My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6785 Branham Mill Ct (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6785 Branham Mill Ct (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:32:21 AM
Creation date
2/28/2025 8:15:30 AM
Metadata
Fields
Template:
Building Plans
Street #
6785
Location
Branham Mill Ct
Contractor
KHFO LLC
Building Plans - Permit #
3407
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />12 <br />SEE ROOF <br />PLAN <br />INSULATION PER — <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />ix PT DRAPE BLKG - <br />ABOVE WINDOWS 1/2" <br />G.W.B. <br />WINDOW PER PLAN <br />GYP.BD. <br />WINDOW SILL <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @ 24" O.C. <br />BASE BOARD <br />SEE <br />SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN <br />REFER TO PLANS <br />mm== <br />FINISH PER PLAN <br />- <br />7/8 STUCCO OVER LATH <br />'= <br />W/ 60 MIN. GRADE D PAPER BACKED <br />_ <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />= <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION AS <br />I <br />2X ALUM WRAPPED FASCIA <br />PER SPECS. <br />----- <br />BD. w/ALUM DRIP EDGE <br />PRE-ENGINEERED <br />SOFFIT INSTALLED PER <br />GABLE END ROOF <br />MANUF. SPECS <br />TRUSS - REFER TO <br />2X PT BLOCKING <br />STRUCTURALS <br />HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. <br />MASONRY LINTEL - REFER TO <br />STRUCTURALS <br />TYP. HIPPED PENT <br />ROOF DETAIL <br />SCALE: 1/2" = V-0" <br />1-STORY - MASONRY WALL <br />ROOF SHINGLES OVER <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE 11 OR <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />12 <br />R905.1.1.1 (SEE SHEET CS2) <br />PRE-ENGINEERED ROOF <br />SEE ROOF <br />PLAN <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />STRUCTURAL. <br />TOP OF C.M.U. <br />TOP OF C.M.U. <br />4LV. <br />\qv(REFER TO ELEV.) <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />2x6 ALUM WRAPPED FASCIA <br />BD. w/ALUM DRIP EDGE <br />j <br />EE <br />BD. w/ALUM DRIP EDGE <br />j <br />E V. <br />1/2" (MIN.) <br />---- <br />SOFFIT INSTALLED PER <br />CLG. BD. <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />(I" TYPE'X' GYP. BD. <br />MANUF. SPECS <br />2X PT BLOCKING <br />TO BE PROVIDED <br />2X PT BLOCKING <br />WHEN LIVING SPACE <br />SEE STRUCTURAL <br />IS ABOVE GARAGE) <br />SEE STRUCTURAL <br />PLAN <br />PLAN <br />PRECAST WIN. SILL <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />it 0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL C@ WINDOW <br />SCALE: 1/2" = V-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4 <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />' GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR— <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GYPSUM — <br />GYPSUM <br />BOARD <br />BOARD Z <br />5 <br />11/2" <br />� GYPSUM <br />Ir <br />w <br />GARAGE a <br />BOARD <br />NICHE FOR <br />ELECTRICF <br />PANEL & <br />WIRING <br />- <br />cV <br />ELECTRICAL <br />PANEL <br />ELECTRIC <br />PANEL <br />i <br />cV <br />C° <br />EXTERIOR - <br />co <br />I <br />CMU BLOC <br />WALL <br />N <br />CONCRETE <br />CONCRETE <br />CURB REFER <br />CURB REF! <br />TO PLANS <br />TO PLANS <br />CONCRETE - <br />000000 <br />SLAB ON <br />y�rY <br />GRADE <br />GRADE AT <br />GARAGE <br />FLOOR <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />EXPANSION JOINT <br />GARAGE SLAB, DRIVEWAY PER COMMUNITY <br />SEE STRUCTURAL 4�. SPECS <br />PLANSSSE SSE FIN. <br />lm <br />`-FOUNDATION <br />M PER STRUCTURAL DRAWINGS <br />WALL SECTION @ GARAGE DOOR <br />SCALE: 1/2" = V-0- <br />ATTIC <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1 /2" = V-0" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />cc <br />W <br />Lu <br />wZ0= <br />O } F- <br />> cr < 0 <br />WZ)C)F- <br />w 0 3: w <br />Q = W H <br />m cr <br />� <br />J W W <br />5 cr Iz Er <br />Y O 1- Z <br />,ZLL0_OU) <br />LLI <br />Z Z Z F- Z <br />cr-QJ <br />W Il = cr- a <br />_jcnp0U <br />Z=ZLL U) <br />�1-Q?cz <br />n <br />O <br />.9a <br />Q <br />0 <br />0 <br />ft <br />y <br />U <br />0 <br />j <br />❑ <br />0 <br />U) <br />z <br />0 <br />0 <br />j "mo <br />= <br />u u <br />w <br />w <br />a cn <br />ommm <br />LL <br />U) <br />z <br />0 <br />[L <br />O <br />R <br />lz <br />U) <br />W <br />0 <br />kcfn; <br />aaaaa <br />`SEC 16 2021 <br />COMMUNITY: <br />PLAN # 61 Of <br />RELEASED: 12/23/21 <br />SHEET <br />A5•2 <br />Fm <br />