My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6986 Shelby Lynn Way (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6986 Shelby Lynn Way (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:36:15 AM
Creation date
2/28/2025 8:16:58 AM
Metadata
Fields
Template:
Building Plans
Street #
6986
Location
Shelby Lynn Way
Contractor
KHFO LLC
Building Plans - Permit #
3082
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ej <br />Pi <br />12 <br />SEE ROOF <br />� PLAN <br />INSULATION PER - <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />1 x PT DRAPE BLKG - <br />ABOVE WINDOWS 1/2" <br />G.W.B. <br />WINDOW PER PLAN <br />SOLID SURFACE — <br />CAULKED @ WINDOW <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO ix2 PT. <br />FURRING @ 24" O.C. <br />BASE BOARD <br />SEE <br />SOFFIT AT RAKE (BEYOND) <br />ROOF PLAN <br />REFER TO PLANS <br />. ; <br />FINISH PER PLAN <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION AS <br />2X ALUM WRAPPED FASCIA <br />PER SPECS. ----- <br />BD. WALUM DRIP EDGE <br />PRE-ENGINEERED <br />SOFFIT INSTALLED PER <br />GABLE END ROOF <br />MANUF. SPECS <br />TRUSS - REFER TO <br />2X PT BLOCKING <br />HURRICANE STRAP - REFER TO <br />STRUCTURALS <br />STRUCTURALS <br />1/2" (MIN.) CLG. BD. <br />MASONRY LINTEL - REFER TO <br />STRUCTURALS <br />TYP. HIPPED PENT <br />ROOF DETAIL <br />SCALE: 1/2" = V-0" <br />1-STORY - MASONRY WALL <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II <br />OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED <br />PER <br />R905.1.1.1 (SEE SHEET CS2) <br />OR <br />CONCRETE TILE W/ SELF ADHERED <br />MEMBRANE UNDERLAYMENT <br />60 MIL. OR EQUAL <br />12 <br />I SEE ROO F <br />PRE-ENGINEERED ROOF <br />PLAN <br />P <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />\ HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OIL TOP OF C.M.U. <br />(REFER TO ELEV.) <br />I I <br />2x6 ALUM WRAPPED FASCIA <br />i EE BD. WALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />PRECAST WIN. SILL <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />0'-0" <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 1-STORY WALL C@ WINDOW <br />SCALE: 1/2" = V-0" <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />PROVIDE 2X4— <br />FRAMED <br />ENCLOSURE FOR <br />ELECTRICAL <br />PANEL, FINISH W/ <br />"' GYPSUM <br />BOARD <br />ELECTRIC METER <br />LOCATION - SEE <br />PLANS. VERIFY <br />INSTALLATION IN <br />FIELD <br />STUCCO <br />FINISH <br />EXTERIOR- <br />CMU BLOCK <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE <br />INSTALLED ACCORDING <br />TO ALL APPLICABLE <br />LOCAL, STATE AND <br />NATIONAL CODES. <br />VERIFY PANEL <br />DIMENSIONS PRIOR TO <br />CONSTRUCTION. <br />GYPSUM - <br />GYPSUM <br />BOARD <br />BOARD z <br />3 1/2" it <br />GYPSUM <br />w <br />GARAGE a - <br />BOARD <br />NICHE FOR <br />ELECTRICA <br />PANEL & <br />WIRING <br />N <br />ELECTRICAL M <br />PANEL ELECTRICP <br />PANEL <br />N <br />`° EXTERIOR <br />00 <br />CMU BLOCI <br />WALL <br />N CONCRETE <br />ONCRETE <br />CURB REFER CURB REFS <br />TO PLANS TO PLANS <br />CONCRETE- <br />s. r1 �. > 2`. > SLAB ON <br />GRADE'�.7x GRADE AT <br />GARAGE <br />FLOOR <br />1/2" (MIN.) .J <br />CLG. BD. <br />(t" TYPE'X' GYP. BD. <br />TO BE PROVIDED <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />ROOF SHINGLES OVER <br />TWO LAYERS OF ASTM D226 TYPE II OR <br />SYNTHETIC UNDERLAYMENT COMPLYING <br />WITH ASTM D226 TYPE II INSTALLED PER <br />R905.1.1.1 (SEE SHEET CS2) <br />OR <br />CONCRETE TILE W/ SELF ADHERED <br />MEMBRANE UNDERLAYMENT <br />60 MIL. OR EQUAL <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OL TOP OF C.M.U. <br />(REFER TO ELEV.) <br />2x6 ALUM WRAPPED FASCIA <br />BD. WALUM DRIP EDGE <br />SOFFIT INSTALLED PER <br />MANUF. SPECS <br />2X PT BLOCKING <br />SEE STRUCTURAL <br />PLAN <br />EXPANSION JOINT <br />GARAGE SLAB, DRIVEWAY PER COMMUNITY <br />SEE STRUCTURAL 4 SPECS <br />PLANS OIL <br />SLOPE SLOPE 0 -0" <br />_ _ . FIN. FL. <br />--FOUNDATION <br />M PER STRUCTURAL DRAWINGS <br />WALL SECTION � GARAGE DOOR <br />SCALE: 1/2" = V-0" <br />ATTIC OR SECOND <br />FLOOR LIVING SPACE <br />REFER TO PLANS <br />T.O. M <br />I I <br />I I <br />I <br />I I <br />I I <br />I I <br />I I <br />L-__-_J <br />z <br />a <br />a'w <br />0— <br />7js_111__ <br />EIE <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />N <br />cM <br />°° <br />— <br />Nzo <br />L <br />L <br />- <br />---- <br />1. <br />,1 <br />:R <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = V-0" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />Ir <br />W <br />cr <br />Wz0= <br />O H <br />>oWCa0 <br />w 0 3: w <br />Q=WF- <br />J (n W W <br />YQI-Z <br />LL 0 cn <br />_O <br />z z z F-rr:z <br />J Q � J <br />W C- 2 tr C- <br />Z=ZLL(A <br />H Q Z <br />n <br />N <br />cc <br />n <br />O � <br />Q <br />Q <br />0 <br />0 <br />0 <br />'-j <br />p <br />Im <br />cq <br />00 <br />U <br />w <br />U) <br />0 <br />w <br />� <br />w <br />CL <br />U) <br />m< <br />O_ <br />cn <br />W <br />O <br />z <br />O <br />Ig <br />.Q <br />n <br />C] <br />�Z <br />aaaaa <br />r MAR Q 2 2022 <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6100 <br />RELEASED: 9/30/21 <br />SHEET <br />A562 <br />z <br />T <br />J) <br />z <br />x <br />7) <br />z <br />g <br />7) <br />Ij <br />z <br />Q <br />z <br />7) <br />z <br />g <br />:n <br />Ij <br />_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.