Laserfiche WebLink
2" PVC CONDUIT <br />2-2/0 COPPER <br />O 1-1/0 COPPER <br />OR <br />2-4/0 ALUMINUM 150 AMP 42 <br />METER 1-3/0 ALUMINUM CIRCUIT <br />MAIN <br />CIRCUIT <br />#4 COPPER OR ALUM. BREAKER <br />1/2" PVC <br />CONCRETE ENCASED <br />GROUNDED ELECTRODE <br />a <br />I <br />ELECTRICAL RISER DIAGRAM <br />NOT TO SCALE <br />0 <br />ELECTRICAL <br />METER (V.I.F.) <br />FIRST FLOOR ELECTRICAL PLAN <br />SCALE: 1 /4"=1'-O" <br />f Innw16Irl+T <br />ELECTRICAL KEY <br />k& DUPLEX CONVENIENCE OUTLET <br />WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />220 VOLT OUTLET <br />USB COMBO OUTLET <br />WALL SWITCH <br />9 THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />- KEYLESS LIGHT FIXTURE <br />CEILING MOUNTED LED LIGHT FIXTURE <br />WALL MOUNTED INCANDESCENT LIGHT FIXTURE <br />01 VAPOR PROOF LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />FLUORESCENT LIGHT FIXTURE <br />f� EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® CHIMES (OPTIONAL) <br />p PUSHBUTTON SWITCH (OPTIONAL) <br />COMBINATION SMOKE / CO2 DETECTOR <br />so SMOKE DETECTOR <br />F4 TELEPHONE (OPTIONAL) <br />Q TELEVISION (OPTIONAL) <br />RD ELECTRIC METER <br />s ELECTRIC PANEL <br />­j DISCONNECT SWITCH <br />Q JUNCTION BOX <br />STANDARD ELECTRICAL LINE <br />NOTES: <br />1. PROVIDE AND INSTALL GROUND FAULT <br />CIRCUIT-INTERUPTERS (GFI) AND ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) PER 2017 NEC 210.12 <br />2. UNLESS OTHERWISE INDICATED, INSTALL SWITCHES & <br />RECEPTACLES AT THE FOLLOWING HEIGHTS ABOVE FINISH <br />FLOOR: <br />SWITCHES ........... 42 <br />OUTLETS.............14" <br />ABOVE COUNTER OUTLETS ...... 46" <br />TELEPHONE ......... 14" <br />TELEVISION .......... 14" <br />3. ALL SMOKE DETECTORS SHALL BE HARDWIRED INTO AN <br />ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH <br />A MONITORED BATTERY BACKUP. PROVIDE AND INSTALL <br />LOCALLY CERTIFIED SMOKE DETECTORS. <br />4. OUTLET AND LIGHTING RECEPTACLES FOR ALL DWELLING <br />ROOMS, WITH THE EXCEPTION OF KITCHENS, BATHROOMS, <br />AND GARAGES, SHALL REQUIRE AFCI PROTECTION. <br />5. IT IS THE RESPONSIBILITY OF THE LICENSED <br />ELECTRICIAN TO INSURE THAT ALL ELECTRICAL WORK IS <br />IN FULL COMPLIANCE WITH 2O17 NFPA 70, FLORIDA <br />RESIDENTIAL CODE 2020, AND ALL APPLICABLE <br />LOCAL STANDARDS, CODES, AND ORDINANCES. <br />6. ALL RECEPTACLES SHALL BE TAMPER RESISTANT PER NEC <br />406.12. <br />7. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY. <br />8. LUMINIAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED <br />PER THE PROVISIONS OF 2017 NEC 410.16(A) & (B) <br />9. RECESSED LIGHTING TO BE AIR TIGHT AND IC RATED <br />10. A MIN OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED <br />FIXTURES SHALL BE HIGH -EFFICIENCY LAMPS <br />11. GFCI DEVICES SHALL BE READILY ACCESSIBLE <br />12. REFER TO ENERGY CALCULATIONS FOR ADDITIONAL <br />INFORMATION. <br />13. PROVIDE THE REQUIRED CLEARANCES AROUND <br />PANELS AND DISCONNECTS IN COMPLIANCE WITH <br />NEC 110.26. <br />14. THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN <br />A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE <br />GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE <br />m <br />w <br />_ c <br />Lu <br />� O O F- <br />> OE Q O <br />w::)o1 <br />clLu ) w <br />Q�w� <br />_ J <br />5 a. c <br />YQI-Z <br />�LL00u <br />Z Z Z H Z <br />J_ J Q � J <br />w IL 2 tr G- <br />_jWC)0Q <br />= Z L- u) <br />�I-Qz❑ <br />Q <br />n <br />Q <br />(� N <br />v c <br />n <br />Pt <br />Q <br />Z <br />Q <br />O <br />0 <br />0 <br />t� <br />V <br />O <br />0 a. <br />m <br />0C> <br />J <br />LL U <br />0 <br />(n <br />w <br />0� <br />".0 U <br />LL w <br />U) <br />j <br />w <br />L� <br />z <br />0 <br />a <br />A <br />O_ <br />r <br />L1C <br />U) <br />w <br />Uw <br />O� <br />E <br />o <br />�cs <br />Z <br />aaaaa <br />COMMUNITY: <br />LINKS @ CALUSA SPRINGS <br />PLAN # 6101 <br />RELEASED: 1/19/22 <br />SHEET <br />E• <br />