2" PVC CONDUIT <br />2-2/0 COPPER <br />1-1/0 COPPER <br />OR <br />klij 2-4/0 ALUMINUM <br />150 AMP 4: <br />mm 1-3/0 ALUMINUM <br />CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. <br />BREAKER <br />PVC 1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />T�;P <br />I <br />r; <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />w <br />OUTLET FOR <br />U/C REF. <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-0" <br />A/C <br />DISCONNECT <br />WP/ GFid <br />ELECTRICAL <br />METER (V.I.F.) <br />ELECTRICAL KEY <br />0 DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />THREE-WAY SWITCH <br />4 FOUR-WAY SWITCH <br />-¢ KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />or VAPOR PROOF LIGHT FIXTURE <br />+m LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />0 EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />® COMBINATION SMOKE / CO2 DETECTOR <br />® SMOKE DETECTOR <br />F4 TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />Do ELECTRIC METER <br />= ELECTRIC PANEL <br />-�+- DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I--- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />w <br />} _ CC <br />GOOF- <br />} <br />� Q O <br />w <br />Q <br />UWw c) <br />< =) -- <br />CC <br />W <br />J U) W <br />5Ircr_M <br />Y O I- Z <br />'6LLOOU) <br />Z Z Z H <br />IrZ_ <br />CLQ�J <br />Ill a 2 cc d <br />�cnp0U <br />= Z LL (A <br />H Q Z <br />� <br />cz''� Q <br />� m <br />cz <br />O �¢ <br />Q <br />O <br />O <br />O <br />U <br />� <br />O <br />Im <br />a <br />O <br />� <br />0 <br />U <br />POEM <br />w <br />a <br />LLL <br />u <br />U) <br />w <br />w <br />w <br />2 <br />a <br />O <br />E <br />cn <br />W <br />G <br />z <br />Z <br />O� <br />�o <br />Z <br />aaaaa <br />COMMUNITY: <br />LINKS AT CALM - <br />SPRINGS <br />PLAN # 6120 <br />RELEASED: 7/2/21 <br />SHEET <br />El,l <br />