Laserfiche WebLink
OVA <br />a� <br />J <br />L.LI <br />I <br />z <br />LL <br />_ <br />N <br />I­__ <br />U)I- <br />Z <br />W <br />Q <br />J <br />I- <br />Z <br />w <br />0 <br />0 <br />CV <br />4 <br />Ea_ <br />I <br />oIt <br />0 O <br />c �:? <br />Q)(c) <br />L O <br />a� N <br />Tn <br />U cV <br />w <br />Tn <br />LL <br />06 <br />U <br />LMI-PRIVATE » SEMI-PRIVATE1 � <br />PATIENT <br />1 ROOM k ROOM <br />PRIVATE PRIVATE r <br />PATIENT PATIENT <br />1 4; ROOM ROOM --� <br />SEMI -PRIVATE <br />PATIENT `` d <br />ROOM <br />LL -..� , <br />4 �-�NOT OCCUPIED <br />OD <br />17 <br />{ U) ��.HOWE a <br />SEMIPRIVATE 1 c <br />PATIEM"I" PRIVATE PRIVATE <br />ROOM I PATIENT PATIENT <br />tlll � ROOM ROOM <br />Q+ <br />SEMI-PR,vATF SEMIPRIVATE <br />PATIENT PATIENT <br />r 1200M ROOM <br />SMOKE COMPARTMENT 1E-1 <br />5,460 SF <br />RESIDENT <br />STORAGE <br />- DRIVE WAY / PARKING LOT <br />Ak <br />SC 1A-2 <br />Yowl-is <br />9,720 SF <br />PHASE 6 <br />LT -� 45 TLTI $EMI <br />- I uRM l, <br />PLL ATIENT Room <br />._..._. - #,AdVf1EN a <br />I hE <br />ROOM <br />45 LL LAUNDRO SOILED <br />SEMI -PRIVATE cV LINEN STOR. n WED MECH <br />PATIENT Q O SORTIN �RIgATE \l ROOM <br />ROOM f` FE • MECH. PATENT FE <br />® U O ,ROOM <br />AM �1 <br />_ N , <br />FE* 61iE � O to 04 i <br />OLDIN TLT _ <br />'� CLEAN MECH FOLDING ® USEKEEPt G RRI TE " <br />D SUPPLY ROOM ��{{qq N RSES <br />fIAT1ENT <br />r 45,, I 45 ROOM s TION r vs. <br />PHASE 3 <br />2,070 SF <br />r <br />TO MECH. <br />i <br />45 <br />ELEC. <br />0 <br />SEMI -PRIVATE <br />-- - <br />PATIENT �- <br />- � ® SMOKE COMPARTMENT 18: 9,720 SF <br />t• ROOM I CDD] ___, QO �o SMOKE COMPARTMENT to-2 O ® ® O O ®�D <br />_Lf59Yt'LT.1a. CY ( �L1� <br />SEMI-PRIVATL aM TLT <br />SEMI•PRIVATI n <br />PATIENT OD PATIENT LA <br />MIROOM ROOM_j®TE PATIENT ^� <br />STORAGE <br />I L) ST I PATIENT ROOM <br />I�I ,.,Poa� .. LOUNGE -.. - <br />h W SEMI PRIVATE <br />SEMI-PRIYATE f <br />PATIENT F PATIENT O 1 Et�l <br />D <br />ROOM o Room PRIVATE (D} PRIVATE <br />U FE ® PHASE 7 I ATIENT TLT PATIPNT f I <br />U) rH P R TILT,RM d <br />Iwill <br />Y <br />SEMI-PRIVAT( O SEMI -PRIMATE i- FREEZER COOLER LLI STORAGE k �iT Ij I I <br />PATIENT PATIENT ; SSEI�I EA ! <br />. ROOM 1 N Poor ....d I _,I PRIVATE PRIVATE <br />PATIENT PATIENT <br />09 ROOM 09 <br />SEMI -PRIVATE SEMI -PRIVATE SEMI SEMI <br />PRIVATE <br />_"IE NT <br />(j O <br />IY NURSES <br />STATION <br />)�?IVATE s L <br />ENT --- MED <br />O )M - .. ROOM Di <br />it C <br />O <br />F�M O AD ADL <br />OFFICE r I TL KITCHEN.' OFFICE <br />t! <br />FF- CHARTING <br />COO) <br />PHYSICAL THERAPY <br />I <br />PHASE 4 <br />PAT] ENT PATIENT I <br />NILT <br />MWOM <br />10Milk PRIVATE RIME PRIVATE <br />1 PATIENT PATIENT PATIENT <br />PATIENT ROO <br />FMI 'Yi <br />IN <br />TLT RN TIT RM <br />•� 0 • r----- <br />\ I <br />BEAL) 1) <br />a FE <br />�I aROOM o IT <br />=RM <br />. <br />�,. <br />�, �� R • a a .. • I <br />j <br />Lj <br />I I <br />_ � 1 <br />\I�RIVATE <br />SEMI PRIVATE <br />PATIENT PATIENT <br />NIPATIENT <br />I 5_ <br />SEMI -PRIVATE D <br />PATIENT S EMI=PRI VAT <br />L PATIENT p <br />O ROOM 86'•3^ ROOM <br />LPL � I:'.:.i I <br />PRIV TE 6 I_ _ 1 P IVATE <br />U (PATIENT PATIENT ' <br />ROOM OFE ROOM <br />SOILED' 'CLEAN <br />LDIN OLDIN <br />PRIVATE PRIVATE <br />PATIENT PATIENT 3 <br />ROOM a �D� 00M <br />SEMI-PFIIVATE SEMI -PRIVATE <br />; PATIENT <br />PATIENT O - i ROOM( <br />R. <br />SEMI -PRIVATE SEMI -PRIVATE <br />PATIENT <br />45 r PATIENT <br />ROOM._ ROOM .. ...P:. <br />7- z=, <br />PHASE 2 <br />OFFICE rFFI0E <br />KEY NOTES <br />INTERIM LIFE SAFETY CALCULATIONS <br />01 <br />DINING/ACTIVITY/SOCIAL SPACE PROVIDED (PER FBC 450.3.5.1) <br />PHASE 1 UNDER CONSTRUCTION - ACTUAL SQ FT <br />REQUIRED SQ FT <br />02 <br />NOURISHMENT ROOM PROVIDED (PER FBC 450.3.4.1.6) <br />102 BEDS AVAILABLE <br />04 <br />SOILED HOLDING & CLEAN HOLDING (PER FBC 450.3.4.1.2) <br />ACTIVITY 0, 35 SF/PERSON = 3,696 SO FT <br />= 3,570 SO FT <br />05 <br />NURSE STATION AND MEDICATION ROOM PROVIDED (PER FBC 3.4.1.5 & 3.4.1.1) <br />DINING (MIN. OF 20 = 2,280 SO FT <br />= 2,040 SO FT <br />06 <br />PROVIDE TEMPORARY EXIT SIGN <br />SF/PERSON) <br />08 <br />SERVICES PROVIDED ON AS NEEDED BASIS IN RESIDENT ROOMS <br />PHASE 2 UNDER CONSTRUCTION -101 BEDS AVAILABLE <br />- <br />09 <br />CONFIRM EXISTING 4 HOUR FIRE RATED WALLS ARE ALSO SMOKE TIGHT. IF NEEDED, <br />ACTIVITY @ 35 SF/PERSON = 3,737 SO FT <br />= 3,535 SO FT <br />UPGRADE AS REQ'D TO MEET SMOKE COMPARTMENTS REQUIREMENTS <br />DINING ROOM (MIN. OF 20 = 2,466 SO FT <br />= 2,020 SO FT <br />10 <br />SMOKE COMPARTMENT 1A-1 SHALL BE MODI FED TO COMPLY WITH NPFA 2012 19.3.6.1 <br />SF/PERSON) <br />(1) <br />PHASE 3 UNDER CONSTRUCTION -101 BEDS AVAILABLE <br />11 <br />SMOKE COMPARTMENT 1 D-1 SHALL BE MODIFIED TO COMPLY WITH NPFA 2012 19.3.6.1 <br />ACTIVITY @ 35 SF/PERSON = 3,561 SO FT <br />= 3,535 SO FT <br />(1) <br />DINING ROOM (MIN. OF = 2,305 SO FT <br />= 2,020 SO FT <br />12 <br />ITEMPORARY PUBLIC TOILET ROOM <br />20SF/PERSON) <br />13 <br />ITEMPORARY CONFERENCE ROOM USED AS AN AS NEEDED BASIS ONLY <br />PHASE 4 UNDER CONSTRUCTION -100 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 3,515 SO FT <br />-= <br />= 3,500 SO FT <br />DINING ROOM (MIN. OF 2,466 SO FT <br />= 2,000 SO FT <br />20SF/PERSON) <br />PHASE 5 UNDER CONSTRUCTION -101 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 3,638 SO FT <br />= 3,535 SO FT <br />DINING ROOM (MIN. OF = 2,642 SO FT <br />= 2,020 SO FT <br />20SF/PERSON <br />PHASE 6 UNDER CONSTRUCTION -100 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 4,268 SO FT <br />= 3,500 SO FT <br />DINING ROOM (MIN. OF = 2,642 SO FT <br />= 2,000 SO FT <br />20SF/PERSON) <br />PHASE 7 UNDER CONSTRUCTION -113 BEDS AVAILABLE <br />ACTIVITY @ 35 SF/PERSON = 4,053 SO FT <br />= 3,955 SQFT <br />DINING ROOM (MIN. OF = 2,384 SO FT <br />= 2,260 SO FT <br />20SF/PERSON) <br />IT <br />©a <br />_CONFERENCE ROOOj�MM <br />O <br />Q <br />' V <br />67 <br />FIRE ALARM <br />CONTROL <br />PANEL <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />SC 1A-1 <br />21,440 SF <br />I I <br />I I <br />I I <br />❑ ❑ <br />L-.. ______-_J <br />GENERAL NOTES <br />RECEPTION (r <br />- <br />- Ip <br />06 <br />II STOR <br />08 �` <br />AFF G <br />I I I <br />(4) <br />56y1PRIVATE <br />u <br />PATIENT R QM..-•_. <br />C <br />II <br />LJI <br />I P7, <br />SEMI PRIVAT <br />SEMI PRIVATE <br />PATIENT ROOK <br />li <br />d ROOM . ATIENT ' PATIENT ;c T <br />TLT R ROOM' RIX" - TLT Room <br />05 - , SEMI,_.. __.-.11 _._ SEMI - <br />I'RIVAFt._...-,-.'' _ IiRIVATi .-I; <br />PATIENT PATIENT <br />ROOM L 13'i F ROOM <br />ELEC 'I <br />SEMIP"E <br />PATIENT ROOM <br />r---� <br />LT - T <br />SEMI PRIVAT <br />PATIPIN <br />=I <br />I FE Y- PATIEVOT <br />CORRIDOR �- <br />- 7 - SEMI PRIVATE <br />Co% I <br />F <br />LT <br />R <br />- <br />TLT_( <br />TI R <br />SEMI PRIVATE <br />SEMI PRIVATE <br />PATIENT ROOM <br />11 <br />ROOM <br />_PATIENT <br />PHASE 5-UNDER <br />CONSTRUCTION <br />Al <br />INTERIM LIFE SAFETY PLAN - PHASE 5 1 <br />A GENERAL CONTRACTOR WILL ENSURE THAT ALL MEANS OF EGRESS ARF ALWAYS CLEAR <br />OF OBSTRUCTIONS. ANY DISRUPTION TO REGULAR MEANS OF EGRESS WILL BF <br />COORDINATED BETWEEN THE GENERAL CONTRACTOR AND THE OWNER. <br />B THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR POSTING TEMPORARY SIGNAGE <br />IN THE WORK AREA HIGHLIGHTING ANY CHANGES TO REGULAR LIFE SAFETY ROUTES AND <br />PROVIDING SAFE ALTERNATE MEANS OF EGRESS- COORDINATE WITH OWNER. <br />C THE GENERAL CONTRACTOR WILL HAVE A FULL TIME SUPERVISOR ON SITE DURING <br />CONSTRUCTION. THE GENERAL CONTRACTOR WILL ALSO PROVIDE A FIRE WATCH AT THE <br />AUTHORITY HAVING JURISDICTION'S REQUEST. <br />D ANY WORK THAT COULD DISRUPT NORMAL MEANS OF EGRESS WILL BE PERFORMED AT <br />NIGHT TIME HOURS WHEN THERE IS NO PATIENT TRAFFIC. <br />E ACCESS TO EMERGENCY TREATMENT AREAS WILL BE FREE AND UNOBSTRUCTED AT ALL <br />TIMES. ACCESS TO BUILDING ENTRANCES, FIRE DEPARTMENT CONNECTIONS, MEDICAL <br />GAS SYSTEM ACCESS POINTS, AND FIRE OR OTHER EMERGENCY EQUIPMENT ACCESS <br />ROADWAYS WILL ALSO BE FREE AND UNOBSTRUCTED AT ALL TIMES. <br />F FIRE ALARM DETECTION AND SUPPRESSION SYSTEMS WILL BE MAINTAINED IN GOOD <br />WORKING ORDER AT ALL TIMES. WHEN CONSTRUCTION REQUIRES THAT A FIRE ALARM <br />DETECTION OR SUPPRESSION SYSTEM BE DISABLED FOR ANY PERIOD OF TIME, A <br />TEMPORARY BUT EQUIVALENT SYSTEM OR PLAN WILL BE PROVIDED BY THE GENERAL <br />CONTRACTOR, INCLUDING, BUT NOT LIMITED TO A FIRE WATCH. <br />G TEMPORARY CONSTRUCTION PARTITIONS WILL BE CONSTRUCTED TO ASSURE THAT <br />SMOKE, DUST, AND INFECTIOUS DISEASES ARE NOT TRANSMITTED. THESF PARTITIONS <br />WILL BE CONSTRUCTED AS SHOWN ON SHEET D5.01. <br />H ALL EXIT SIGNAGE WILL REMAIN IN OPERATION AND VISIBLE DURING CONSTRUCTION. ANY <br />SIGNAGE AFFECTED BY NEW CONSTRUCTION OR TEMPORARY WORK OR NOT VISIBLE DUE <br />TO CONSTRUCTION WILL BE SUBSTITUTED BY THE GENERAL CONTRACTOR WITH A <br />TEMPORARY EQUIVALENT SIGNAGE TO FNSURE LIFE SAFETY. <br />I THE OWNER WILL PROVIDE AND GENERAL CONTRACTOR WILL PERFORM ANY ADDITIONAL <br />INTERIM LIFE SAFETY PLANS AS REQUIRED. <br />J PROVIDE WALK OFF MATS AT ALL CONSTRUCTION ENTRANCES/EXITS AND AT ICRA <br />ENTRANCES. TYPICAL OF ALL PHASES OF CONSTRUCTION. <br />LIFE SAFETY LEGEND <br />EXIT SIGN <br />LA ED,_ FN <br />HORN STROBE -HORN/STROBE <br />1E <br />PULL STATION <br />SMOKE DETECTOR <br />FIRE EXTINGUSHER CABINET <br />-FVIC <br />FIRE VALVE CABINET <br />EXIT EGRESS CAPACITY: XX <br />xx <br />CAPACITY IN INCHES <br />DEAD END CORRIDOR <br />COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO <br />SMOKE COMPARTMENT (SC) <br />TRAVEL DISTANCE TO EXIT <br />1 HR RATED <br />WALUPARTITION <br />1 HR RATED SMOKE BARRIER <br />*6 <br />2 HR RATED <br />WALUPARTITION <br />-----.-- - <br />2 HR RATED SMOKE BARRIER <br />3 HR RATED <br />WALUPARTITION <br />4 HR RATED <br />WALUPARTITION <br />_ _yr <br />4 HR RATED SMOKE BARRIER <br />-- <br />FIRE SMOKE <br />WALUPARTITION <br />SCOPE OF WORK - <br />UNDER CONSTRUCTION <br />SCOPE OF WORK - <br />FUTURE WORK - NOT UNDER <br />- <br />CONSTRUCTION <br />SCOPF OF WORK - NOT UNDER <br />CONSTRUCTION <br />------------- <br />REQ'D SUPPORT SPACES PER <br />1 <br />PHASE <br />1 " = 20'-0" <br />SMOKE COMPART. & FIRE SECTIONS LEGEND KEY PLAN (N.T.S.)- <br />FIRE SECTION 1A F7771 <br />NOT IN SCOPE <br />AREA OF WORK <br />PROJECT NORTH <br />TRUE NORTH <br />studio <br />2211 E 7th Ave, Suite A, Tampa, Florida 33605 <br />P:239.357.4983 AA26002372 <br />Califomia I Florida <br />PENINSULA ENGINEERING, INC <br />MEP&FP <br />2016 ALDEN ROAD <br />ORLANDO, FL 32803 <br />P: 407.246.1688 <br />LBA INTERIORS <br />INTERIOR DESIGN <br />5650 DTC PARKWAY <br />SUITE 100 <br />ENGLEWOOD, CO 80111 <br />P: 303.773.0436 <br />REVISIONS: <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 <br />F F057 <br />�Q <br />= v_ <br />• Q it to <br />J, AR97653 = <br />O/, .�'>> c, <br />RED AR <br />P O & TITLE: <br />ZE HJl RHILLS HEALTH & REHAB <br />CENTER <br />FINISH UPGRADE - SKILLED <br />NURSING FACILITY <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL 33540 <br />PROJECT NUMBER: <br />FLTSP16003 <br />ISSUED DATE: <br />12/16/2016 <br />SHEET TITLE: <br />INTERIM LIFE SAFETY PLAN - <br />PHASE 5 <br />LS2m15Cc� 2016 Studio+ <br />