Laserfiche WebLink
—' ! ! ! L 1 1 11L1[►' ! �� �Il� F�I11'�II I - -,r - „ I' I_ I <br />N <br />w <br />C7 <br />a. <br />2 <br />Z <br />LL <br />w <br />2 <br />N <br />U) <br />F— <br />Z <br />w <br />QI <br />J <br />Z <br />w <br />U <br />00 <br />O <br />co <br />0 <br />C <br />E <br />O co <br />066 <br />C <br />N � <br />i� <br />N <br />U N <br />r- <br />LEGEND <br />A <br />GRID # <br />00 <br />PARTITION CALLOUT <br />Oo <br />KEYNOTE # <br />A101 <br />DR # CALLOUT <br />OWIN <br /># <br />CALLOUT <br />CLG HT AFF <br />FURNITURE / <br />EQUIPMENT TAG <br />X <br />DOOR ELECTRICAL DEVICE <br />— - <br />BLDG/PAVING ELEV <br />FEC FEC <br />Q�C <br />FIRE EXTINGUISHER CABINET <br />FE FE <br />&—'—I <br />FIRE EXTINGUISHER <br />Fvc <br />FIRE VALVE EXTINGUISHER <br />FIRE PULL <br />w <br />NORTH ARROW <br />LOCATION # <br />1 SIM / \ <br />1 <br />101 <br />SHEET # � � <br />DET CALLOUT <br />LOCATION # SIM <br />1 <br />101 <br />SHEET # <br />BLDG/WALUDTL SECT CUT <br />Al <br />LOCATION # - 0 A4Ao.00 AZ <br />SHEET # <br />A3 <br />INT ELEV CALLOUT <br />•������������• <br />DEAD END CORRIDOR <br />COMMON PATH OF TRAVEL <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TRAVEL DISTANCE TO EXIT <br />DEMOLISHED PARTITION <br />EXISTING PARTITION <br />NEW PARTITION <br />1 HOUR CONSTRUCTION BARRIER - <br />REFER TO PARTITION TYPES <br />- r X X X X x <br />FRP TEMP. BARRIER. <br />_ <br />1 HR RATED <br />WALUPARTITION <br />2 HR RATED <br />_ <br />WALUPARTITION <br />_ <br />3 HR RATED <br />----'�' - -� <br />WALUPARTITION <br />4 HR RATED <br />WALUPARTITION <br />SMOKE TIGHT <br />WALUPARTITION <br />1 HR RATED FIRE/SMOKE <br />-- <br />WALUPARTITION <br />2 HR RATED FIRE/SMOKE <br />— — <br />WALUPARTITION <br />AREA NOT IN CONTRACT <br />LEGEND <br />CEILING GRID <br />LAA O <br />LIGHT FIXTURES PER ELEC <br />®� <br />DIFFUSERS PER MECH <br />0 <br />SPRINKLER <br />X <br />EXIT SIGN <br />OWALL <br />FINISH <br />WALL BASE FINISH <br />FLOOR FINISH <br />TYPICAL DEVICE MOUNTING DIAGRAM <br />6" UO <br />w <br />O <br />rY C-0 <br />0 .l, <br />T <br />2 <br />0 �I <br />M w <br />O <br />0 <br />0 <br />cV <br />io <br />a <br />EDGE OF DOOR OR WALL <br />FIRE STROBE <br />I <br />THERMOSTAT <br />WALL PROTECTION, <br />- - (WHERE OCCURS) <br />TELEPHONE OR SECOND <br />ROW OF SWITCHES. <br />PROXIMITY & KEYPAD (CORR. SIDE) <br />SECURITY ALARM KEYPAD (RM SIDE) <br />GANG OF DIMMER SWITCHES <br />LIGHT SWITCH, DOOR RELEASE <br />BUTTON <br />WALL PROTECTION, <br />(WHERE OCCURS) <br />ELEC/DATA OUTLETS <br />DEVICE MOUNTING HIGHT <br />DIAGRAM AT EDGE CONDITIONS. <br />w <br />O <br />co <br />0 <br />O <br />- <br />0 <br />0 <br />m <br />O <br />> <br />J <br />m <br />fQ _ <br />o� <br />0 <br />VV <br />ci <br />EQ C� EQ [-*— COLUMN <br />FIRE STROBE <br />THERMOSTAT <br />WALL PROTECTION, <br />- - - (WHERE OCCURS) <br />_ TELEPHONE OR SECOND <br />ROW OF SWITCHES. <br />LIGHT SWITCH, DOOR <br />RELEASE BUTTON <br />WALL PROTECTION, <br />(WHERE OCCURS) <br />I I ELEC/DATA OUTLETS <br />DEVICE MOUNTING HIGHT DIAGRAM <br />AT COLUMN CONDITIONS. <br />NOTE: PROVIDE 6" MIN DIMENSION BETWEEN WALL MOUNTED DEVICES WHEN <br />LOCATED BACK TO BACK. PROVIDE 2" BETWEEN WALL MOUNTED DEVICES WHEN <br />LOCATED ADJACENT TO EACHOTHER AND AT THE SAME MOUNTING HEIGHT. <br />CONTRACTOR TO COORDINATE LOCATION OF STUDS IN PARTITION TO ACHIEVE <br />INTENT. PROVIDE ADDITIONAL STUDS/BRACING AS NEEDED. PROVIDE <br />SOUNDLINERS AT DEVICE BACK BOXES WHERE DEVICES ARE LOCATED IN <br />PARTITIONS WITH INSULATION. <br />GENERAL NOTES - PROJECT <br />A <br />ALL DOCUMENTS AND DRAWINGS INCLUDED HEREWITH ARE INTENDED TO BE IN CONFORMANCE WITH ALL APPLICABLE CODES AND BUILDING REGULATIONS HAVING <br />JURISDICTION OVER THIS TYPE OF FACILITY AND OCCUPANCY. IF A CONFLICT BETWEEN SUCH REQUIREMENTS OCCUR, THE MOST STRINGENT WILL GOVERN. <br />B <br />GENERAL CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY AND DOCUMENT ALL EXISTING FIELD CONDITIONS. ANY DEVIATIONS FROM THE EXISTING CONDITION DRAWINGS WILL <br />BE ADDRESSED IMMEDIATELY WITH THE ARCHITECT. <br />C <br />PRIOR TO COMMENCING ANY WORK THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATION OF ALL UTILITY POINTS OF CONNECTION AND INCLUDE ALL <br />ASSOCIATED WORK SUCH AS REPAIR / REPLACEMENT OF FINISHES WHERE NECCESSARY. <br />D <br />ALL BUILDING SYSTEM SERVICES (IE: WATER, SANITARY, FIRE ALARM, ELECTRIC, ETC...) WILL REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. ALL NECESSARY <br />INTERRUPTIONS FOR CONNECTION OF NEW WORK WILL BE PERFORMED AFTER NORMAL BUSINESS HOURS OR AS AGREED TO BY BUILDING OWNER. ANY REQUIRED <br />INTERRUPTIONS OF SERVICE WILL BE SCHEDULED AND APPROVED BY THE BUILDING OWNER 72 HOURS IN ADVANCE. ALL COST IMPACTS FOR AFTER HOURS WORK WILL BE <br />ANTICIPATED AND INCLUDED IN BID PROPOSAL. <br />E <br />CONTRACTOR WILL USE ONLY THOSE ENTRANCES AND PARKING FACILITIES ASSIGNED BY THE BUILDING OWNER FOR SITE ACCESS. ALL MATERIAL DELIVERIES WILL BE <br />SCHEDULED TO MINIMIZE DISRUPTIONS TO THE BUILDING OCCUPANTS. <br />F <br />GENERAL CONTRACTOR WILL SCHEDULE ALL WORK TO AVOID INTERRUPTIONS TO ADJACENT AREAS. ALL DISRUPTIVE WORK WILL BE SCHEDULED AND PERFORMED BEFORE OR <br />AFTER NORMAL BUSINESS HOUR. WORK STOPPAGE DUE TO VIBRATIONS, OR THAT DISTURB THE OCCUPANTS OF THE FACILITY WILL NOT BE GROUNDS FOR ADDITIONAL CHARGES <br />OR CHANGE ORDERS. <br />G <br />ALL EXISTING MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEMS NEEDED TO MAINTAIN CONTINUOUS OPERATIONS OF THE FACILITY, WILL BE CAPPED OFF <br />OR REROUTED AS NECESSARY. <br />H <br />IF SCOPE OF WORK REQUIRES THE REMOVAL OF FIXTURES OR DEVICES, ALL ASSOCIATED WIRE, BOXES, FRAMING AND PIPING NECESSARY TO ALLOW THE COMPLETE <br />INSTALLATION OF NEW FINISHES WILL BE REMOVED ALSO. <br />I <br />ALL SMOKE AND FIRE RATED WALLS WILL BE LABELED ABOVE THE CEILING FINISH WITH RED, PAINTED STENCILED LETTERING IDENTIFYING THE WALL RATING AND STATING <br />"PROTECT ALL PENETRATIONS." STENCILED LABELING WILL OCCUR ON BOTH SIDES OF EACH SMOKE AND FIRE RATED WALL AT NOT MORE THAN 20 FEET ON CENTER AND ALL <br />WALL TERMINATIONS OR CHANGES IN DIRECTION WILL BE DESIGNATED WITH A VERTICAL LINE. <br />J <br />SHOP DRAWINGS AND / OR SUBMITTALS FOR PRODUCTS, MATERIALS, ASSEMBLIES, AND SYSTEMS SPECIFIED IN THE CONTRACT DOCUMENTS WILL BE SUBMITTED BY THE <br />GENERAL CONTRACTOR TO THE ARCHITECT PRIOR TO FABRICATION IN ORDER TO VERIFY GENERAL CONFORMANCE WITH THE CONTRACT DOCUMENTS. SHOP DRAWINGS AND <br />SUBMITTALS MUST BEAR A REVIEW STAMP FROM THE GENERAL CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT. SHOP DRAWING REVIEW AND APPROVAL WILL <br />NOT RELIEVE ANY PARTY FROM MAINTAINING COMPLIANCE WITH THE CONTRACT DOCUMENTS. <br />K <br />DETAILS MARKED AS'TYP' OR TYPICAL' WILL APPLY IN ALL CASES UNLESS OTHERWISE NOTED. <br />L <br />ALL DIMENSIONS ARE TAKEN FROM GRID LINES OR FINISHED FACE OF WALL / PARTITION UNLESS OTHERWISE NOTED. <br />M JALL <br />WALLS INDICATED PER FGI 2010 TABLE 1.2-3 OR AS INDICATED IN DRAWINGS TO REQUIRE STC RATING SHALL BE PROVIDED PER USG. DESIGNSTUDIO.COM DESIGN SELECTOR. <br />ABBREVIATIONS <br />SYMBOL/ <br />ACCRONYM <br />DESCRIPTION <br />VIF <br />VERIFY IN FIELD <br /># <br />POUND OR NUMBER <br />% <br />PERCENT <br />+/- <br />PLUS/MINUS <br />- <br />NONE OR NOT APPLICABLE <br />AT <br />0 <br />DIAMETER OR ROUND <br />L <br />ANGLE <br />AB <br />ANCHOR BOLT <br />ABS <br />ABSOLUTE <br />AC <br />ASPHALTIC CONCRETE <br />ACC <br />ACCESSIBLE WORK STATION <br />ACOUS <br />ACOUSTICAL <br />ADJ <br />ADJACENT <br />AFF <br />ABOVE FINISHED FLOOR <br />AL/ALUM <br />ALUMINUM <br />ANSI <br />AMERICAN NATIONAL STANDARDS <br />INSTITUTE <br />ARCH <br />ARCHITECTURAL <br />BD <br />BOARD <br />BLDG <br />BUILDING <br />BLK <br />BLOCK <br />BLKG <br />BLOCKING <br />BTWN <br />BETWEEN <br />C <br />CHANNEL <br />CER <br />CERAMIC <br />CF <br />CUBIC FEET <br />CFCI <br />CONTRACTOR FURNISHED, <br />CONSTRACTOR INSTALLED <br />CFOI <br />CONTRACTOR FURNISHED, OWNER <br />INSTALLED <br />CJ <br />CONTROL JOINT <br />CL <br />CENTERLINE <br />CLG <br />CEILING <br />CLR <br />CLEAR <br />CMU <br />CONTRETE MASONRY UNIT <br />CONC <br />CONTRETE <br />CONSTR <br />CONSTRUCTION <br />CONT <br />CONTINUOUS <br />CORR <br />CORRIDOR <br />CT <br />CLEAR TEMPERED <br />CTC <br />CENTER TO CENTER <br />CTSK <br />COUNTERSUNK <br />DBL <br />DOUBLE <br />DEC <br />DEAD END CORRIDOR <br />DEL <br />DELETE <br />DET <br />DETAIL <br />DF <br />DRINKING FOUNTAIN <br />DIA <br />DIAMETER <br />DIM <br />DIMENSION <br />DL <br />DOOR LOUVER <br />DN <br />DOWN <br />DR <br />DOOR <br />DS <br />DOWNSPOUT <br />DWG <br />DRAWING <br />EA <br />EACH <br />EJ <br />EXPANSION JOINT <br />ELEC <br />ELECTRICAL <br />ELEV <br />ELEVATION <br />EMT <br />ELECTRICAL METAL TUBING <br />ENCL <br />ENCLOSURE <br />ENGR <br />ENGINEER <br />EOS <br />EDGE OF SLAB <br />EQ <br />EQUAL <br />EQPT <br />EQUIPMENT <br />EW <br />EACH WAY <br />EX <br />EXISTING <br />EXP <br />EXPANSION <br />EXT <br />EXTERIOR <br />FA <br />FIRE ALARM <br />FD <br />FLOOR DRAIN <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />FDN <br />FOUNDATION <br />FE <br />FIRE EXTINGUISHER <br />FEC <br />FIRE EXTINGUISHER W/ CABINET <br />FF <br />FINISHED FLOOR <br />FG <br />FINISHED GRADE <br />FH <br />FIRE HYDRANT <br />FHC <br />FIRE HOSE W/ CABINET <br />FL <br />FLOOR <br />FO <br />FACE OF <br />FOC <br />FACE OF CONCRETE <br />FOF <br />FACE OF FINISH <br />FOM <br />FACE OF MASONRY <br />FOS <br />FACE OF STUD <br />FRB <br />FIRE RETARDANT BARRIER <br />FS <br />FINISHED SURFACE <br />FT <br />FOOT OR FEET <br />ABBREVIATIONS <br />SYMBOL/ <br />ACCRONYM <br />DESCRIPTION <br />FTG <br />FOOTING <br />GA <br />GAUGE <br />GALV <br />GALVENIZED <br />GB <br />GYPSUM BOARD <br />GFRC <br />GLASS FIBER REINFORCED CONCRETE <br />GYP <br />GYPSUM <br />HB <br />HOSE BIB <br />HDWE <br />HARDWARE <br />HM <br />HOLLOW METAL <br />HOR <br />HORIZONTAL <br />HR <br />HOUR <br />HVAC <br />HEATING VENTILATION AIR CONDITIONING <br />ID <br />INSIDE DIAMETER <br />IG <br />FROSTED FILM OVER CLEAR INSULATED <br />TEMPERED GLAZING <br />IN <br />INCH OR INCHES <br />INT <br />INTERIOR <br />INV <br />INVERT <br />JAN <br />JANITOR CLOSET <br />JBOX <br />JUNCTION BOX <br />LAV <br />LAVATORY <br />LB(S) <br />POUND(S) <br />MAX <br />MAXIMUM <br />MB <br />MACHINE BOLT <br />MDF <br />MEDIUM DENSITY FIBERBOARD <br />MFR <br />MANUFACTURER <br />MH <br />MANHOLE <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MTL <br />METAL <br />NIC <br />NOT IN CONTRACT <br />NO <br />NUMBER <br />NR <br />NOT RATED <br />NTS <br />NOT TO SCALE <br />0/ <br />OVER <br />OA <br />OVERALL <br />OC <br />ON CENTER <br />OD <br />OUSIDE DIAMETER <br />OFCI <br />OWNER FURNISHED, CONTRACTOR <br />INSTALLED <br />OFOI <br />OWNER FURNISHED, OWNER INSTALLED <br />OH <br />OPPOSITE HAND <br />OTO <br />OUT TO OUT <br />PA <br />PUBLIC ACCESS <br />PE <br />PAD ELEVATION <br />PERP <br />PERPENDICULAR <br />PH <br />PANIC HARDWARE <br />PL <br />PLATE <br />PLAM <br />PLASTIC LAMINATE <br />PLUMB <br />PLUMBING <br />PLYWD <br />PLYWOOD <br />PM <br />PARTTION MOUNTED <br />POC <br />POINT OF CONNECTION <br />PR <br />PAIR <br />PREP <br />PREPARE <br />PSF <br />POUNDS PER SQUARE FOOT <br />PSI <br />POUNDS PER SQUARE INCH <br />PT <br />PAINTED <br />PTN <br />PARTITION <br />PVC <br />POLYVINYL CHLORIDE <br />R <br />RISER, RADIUS <br />RD <br />ROOF DRAIN <br />REC <br />RECESSED <br />REF <br />REFRIGERATOR <br />REQ'D <br />REQUIRED <br />RM <br />ROOM <br />RO <br />ROUGH OPENING <br />RWL <br />RAIN WATER LEADER <br />SCHED <br />SCHEDULE <br />SCWD <br />SOLID CORE WOOD DOOR <br />SECT <br />SECTION <br />SF <br />SQUARE FEET <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />SM <br />SURFACE MOUNTED <br />SMS <br />SHEET METAL SCREW <br />SOV <br />SHUT OFF VALVE <br />SPEC <br />SPECIFICATION <br />SST <br />STAINLESS STEEL <br />STD <br />STANDARD <br />STL <br />STEEL <br />STRUCT <br />STRUCTURAL <br />T&B <br />TOP AND BOTTOM <br />TDE <br />TRAVEL DISTANCE TO EXIT <br />TDSC <br />TRAVEL DISTANCE TO SMOKE <br />COMPARTMENT <br />TEMP <br />TEMPORARY <br />ABBREVIATIONS <br />SYMBOL/ <br />ACCRONYM <br />DESCRIPTION <br />TO <br />TOP OF <br />TOB <br />TOP OF BEAM <br />TOC <br />TOP OF CURB <br />TOD <br />TOP OF DRAIN <br />TOP <br />TOP OF PARAPET <br />TOPL <br />TOP OF PLATE <br />TOR <br />TOP OF RIDGE <br />TOS <br />TOP OF STEEL <br />TOW <br />TOP OF WALL <br />TV <br />TELEVISION <br />TYP <br />TYPICAL <br />UC <br />UNERCUT <br />UNO <br />UNLESS NOTED OTHERWISE <br />LION <br />UNLESS OTHERWISE NOTED <br />VCT <br />VINYL COMPOSITE TILE <br />VERT <br />VERTIAL <br />VWE <br />VERIFY WITH EQUIPMENT <br />VWF <br />VERIFY WITH FIXTURE <br />W <br />WIDE FLANGE <br />W/ <br />WITH <br />W/O <br />WITHOUT <br />WD <br />WOOD <br />WH <br />WATER HEATER <br />W <br />WOOD WORK INSTITUTE <br />WIN <br />WINDOW <br />WP <br />WATERPROOF <br />WS <br />WOOD SCREW <br />WT <br />WEIGHT <br />WWF <br />WELDED WIRE FABRIC <br />x <br />BY <br />YD <br />YARD <br />studio <br />2211 E 7th Ave, Suite A, Tampa, Florida 33605 <br />P:239.357.4983 AA26002372 <br />Callfomia I Florida <br />PENINSULA ENGINEERING, INC <br />MEP&FP <br />2016 ALDEN ROAD <br />ORLANDO, FL 32803 <br />P: 407.246.1688 <br />LBA INTERIORS <br />INTERIOR DESIGN <br />5650 DTC PARKWAY <br />SUITE 100 <br />ENGLEWOOD, CO 80111 <br />P: 303.773.0436 <br />REVISIONS: <br />ARCHITECT OF RECORD: <br />JOSE A PEREZ, NCARB AIA <br />AR97653 o F F <br />01 <br />P F;P4, <br />IC <br />�o <br />2 <br />J, AR97653 <br />K01- <br />mllml = <br />• <br />TITLE: <br />CHILLS HEALTH & REHAB <br />CENTER <br />FINISH UPGRADE - SKILLED <br />NURSING FACILITY <br />PROJECT ADDRESS: <br />7350 DAIRY RD. ZEPHYRHILLS, FL 33540 <br />PROJECT NUMBER: <br />FLTSP16003 <br />ISSUED DATE: <br />12/16/2016 <br />SHEET TITLE: <br />ABBREVIATIONS, SYMBOLS & <br />GENERAL NOTES <br />GOml <br />©2016 <br />