My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (115)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (115)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 11:05:51 AM
Creation date
2/28/2025 8:17:47 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Brasfield and Gorrie LLC
Building Plans - Permit #
17470
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
205
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 ■ 2 ■ 3 ■ 4 ■ 5 ■ 6 ■ 7 ■ 8 ■ c ■ 10 ■ i1 ■ 12 ■ 13 ■ 14 ■ 15 ■ 16 ■ 17 ■ 18 ■ 19 ■ 20 <br />R <br />000�� <br />X. 2 MAX. <br />2' MA -- -------------- <br />1' MIN. , y � z <br />TYP. <br />000000��f >� <br />LU <br />48' MAX. ' ' z <br />METAL STUDS BEHIND GYP. BD. <br />M f__ <br />METAL RUNNERS M t: <br />PACK WITH THERMAFIVER <br />0 CUTOUT MAXMULTIPLE CONDUIT / PIPE PENETRATIONS SAFING At MANUFACTURED U_ <br />. (r �� _ _ _ <br />6X6 DENSITY WITH NO VOIDS OR U, <br />GAPS <br />STUD <br />■ <7 C.M.U. OR CONCRETE - <br />PROPRIATORY SYSTEM OR <br />PARTIAL ELEVATION U.L. TESTED NONSHRINK <br />GROUT - FILL OPENING <br />COMPLETELY <br />MAIN WALL <br />SURFACE � u _ r ... <br />r----U_ <br />:W AS REQUIRED FOR CLOSURE <br />0 <br />PATCH : M <br />PROVIDE CELL CLOSURE OF 4 <br />R4 SCREW NON-COMBUSTIVLE MATERIAL <br />_- IN C.M.U. WALLS <br />_ RUNNER TRACK 'I 3/4" PARTIAL ELEVATION SECTION <br />CONCRETE MASONRY UNITS OR SOLID CONCRETE WALLS 5/16 8 1/21, <br />■NOTE <br />RUNNER TRACK INSTALL BLOCKING/FRAMING AT MTL, STUD <br />SECTION WALLS AS REQUIRED FOR INSTALLATION <br />L's <br />�UM PLASTER AN <br />aTHSON META STUDS METAL L15 FE/FV CABINET SECTION <br />TAPE AND FINISH <br />■ <br />SECTION NO SCALE <br />FLUSH PATCH -SMALLSAS REQUIRED FOR CLOSURE <br />1 OR 2 HOUR 2'-0' ACOUSTICAL SEALANT <br />K REFER TO RATED WALL ASSEMBLY TABLE FIRE OR <br />AT DETAIL Al PLASTER AND METAL LATH SMOKE WALL MIN. BACK AND SIDES OF <br />BOX AS NECESSARY <br />FOR SOUND RATING <br />TYP. SECT. , ,F—STUDS GYPSUM PLASTER, METAL LATH AND METAL STUD PARTITIONS <br />RUNNER CHANNELS, TYPICAL <br />GWB PATCH (BUTTER BACKSIDE SURFACE) <br />S i----------5 i <br />_ MIN. 2 'S' SCREWS PER SECTION, MIN. 3' <br />FROM OPENING AND EDGE OF PATCH <br />ANNULAR OPENING IN PARTITION AROUND <br />PIPE OR CONDUIT GREATER THAN 3' DIA. MAX. 16 SQ. IN. MAX. OPENING: <br />r--------- -� 100 SQ. IN./100 SQ. Ft. <br />z CUT GYPSUM BOARD TIGHT t0 PIPE <br />�S - is I TELEPHONE OR ACOUSTICAL SEALANT AROUND <br />ELECTRICAL BOXES BOX PENETRATION <br />' MI ' ' ' ADJACENT ELECTRICAL BOXES <br />i DO NOT MUD AND TAPE EDGES <br />HOLES OVER 3' DIA. <br />LAMINATE BACK PIECE <br />tYP. SEGt. CEILING t0 GYPSUM BOARD <br />� Z <br />GWB PATCH BUTTER BACKSIDE <br />G - SURFACE. DO NOT REMOVE JOINT <br />g COMPOUND DISPLACED At EDGES. = SEAL <br />TWO HOUR WALL ONE HOUR WALL <br />' s (EXAMPLE) (EXAMPLE) F F o <br />' ;Nz TYPE 'G' SCREWS MIN. 2 PER SECTION. _ <br />' LEAVE EXPOSED. <br />A <br />(V MIN. HORIZONTAL JOINT REQUIREMENTS ABOVE SUSPEND C DEEILINGS <br />ANNULAR OPENING IN PARTITION SHALLOW 5 SIDE BOX DETAIL-73 <br />w lea <br />S S AROUND PIPE OR CONDUIT 3' Via: A <br />NOTES: Ate, �°• (� °� <br />DIA. OR LESS. 1. JOINTS MAY BE OPPOSITE IF SAFEING IS USED IN CAVITY. F15 BOX DETAILS AT RATED WALLS�� <br />2. JOINTS IN FINISH LAYER TO RECEIVE TAPE AND JOINT COMPOUND <br />MIN <br />HOLES UP t0 3' DIA. HOLES UP TO 3' DIA. NO SCALE PAUL' .L.INACI KE AR0016073 <br />BLOWOUT PATCH GREATER THAN 2' FLORIDA HOSPITAL <br />ONLY 1 LAYER ON EACH SIDE OF WALL LESS THAN 6' <br />REQUIRED FOR 1 OR 2 HOUR WALLS. -� - . Ze h chills <br />-'- f ° r i <br />BLOWOUT PATCH IS NOT ACCEPTABLE ON • 1 p y <br />WALLS RATED AT 3 OR 4 HOURS. <br />FLOOR OR ROOF SLAB ASSEMBLY ED EXPANSION & ORTHO <br />NOTES: HIGHEST PRIORITY <br />I. BUTTER ENTIRE BACK SIDE OF PATCH WITH 1/4' NOM. GAP FILL WITH RENOVATION <br />JOINT COMPOUND, ACOUSt. SEALANT <br />2. LEAVE ALL SCREWS EXPOSED. CUT GYPSUM PANELS t0 FIT <br />DECK CONF IG. <br />RUNNERS - ATTACH WITH <br />D 4— L ANCHORS 2, 4, O.C. <br />TYPICAL PENETRATIONS At RATED WALL ASSEMBLY TABLE CEILING LOWEST PRIORITY Hunton <br />FIRE RATING PENETRATION UL DESIGN NO, <br />WALL PRIORITY LEGEND <br />STEEL DUCT CONTINUOUS STEEL STUDS A R C H I T E C T S <br />I- HOUR - 12 x 12 OR SMALLER W - L - 1001 <br />(16' / 24' D.C.) 2-HOUR SMOKE BARRIER PRIORITY 1 HIGHEST <br />AND - 24 x 12 OR SMALLER W - L - 1012 2-HOUR FIRE BARRIER <br />2- HOUR - 26 x 30 OR SMALLER W - L - 1014 :> PRIORITY 2 DATE SUBMISSION NO. <br />2-HOUR SHAFTWALL 04.15.16 CONSTRUCTION DOCUMENTS <br />PIPE PENETRATIONS RUNNERS - ATTACH WITH 1-HOUR SMOKE BARRIER PRIORITY 3 <br />- STEEL VENT PIPE (6' DIAM. OR SMALLER) W - L - 1019 ANCHORS 2'-0' O.C. <br />- INSULATED 4 NON -INSULATED METAL PIPE W - L - 8010 ACOUSTICAL SEALANT 1-HOUR FIRE BARRIER PRIORITY 4 <br />a <br />I -HOUR (2' DIAM. OR SMALLER) <br />AND OUR ' PVC PIPE (2' DIAM. OR SMALLER), W - L - 8004 z <br />p FIN. FLOOR NON -RATED WALL PRIORITY 5 LOWEST <br />B ELEC, CONDUIT (3' DIAM. OR SMALLER), <br />PVC INSULATED TELEPHONE 4 POWER CABLE NOTES: <br />1. SCHEDULE CONSTRUCTION OF WALLS ACCORDING TO PRIORITY. <br />■ BOTH SIDES OF PRIORITY 1 THRU 4 WALLS SHALL BE <br />1 - HOUR FIRE EXTINGUISHER CABINETS W - L - 1004 RATED PENETRATION DETAILS <br />2. SEALED AND STENCILLED At THE 80% CONSTRUCTION SURVEY. <br />A6 FIRE PENETRATION DETAILS A15 PARTITION PRIORITY PROJ. NO. H-15021.00 SHEET <br />DRAWN DMC <br />NO SCALE NO SCALE A051 <br />■ ■ ■ 4 ■ 4 ■ 6 ■ T ■ ■ ■ 10 ■ 11 ■ 12 ■ 1 ■ 14 ■ 15 ■ 1 ■ 1'f ■ 18 ■ 1 � ■ 28 <br />Copyright HuntonBrady Architects P.A. All Rights Reserved. 800 N. Magnolia Ave., Suite 600, Orlando, Florida 32803 (407) 839-0886 (407) 839-1709/Fax www.huntonbrady.com License AAC001744 <br />11 FII- T-T - <br />
The URL can be used to link to this page
Your browser does not support the video tag.