2" PVC CONDUIT <br />2-2/0 COPPER <br />O OR COPPER <br />OR <br />2-4/0 ALUMINUM 150 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />PVC 1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />1 <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />FIRST FLOOR ELECTRICAL PLAN <br />ELECTRICAL <br />METER (V.I.F.) <br />ELECTRICAL KEY <br />I DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />Fl GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />s THREE-WAY SWITCH <br />14 FOUR-WAY SWITCH <br />- KEYLESS LIGHT FIXTURE <br />-[ CEILING MOUNTED LED LIGHT FIXTURE <br />- WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />4r VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />4 EXHAUST FAN <br />sf EXHAUST FAN/LIGHT COMBINATION <br />0 CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />cM COMBINATION SMOKE / CO2 DETECTOR <br />so SMOKE DETECTOR <br />i4 TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />(p ELECTRIC METER <br />= ELECTRIC PANEL <br />__mj_ DISCONNECT SWITCH <br />Q JUNCTION BOX <br />/I-- STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42" <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />Ir <br />w <br />> _ <br />�00� <br />>a"-<0 <br />w::)o1-- <br />U) 0 <br />��>a <br />Z)c�� <br />°tfzzpLu <br />i Q <br />2 J <br />wo=Ic <br />�cn000 <br />:Dy:zLL n <br />�I-Q?� <br />Z CZ n <br />a .-. <br />n <br />O <br />� <br />Q <br />0 <br />0 <br />u <br />z <br />0 <br />10° <br />a <br />�o <br />o j <br />J <br />U U <br />0 <br />0-i <br />a <br />I <br />�+r <br />U) <br />w <br />w <br />a U <br />M=Mf <br />(L <br />LL. w <br />w <br />z <br />0 <br />a <br />O_ <br />U) <br />w <br />Uw <br />Oo <br />ia*Z <br />aaaaa <br />COMMUNITY: <br />LINKS @ CALUSA 9PRINGS <br />PLAN # 6101 <br />RELEASED:12/23/21 <br />SHEET <br />E• <br />SCALE: 1 /4"=1'-0" <br />