Laserfiche WebLink
'1 1_ V1 _ I I <br />DRIVE WAY / PARKING LOT <br />LIFE SAFETY LEGEND <br />EXIT SIGN <br />z <br />J <br />I <br />LLI <br />l� <br />CL <br />z <br />LL <br />Ir <br />_ <br />N <br />F- <br />z <br />W <br />n <br />Q <br />I <br />z <br />W <br />U <br />I <br />00 <br />0 <br />z. <br />0 <br />N <br />N <br />Ea_ <br />U N <br />01 <br />0 6 <br />cr? <br />cn o <br />C 1 N <br />U)rn <br />U N <br />w <br />U) <br />U_ <br />06 <br />U <br />U) <br />U_ <br />0 <br />v_ <br />LO <br />SEMI SEMI <br />PRIVATE PRIVATE <br />PATIENT PATIENT <br />1 ROOM ROOM <br />RN <br />"F" <br />M ATE PRIVATE TLT <br />SEMI F i1 ROOM ROOM �, 1j <br />PRIVATE, y_ <br />PATIENT <br />ROOM <br />rj} U1,11j aRM.:..... HO T .E T&RK TRM <br />46 <br />Cad 0 <br />1f `''"` <br />�T R Ll RM HIIINE TqT RM LT R <br />i SEMI e n U) <br />U PRIVATE <br />PATIENT a V <br />ROOM PRIVATE PRIVATE <br />_F_ PATIENT PATIENT <br />R ROOM ROOM L R <br />SEMI N-.: ,...�� <br />PRIVATE PRIVATE <br />PATIENT PATIENT <br />ROOM ROOM <br />- SMOKE COMPARTMENT 1E-1 <br />5,460 SF <br />SC 1A-2 <br />2,070 SF <br />nuAcc '3 <br />urvvr-rt <br />CONSTRUCTION <br />�,���+� SC 1B-1 <br />p <br />9,720 SF <br />PHASE 4 <br />PHASE 2 PHASE 5 <br />KEY NOTES <br />INTERIM LIFE SAFETY CALCULATIONS <br />1 <br />DINING/ACTIVITY/SOCIAL SPACE PROVIDED (PER FBC 450.3.5.1) <br />NOURISHMENT ROOM PROVIDED (PER FBC 450.3.4.1.6) <br />PHASE 1 UNDER CONSTRUCTION - ACTUAL SQ FT <br />102 BEDS AVAILABLE <br />ACTIVITY 0 35 SF/PERSON = 3,696 SQ FT <br />REQUIRED SQ FT <br />= 3,570 SQ FT <br />2 <br />4 <br />SOILED HOLDING & CLEAN HOLDING (PER FBC 450.3.4.1.2) <br />5 <br />NURSE STATION AND MEDICATION ROOM PROVIDED (PER FBC 3.4.1.5 & 3.4.1.1) <br />PROVIDE TEMPORARY EXIT SIGN <br />DINING (MIN. OF 20 = 2,280 SQ FT <br />SF/PERSON) <br />= 2,040 SQ FT <br />- <br />6 <br />-- <br />PHASE 2 UNDER CONSTRUCTION -101 BEDS AVAILABLE <br />7 <br />CONFIRM EXISTING 4 HOUR FIRE RATED WALLS ARE ALSO SMOKE TIGHT. IF NEEDED, <br />UPGRADE AS REQ'D TO MEET SMOKE COMPARTMENTS REQUIREMENTS <br />ACTIVITY @ 35 SF/PERSON = 3,737 SQ FT <br />= 3,535 SQ FT <br />9 <br />DINING ROOM (MIN. OF 20 = 2,466 SQ FT <br />SF/PERSON) <br />= 2,020 S FT <br />10 <br />11 <br />SMOKE COMPARTMENT 1A-1 SHALL BE MODI FED TO COMPLY WITH NPFA 2012 19.3.6.1 <br />(1) <br />SMOKE COMPARTMENT 1D-1 SHALL BE MODIFED TO COMPLY WITH NPFA 2012 19.3.6.1 <br />(1) <br />PHASE 3 UNDER CONSTRUCTION -101 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 3,561 SQ FT <br />DINING ROOM (MIN. OF = 2,305 SQ FT <br />20SF/PERSON) <br />= 3,535 SQ FT <br />= 2,020 SQ FT <br />PHASE 4 UNDER CONSTRUCTION -100 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 3,515 SQ FT <br />= 3,500 SQ FT <br />DINING ROOM (MIN. OF = 2,466 SQ FT <br />20SF/PERSON) <br />PHASE 5 UNDER CONSTRUCTION -101 BEDS AVAILABLE <br />= 2,000 SQ FT <br />ACTIVITY @ 35 SF/PERSON = 3,638 SQ FT <br />= 3,535 SQ FT <br />DINING ROOM (MIN. OF = 2,642 SQ FT <br />20SF/PERSON <br />= 2,020 SQ FT <br />PHASE 6 UNDER CONSTRUCTION -100 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 4,268 SQ FT <br />DINING ROOM (MIN. OF = 2,642 SQ FT <br />20SF/PERSON) <br />= 3,500 SQ FT <br />= 2,000 SQ FT <br />PHASE 7 UNDER CONSTRUCTION -113 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 4,053 SQ FT <br />= 3,955 SOFT <br />DINING ROOM (MIN. OF = 2,384 SQ FT <br />20SF/PERSON) <br />= 2,260 SQ FT <br />u) <br />N <br />U_ <br />cn <br />O <br />W. <br />INTERIM LIFE SAFETY PLAN - PHASE 3 1 <br />GENERAL NOTES <br />A GENERAL CONTRACTOR WILL ENSURE THAT ALL MEANS OF EGRESS ARE ALWAYS CLEAR <br />OF OBSTRUCTIONS. ANY DISRUPTION TO REGULAR MEANS OF EGRESS WILL BE <br />COORDINATED BETWEEN THE GENERAL CONTRACTOR AND THE OWNER. <br />B THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR POSTING TEMPORARY SIGNAGE <br />IN THE WORK AREA HIGHLIGHTING ANY CHANGES TO REGULAR LIFE SAFETY ROUTES AND <br />PROVIDING SAFE ALTERNATE MEANS OF EGRESS- COORDINATE WITH OWNER. <br />C THE GENERAL CONTRACTOR WILL HAVE A FULL TIME SUPERVISOR ON SITE DURING <br />CONSTRUCTION. THE GENERAL CONTRACTOR WILL ALSO PROVIDE A FIRE WATCH AT THE <br />AUTHORITY HAVING JURISDICTION'S REQUEST. <br />D ANY WORK THAT COULD DISRUPT NORMAL MEANS OF EGRESS WILL BE PERFORMED AT <br />NIGHT TIME HOURS WHEN THERE IS NO PATIENT TRAFFIC. <br />E ACCESS TO EMERGENCY TREATMENT AREAS WILL BE FREE AND UNOBSTRUCTED AT ALL <br />TIMES. ACCESS TO BUILDING ENTRANCES, FIRE DEPARTMENT CONNECTIONS, MEDICAL <br />GAS SYSTEM ACCESS POINTS, AND FIRE OR OTHER EMERGENCY EQUIPMENT ACCESS <br />ROADWAYS WILL ALSO BE FREE AND UNOBSTRUCTED AT ALL TIMES. <br />F FIRE ALARM DETECTION AND SUPPRESSION SYSTEMS WILL BE MAINTAINED IN GOOD <br />WORKING ORDER AT ALL TIMES. WHEN CONSTRUCTION REQUIRES THAT A FIRE ALARM <br />DETECTION OR SUPPRESSION SYSTEM BE DISABLED FOR ANY PERIOD OF TIME, A <br />TEMPORARY BUT EQUIVALENT SYSTEM OR PLAN WILL BE PROVIDED BY THE GENERAL <br />CONTRACTOR, INCLUDING, BUT NOT LIMITED TO A FIRE WATCH. <br />G TEMPORARY CONSTRUCTION PARTITIONS WILL BE CONSTRUCTED TO ASSURE THAT <br />SMOKE, DUST, AND INFECTIOUS DISEASES ARE NOT TRANSMITTED. THESE PARTITIONS <br />WILL BE CONSTRUCTED AS SHOWN ON SHEET D5.01. <br />H ALL EXIT SIGNAGE WILL REMAIN IN OPERATION AND VISIBLE DURING CONSTRUCTION. ANY <br />SIGNAGE AFFECTED BY NEW CONSTRUCTION OR TEMPORARY WORK OR NOT VISIBLE DUE <br />TO CONSTRUCTION WILL BE SUBSTITUTED BY THE GENERAL CONTRACTOR WITH A <br />TEMPORARY EQUIVALENT SIGNAGE TO ENSURE LIFE SAFETY. <br />THE OWNER WILL PROVIDE AND GENERAL CONTRACTOR WILL PERFORM ANY ADDITIONAL <br />INTERIM LIFE SAFETY PLANS AS REQUIRED. <br />J PROVIDE WALK OFF MATS AT ALL CONSTRUCTION ENTRANCES/EXITS AND AT ICRA <br />ENTRANCES. TYPICAL OF ALL PHASES OF CONSTRUCTION. <br />LJJ M,- L IU,- <br />El <br />Q <br />FVC <br />Lxx <br />HORN - STROBE - HORN/STROBE <br />SMOKE DETECTOR <br />FIRE EXTINGUSHER CABINET <br />FIRE VALVE CABINET <br />EXIT EGRESS CAPACITY: XX <br />CAPACITY IN INCHES <br />•������������• DEAD END CORRIDOR <br />COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO <br />SMOKE COMPARTMENT (SC) <br />TRAVEL DISTANCE TO EXIT <br />_ 1 HR RATED <br />_ WALL/PARTITION <br />1 HR RATED SMOKE BARRIER <br />2 HR RATED <br />WALL/PARTITION <br />2 HR RATED SMOKE BARRIER <br />3 HR RATED <br />WALL/PARTITION <br />4 HR RATED <br />WALL/PARTITION <br />4 HR RATED SMOKE BARRIER <br />- FIRE SMOKE <br />WALL/PARTITION <br />SCOPE OF WORK - <br />UNDER CONSTRUCTION <br />SCOPE OF WORK - <br />FUTURE WORK - NOT UNDER <br />CONSTRUCTION <br />SCOPE OF WORK - NOT UNDER <br />CONSTRUCTION <br />REQ'D SUPPORT SPACES PER <br />F7 <br />PHASE <br />1 " = 20'-0" <br />SMOKE COMPART. & FIRE SECTIONS LEGEND KEY PLAN (N.T.S.)- <br />FIRE SECTION 1A NOT IN SCOPE <br />AREA OF WORK <br />PH2 1--, PH5-_-J <br />FI l <br />PROJECT NORTH TRUE NORTH <br />�7 <br />StudIOL-T-1 <br />2211 E 7th Ave, Suite A, Tampa, Florida 33605 <br />P:239.357.4983 AA26002372 <br />Califomia I Florida <br />PENINSULA ENGINEERING, INC <br />MEP&FP <br />2016 ALDEN ROAD <br />ORLANDO, FL 32803 <br />P: 407.246.1688 <br />LBA INTERIORS <br />INTERIOR DESIGN <br />5650 DTC PARKWAY <br />SUITE 100 <br />ENGLEWOOD, CO 80111 <br />P: 303.773.0436 <br />REVISIONS: <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />OF Flo <br />Q ��O PCO <br />„o <br />J, AR97653 = <br />Off, '>> C> <br />RE D A� <br />U <br />J CT TITLE: <br />P YRHILLS HEALTH & REHAB <br />ER <br />FINISH UPGRADE -SKILLED <br />NURSING FACILITY <br />--- PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL 33540 <br />PROJECT NUMBER: <br />FLTSP16003 <br />l ISSUED DATE: <br />12/16/2016 <br />SHEET TITLE: <br />INTERIM LIFE SAFETY PLAN - <br />PHASE 3 <br />LS2ml3D <br />2016 Studio+ <br />