My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6901 Medical View Ln (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6901 Medical View Ln (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:45:16 AM
Creation date
2/28/2025 8:16:10 AM
Metadata
Fields
Template:
Building Plans
Street #
6901
Location
Medical View Ln
Contractor
Preuse Construction
Building Plans - Permit #
21144
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tI _ 11 1 11 1 1 1 1 1 1 1 <br />PROJECT INFORMATION <br />PROJECT NAME: WATSON CLINIC DERMATOLOGY <br />PROJECT LOCATION: 6901 MEDICAL VIEW LANE <br />ZEPHYERHILLS, FLORIDA <br />ARCHITECT'S PROJECT NUMBER: 1812.01 <br />PROJECT DESCRIPTION <br />INTERIOR RENOVATION TO AN EXISTING SUITE, INCLUDING <br />ARCHITECTURAL, MECHANICAL, PLUMBING & ELECTRICAL. <br />AREA OF WORK: 2,569 SF <br />FLOOD DESIGN DATA: <br />N/A <br />CLADDING DESIGN DATA: <br />NIA <br />CODE REFERENCE <br />Uj;j■_L=Iid9I11*1 <br />FLORIDA BUILDING CODE, SIXTH EDITION 2017 <br />FLORIDA ACCESSIBILITY CODE, SIXTH EDITION 2017 <br />FLORIDA MECHANICAL CODE, SIXTH EDITION 2017 <br />FLORIDA PLUMBING CODE, SIXTH EDITION 2017 <br />FLORIDA BUILDING CODE, SIXTH EDITION 2017 <br />FLORIDA FIRE PREVENTION CODE, FIFTH EDITION 2017 <br />NFPA 70, NATIONAL ELECTRICAL 2014 <br />(EXCEPT ARTICLE 80) <br />OCCUPANCY (FBC CHAPTER 3): <br />BUSINESS - GROUP B <br />TYPE OF CONSTRUCTION (FBC CHAPTER 6): II-B (EXISTING) <br />INTERIOR FINISHES (TABLE 803.91. <br />SYMBOL LEGEND <br />EXIT SIGN WITH BATTERY PACK <br />OFE FIRE EXTINGUISHER & CABINET <br />NOTE: <br />SEE LIGHTING PLAN FOR EMERGENCY LIGHTING FIXTURES. <br />RATED WALLS <br />1 HOUR 1HF -- 1HF 1HF - <br />TRAVEL DISTANCE <br />TRAVEL DISTANCE (TD) <br />TD=100' <br />DIRECTION OF TRAVEL <br />OCCUPANCY <br />EXIT ENCLOSURES <br />CORRIDORS <br />ROOMS AND <br />AND PASSAGEWAYS <br />ENCLOSED SPACES <br />GROUPS <br />CLASS A <br />CLASS B <br />CLASS C <br />MEANS OF EGRESS (FBC CHAPTER 10) <br />POPULATION/ OCCUPANCY LOAD (FROM TABLE 1004.1.2) <br />USE <br />AREA <br />AREA/PERSON <br />OCCUPANTS <br />BUSINESS <br />2,569 SF <br />100 GROSS <br />26 PERSONS <br />TOTAL OCCUPANT LOAD 26 PERSONS <br />ucwr.a �c cn_occ•� <br />(FBC CHAPTER 10) <br />UNSPRINKLED, - "B" OCCUPANCY <br />OCCUPANCY: <br />REQUIRED <br />PROVIDED <br />MAXIMUM TRAVEL <br />200 FT <br />59 FT <br />DISTANCE (TABLE 1017.2) <br />MAXIMUM DEAD-END <br />20 FT <br /><20 FT <br />CORRIDOR (FBC 1018.4) <br />TOTAL # OF BLDG EXITS <br />(SECTION 1021.2) <br />2 PER STORY <br />2 PER STORY <br />COMMON PATH OF EGRESS <br />TRAVEL (SECTION 1014.3, <br />100'-0" <br /><100'-0" <br />EXCEPTION 1) <br />OTHER EGRESS WIDTH PER <br />0.2 <br />34„ <br />LEVEL (SECTION 1005.3.2) <br />26x(0.2)=5.2" <br />MINIMUM CORRIDOR <br />AISLE WIDTH <br />�" <br />54" MIN. <br />(TABLE 1018.2) <br />EXIT PASSAGE WAY FIRE <br />N/A <br />N/A <br />RATING (SECTION 1023.3) <br />MINIMUM CLEAR <br />OPENING OF EXIT <br />32" <br />AT LEAST 34" <br />DOORS (SECTION 1008.1.1) <br />MINIMUM PLUMBING FACILITES (FPC CHAPTER 4) <br />BUSINESS, 26 PERSONS - PER FLOOR (TABLE 403.1) <br />CATEGORY <br />WATER CLOSETS <br />LAVATORIES <br />DRINKING FOUNTAINS <br />OTHER <br />REQUIRED <br />PROVIDED <br />REQUIRED <br />PROVIDED <br />REQUIRED <br />PROVIDED <br />2 <br />2 <br />1 <br />2 <br />1 <br />1 <br />GENERAL NOTES <br />TACTILE SIGNAGE SHALL BE PROVIDED PER LSC101 CH. 7.10.1.3. <br />TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR REQUIRING <br />AN EXIT SIGN. TACTILE SIGNAGE SHALL READ AAS FOLLOWS: EXIT <br />TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1 <br />EXISTING 1-HOUR <br />RATED WALL — <br />TD-40'— — <br />TD = 59' <br />LIFE SAFETY PLAN <br />SCALE: 1/4" =1'-0" <br />585 Main Street, Suite 201 <br />Dunedin, FI 34698 <br />p 727.733.9400 <br />f 727.733.9555 <br />11c. AAC001580 <br />Iunz.Com <br />9 'r" <br />f, <br />r <br />2019 <br />0 <br />0 <br />J <br />0 <br />CQ <br />G <br />LU <br />0 <br />U) <br />17 <br />J <br />I..L� <br />m <br />LU <br />N <br />1 <br />Z <br />0 <br />W <br />REVISION® • • • • • • • • • . <br />REVISIONt .......... -- <br />ISSUED FOR CONSTRUCTION: -- <br />ISSUED FOR PERMIT: 09.05.18 <br />ISSUED FOR BID: -- <br />ISSUED FOR APPROVAL• -- <br />DRAWN BY: M. HACKETT <br />REVIEW BY: J. WAHAM <br />r, <br />r, <br />THE LUNZ GROUP <br />OCOPYRIGHT 2018 ALL RIGHTS RESERVED <br />1812.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.