6750
Location
Shelby Lynn Way
Contractor
KHFO LLC
Building Plans - Permit #
2512
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3-BULB <br />HALL <br />BATH <br />I II <br />110V <br />L--GEV=lg <br />L------ u <br />F - - 220V - n <br />I <br />GFI Q <br />I II <br />I Al IAIIIRV InDT n II <br />ADD BLOCKING <br />LOFT <br />ADD BLOCKING <br />BEDROOM 2 <br />ADD BLOCKING <br />BEDROOM 3 <br />I I <br />I <br />� I <br />L_...._. — ..._....-........_..._... ___I <br />SECOND FLOOR ELECTRICAL PLAN <br />SCALE: 1/4"=1'-0" <br />ADD BLOCKING <br />BEDROOM 4 <br />-11 <br />2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />0 OR <br />2-4/0 ALUMINUM <br />200 AMP 42 <br />METER 1-3/0 ALUMINUM <br />CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. <br />BREAKER <br />PVC 1 /2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />TO FP� <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />GREAT ROOM <br />)ATA ADD <br />TV] BLOCKING <br />I <br />I <br />I , > (n" - -N, <br />X STE <br />P BATH <br />F L <br />EXTRA SUITE <br />ADD BLOCKING <br />3-BULB <br />PATIO <br />DINING AREA <br />ADD <br />BLOCKING <br />T] LI jHj @ <br />I I I 1 1 <br />I I I I I <br />UNDER -SINK <br />SWITCH FOR <br />DISPOSAL <br />KITCHEN CH% <br />w <br />Q O <br />C <br />I I <br />I <br />I <br />I I <br />CH GFb <br />I I <br />_� <br />1OPT. <br />u REF. �Ep <br />II <br />II I <br />PTRY <br />_I I Inl' <br />WH <br />O <br />2MV=( <br />2 CAR GARAGE <br />IRRIGATION <br />FI42"AFF TIMER GFI <br />CM PREWIRE FOR o <br />GARAGE DOOR N <br />FOYER OPENER ELECTRICAL <br />GFI PANEL ON 2X4 <br />WALL (V.I.F.) <br />--------------------------- ------------,� <br />M <br />I <br />.B. FOR <br />rHIMESEN RY <br />I I <br />I I <br />I P I <br />I I <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1/4"=1'-0" <br />HOOD <br />RANGE <br />WH <br />DISCONNECT <br />FIELD <br />VERIFY <br />METER <br />ELECTRICAL KEY <br />b� DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />�- KEYLESS LIGHT FIXTURE <br />-� CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />ow VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />f� EXHAUST FAN <br />p EXHAUST FAN/LIGHT COMBINATION <br />© CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />IQ TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />01 ELECTRIC METER <br />= ELECTRIC PANEL <br />--WAL DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I-- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />Lu <br />p J � W <br />wz0� <br />w <br />LuZ0 <br />>OC¢0 <br />W p H <br />Q ? 3: W <br />W <br />ILU)Wg <br />� cc <br />°2SZZF_W <br />CC i Q J <br />Lu a 2 <br />00 <br />= Z IL U) <br />�F-¢Zp <br />CZ''� <br />CZ <br />c coc <br />t\ <br />H <br />0 � <br />Q <br />a <br />z <br />ova <br />0 <br />O <br />U < <br />U <br />w U. <br />(n ce <br />0) <br />Z U <br />w <br />w <br />O(j) <br />x <br />M M <br />0 <br />o <br />w <br />LL <br />w <br />0 <br />E <br />o� <br />W <br />G <br />U) <br />04 <br />r <br />16Zaaaaa <br />o <br />COMMUNITY: <br />UNKS @ CALUSA SPRINff <br />PLAN # 6102 <br />RELEASED: 7/14/21 <br />SHEET <br />El*l <br />
The URL can be used to link to this page
Your browser does not support the video tag.