My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6990 Faben Ln (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6990 Faben Ln (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 11:48:13 AM
Creation date
2/28/2025 8:17:18 AM
Metadata
Fields
Template:
Building Plans
Street #
6990
Location
Faben Ln
Contractor
KHFO LLC
Building Plans - Permit #
3543
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V-011 <br />- <br />ROOF PLAN <br />SCALE: 1/4"=1'-0" <br />ATTIC VENTILATION <br />ATTIC AREA <br />TOTAL VENTING REQUIRED <br />2403 SQ. FT. <br />1 153 SQ. IN. <br />UPPER VENT 40% NET VENT MIN. <br />461 SQ. IN. <br />UPPER VENT 50% NET VENT MAX. <br />577 SQ. IN. <br />UPPER VENTS REQUIRED <br />48" TAMCO OFF -RIDGE VENT (138 SI NET FREE) <br />4 VENTS <br />NET FREE AREA UPPER ROOF VENTING <br />552 SQ. IN. <br />NET FREE AREA SOFFIT VENTING <br />601 SQ. IN. <br />LINEAR FT. SOFFIT REQ'D AT 6.57 SQ. IN. / LF. <br />92 LF. <br />NOTE: LOCATE RIDGE VENTS 2'-0" OFF ALL <br />HIPS RIDGES OR VALLEYS, MIN., TYP. <br />R806.2:THE MINIMUM NET FREE VENTILATING AREA SHALL <br />NOT BE LESS THAN 1/150 OF THE VENTED SPACE. <br />EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA <br />SHALL BE 1/300 OF THE VENTED SPACE PROVIDED NOT <br />LESS THAN 40 PERCENT AND NOT MORE THAN 50 <br />PERCENT OF THE REQUIRED VENTILATING AREA IS <br />PROVIDED BY VENTILATORS LOCATED IN THE UPPER <br />PORTION OF THE ATTIC OR RAFTER SPACE. UPPER <br />VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 <br />FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF <br />THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE <br />OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR <br />CORNICE VENTS. WHERE THE LOCATION OF WALL OR <br />ROOF FRAMING MEMBERS CONFLICTS WITH THE <br />INSTALLATION OF UPPER VENTILATORS, INSTALLATION <br />MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR <br />HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. <br />UNDERLAYMENT APPLICATIONS SHALL BE INSTALLED IN <br />ACCORDANCE WITH SECTION R905 <br />FOR ASPHALT SHINGLES REFERENCE TO SECTION R905.2 <br />FOR TILE ROOFING REFERENCE TO SECTION R905.3 <br />MAR 2 2 2022 <br />EAl <br />A OF <br />w <br />} 2 CC <br />Lu <br />OOF=- <br />> cc 0 <br />p F- <br />(lJUWW <br />Q=W_F- <br />= F- <br />°LfZZ�W <br />WQ�..Q�OJ <br />_ - <br />?(n00Q <br />�F-Q90 <br />N <br />tQi <br />j Qo <br />Zt <br />Hg <br />2 <br />O <br />u <br />0 <br />Im <br />o <br />a <br />LL <br />0 <br />o <br />O <br />w <br />M <br />al <br />z <br />0 <br />A <br />z <br />0 <br />E <br />a <br />o <br />U <br />0 <br />19 <br />�o <br />4Qa4a <br />o�z <br />I <br />I <br />I <br />COMMUNITY: <br />I <br />I <br />PLAN # 6101 <br />RELEASED: 1/19/22 <br />SHEET i <br />A3. I <br />r <br />O <br />z <br />w <br />0 <br />z_ <br />z <br />5 <br />w <br />co <br />W <br />17 <br />U) <br />O <br />z <br />0 <br />z <br />5 <br />CL <br />W <br />In <br />W <br />
The URL can be used to link to this page
Your browser does not support the video tag.