Laserfiche WebLink
DESK-zN GfRITEfRIA <br />D1 ALL WORK SHALL CONFORM TO AT LEAST THE MINIMUM STANDARDS OF <br />THE FLORIDA BUILDING CODE, 2004 EDITION, WITH 2O06 REVISIONS. <br />D2 FOR DESIGN LOAD VALUES, SEE SPECIFIC PLANS. <br />FOUNDATION SHEET PG6101 <br />ROOF FRAMING SHEETS PC5101 <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE STRUCTURAL PLANS <br />D3 AND SPECIFICATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE <br />BUILDING CODE. <br />EVERY REASONABLE EFFORT HAS BEEN MADE TO ENSURE <br />D4 COORDINATION BETWEEN THESE DWGS AND THE BOUND STRUCTURAL <br />SPECIFICATIONS. SHOULD THERE BE ANY DISCREPANCIES, THE <br />CONTRACTOR SHALL REQUEST A CLARIFICATION IN WRITING. <br />GENERAL <br />G1 THE GENERAL CONTRACTOR SHALL REVIEW AND DETERMINE THAT <br />DIMENSIONS ARE COORDINATED BETWEEN ARCHITECTURAL AND <br />STRUCTURAL DRAWINGS PRIOR TO FABRICATION OR START OF <br />CONSTRUCTION. <br />G2 THE GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE STRUCTURE, THE WORK PERSONS AND <br />OTHER PEOPLE DURING CONSTRUCTION. HE SHALL SUPERVISE AND <br />DIRECT THE WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION. <br />G3 NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE <br />REDUCED IN STRENGTH. <br />G4 THE GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL, <br />MECHANICAL AND ELECTRICAL DRAWINGS FOR ANCHORED, EMBEDDED AND <br />SUPPORTED ITEMS WHICH AFFECT THE STRUCTURAL DRAWINGS AND NOTIFY <br />THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES, <br />G5 ALL SUBMITTAL SETS SHALL CONSIST OF A MAXIMUM OF (5) COPIES. <br />ANY ADDITIONAL COPIES WILL BE DISCARDED. <br />G6 ANY SUBMITTALS RECEIVED BY ARCH/ENG THAT HAVE NOT BEEN <br />CHECKED BY THE GC AND HIS SUBCONTRACTOR SHALL BE <br />RETURNED WITHOUT REVIEW. <br />G� ALL SECTIONS AND DETAILS SHALL BE CONSTRUED TO BE TYPICAL <br />OR SIMILAR UNLESS ANOTHER SECTION OR DETAIL IS NOTED, <br />GO ANY CONFLICTS BETWEEN THE SPECIFICATIONS AND DESIGN <br />DRAWINGS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF <br />THE ARCHITECT. THE MORE STRINGENT REQUIREMENTS SHALL <br />GOVERN UNLESS DETERMINED OTHERWISE BY THE ARCHITECT. <br />G9 BBM STRUCTURAL ENGINEERS ASSUMES NO RISK OR LIABILITY FOR <br />THE SITE SAFETY OR WELL-BEING OF ANY CONTRACTOR, <br />SUBCONTRACTOR NOR THEIR EMPLOYEES DURING THE CONSTRUCTION <br />OF THE PROJECT CONTAINED IN THESE DOCUMENTS. <br />1=OUND,4T I ONS <br />F1 A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM <br />INDUSTRY -STANDARD SOIL DENSITY TESTS TO ENSURE <br />CONFORMANCE WITH GEOTECHNICAL SOILS REPORT. SUBMIT <br />REPORTS TO ARCHITECT AND ENGINEER. <br />F2 CONTRACTOR, IN CONJUNCTION WITH GEOTECHNICAL FIELD <br />REPRESENTATIVE, SHALL DETERMINE IF ANY UNSUITABLE CONDITIONS <br />ARE DISCOVERED DURING EXCAVATION WHICH WOULD PREVENT <br />ATTAINMENT OF THE DESIGN SOIL PRESSURE RECOMMENDED BY THE <br />SOILS REPORT. <br />F3 FOR FOUNDATION DESIGN VALUES, SEE FOUNDATION SCHEDULE. <br />6L,45 ON GRADE <br />6OG1 UNLESS NOTED OTHERWISE IN THE GEOTECHNICAL REPORT, COMPACT <br />INTERIOR FILL TO'B5% OF MODIFIED PROCTOR MAXIMUM DRY DENSITY <br />(ASTM D1557). SOIL COMPACTION SHALL BE FIELD -CONTROLLED BY A <br />REPRESENTATIVE TECHNICIAN OF A QUALIFIED LABORATORY, EACH <br />LAYER OF FILL SHALL NOT EXCEED 12" THICK AND SHALL BE <br />COMPACTED PRIOR TO PLACEMENT OF NEXT LAYER. <br />5OG2 MAXIMUM SPACING OF CONTROL JOINTS (Le. SAWCUT JOINT OR <br />CONSTRUCTION JOINT) SHALL BE AS SET IN THE TABLE BELOW, OR AS <br />NOTED ON PLANS. THE MORE STRINGENT SHALL APPLY. PATTERNS <br />SHALL BE APPROXIMATELY SQUARE WITH A RATIO OF LONG SIDE TO <br />SHORT SIDE NOT EXCEEDING 1.5 TO 1. <br />SLAB <br />THICKNESS <br />(IN) <br />* 3/4" OR LARGER <br />AGGREGATE <br />SPACING (FT) <br />4 <br />12 <br />5 <br />13 <br />6 <br />14 <br />7 <br />16 <br />8 <br />18 <br />9 <br />19 <br />10 <br />20 <br />* MIX DESIGNS CONTAINING <br />AGGREGATE LESS THAN 3/4" <br />ARE NOT ACCEPTABLE. <br />* * SAWCUT SLAB AS SOON AS <br />AGGREGATE DOES NOT <br />DISLODGE (MUST BE <br />WITHIN 12 HOURS OF <br />CONCRETE PLACEMENT). <br />SOG3 GENERAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF SJ'S <br />AND CJ'S WITH ARCHITECTURAL FLOOR FINISHES TO ENSURE SLAB JOINTS <br />DO NOT READ THROUGH. <br />5OC34 SLAB THICKNESS SHALL BE INGREASED AS REQUIRED TO PROVIDE <br />ADEQUATE SUPPORT FOR CRANE LOADS WITHOUT CRACKING SLAB. <br />1VIECH,4NICAL 1=,4STENER6 <br />MF1 EXPANSION ANCHORS SHALL BE I'POWER-STUD" BY RAWL OR "TRUBOLT" <br />BY ITW RAMSET/REDHEAD OR ENGINEER -APPROVED EQUAL. <br />MF2 ADHESIVE ANCHORS SHALL BE ''POWER -FAST" BY RAWL OR "EPCON" BY <br />ITW RAMSET/REDHEAD OR ENGINEER -APPROVED EQUAL. <br />MF3 MASONRY SCREWS SHALL BE "TAPPERS" BY RAWL OR "TAPCON" BY ITW <br />RAMSET/REDHEAD OR ENGINEER -APPROVED EQUAL. <br />MF4 POWDER -ACTUATED FASTENERS (PAF) SHALL BE BY ITW <br />RAMSET/REDHEAD, HILTI OR ENGINEER -APPROVED EQUAL. <br />MF5 REFER TO LIGHT -GAGE FRAMING NOTES (IF APPLICABLE) FOR <br />ADDITIONAL INFORMATION. <br />MF6 CARBON -STEEL EXPANSION ANCHORS SHALL HAVE A ONE-PIECE <br />ANCHOR BODY WITH A LENGTH IDENTIFICATION CODE. THE ANCHORS <br />SHALL HAVE AN EXPANSION MECHANISM WHICH CONSISTS OF A PAIR OF <br />INTERLOCKING INDEPENDENT WEDGES. CARBON STEEL COMPONENTS <br />SHALL BE PLATED ACCORDING TO ASTM SPECIFICATION B 6.33. <br />EXPANSION ANCHORS MUST MEET THE DESCRIPTION IN FEDERAL <br />SPECIFICATION FF-8-325 FOR CONCRETE EXPANSION ANCHORS, <br />MF7 ALL FASTENERS SHALL BE INSTALLED PER THE MANUFACTURER'S <br />RECOMMENDATIONS. REFER TO LIGHT GAGE METAL FRAMING NOTES (IF <br />APPLICABLE) FOR ADDITIONAL INFORMATION. <br />L (GHTGAGE 1`l1=TAL 1=RA1- I ING <br />LMF1 A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM <br />INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH <br />PLANS AND SPECIFICATIONS (IF PROVIDED). SUBMIT REPORTS TO <br />ARCHITECT AND ENGINEER_ <br />LMF2 CONNECT STEEL STUDS AND TRACKS TO 436 STEEL OR CONCRETE <br />WITH (2) FASTENERS (PAF) AT EACH STUD, AND CONNECT STEEL <br />STUDS AND TRACKS TO EACH OTHER WITH (2) *8-18 SCREWS AT <br />EACH STUD (TYPICAL UNLESS NOTED OTHERWISE). SEE <br />ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND EXTENTS <br />OF STEEL STUD WORK. <br />NOTE: "POWDER ACTUATED FASTENER (PAF)" REFERS TO 0.1454, <br />SHANK DOMED -HEAD, LOW -VELOCITY POWDER ACTUATED <br />FASTENERS AS MANUFACTURED BY POWERS RAWL OR APPROVED <br />EQUAL WITH MINIMUM CAPACITIES AS FOLLOWS: <br />IN 3000 PS 1 <br />CONCRETE: 1 1/2'' PENETRATION = 185* PULLOUT 4 225* SHEAR <br />IN 436 STEEL: 1/4" MATERIAL = 430* PULLOUT 4 660* SHEAR <br />(PIN MUST FULLY PENETRATE THE MATERIAL BY <br />1/4" MINIMUM) <br />�UI�T�IUJR�AIL���►1�R'�A1�►CO�T�ES� <br />L IG4TG;AGE 1 IETAL FfRA„f INCH <br />LMFS STEEL STUDS SHALL MEET FOLLOWING DESIGN CRITERIA: GALV G-60 <br />45TM A525, MINIMUM YIELD STRESS SHALL BE 50,000 PSI FOR 12ga, 14ga, <br />16ga AND 33000 PSI FOR 18ga 4 20ga. <br />STUD SIZE <br />EFFECTIVE <br />MINIMUM I <br />EFFECTIVE <br />MINIMUM S <br />3 5/8"x16 GA <br />.854g <br />.4388 <br />3 5/8"x18 GA <br />.6941 <br />.3652 <br />3 5/5"x20 GA <br />.5354 <br />.2608 <br />4"x16 GA <br />1.0152 <br />.502-t <br />4"x18 GA <br />3-122 <br />4"x20 GA <br />6i22 <br />.2589 <br />6 "x16 GA <br />2.SO33 <br />.8812 <br />6"x18 GA <br />2.2ro-15 <br />.7328 <br />6 "x20 GA <br />1.1421 <br />.5234 <br />8"x14 GA <br />6.94-17 <br />1.100-1 <br />S"x16 GA <br />5.6294 <br />1.34-10 <br />8"x18 GA <br />4.5454 <br />1.10-18 <br />0"40 GA <br />3.4876 <br />.6684 <br />NOTES: <br />1. NOT ALL SIZES MAY BE USED. SEE PLANS AND SECTIONS FOR <br />SIZES) REQUIRED. (51ZE6 AND GAGES ON STRUCTURAL DWGS <br />SHALL GOVERN OVER ARCHITECTURAL DWGS) <br />2. ALL SIZES SHALL HAVE 1-5/8" FLANGES, <br />LMF4 BRACING DURING CONSTRUCTION: <br />PROVIDE 1 1/2" GOLD -ROLLED CHANNELS OR HORIZONTAL STRAP <br />BRACING FOR WALLS IMMEDIATELY AFTER STUDS ARE ERECTED. <br />LMFS EXECUTION: <br />POSITION STUDS VERTICALLY IN RUNNERS AND SPACE NO GREATER THAN <br />16". SECURELY ANCHOR EACH STUD TO RUNNER WITH (4) *8-18 <br />LOW -PROFILE SCREWS, TWO AT TOP AND TWO AT BOTTOM, WITH ONE <br />SCREW IN EACH FLANGE. TRACKS SHALL BE SECURELY ANCHORED TO <br />THE SUPPORTING STRUCTURE AS SHOWN ON THE PLANS. AT TRACK BUTT <br />JOINTS, ABUTTING PIECES OF TRACK SHALL BE SECURELY ANCHORED TO <br />A COMMON STRUCTURAL ELEMENT, OR THEY SHALL BE BUTT -WELDED OR <br />SPLICED TOGETHER. JACK STUDS OR CRIPPLES SHALL BE INSTALLED <br />BELOW WINDOW SILLS, ABOVE WINDOW AND DOOR HEADS, AT FREE <br />STANDING STAIR RAILS, AND ELSEWHERE TO FURNISH SUPPORT, AND <br />SHALL BE SECURELY ATTACHED TO SUPPORTING MEMBERS. PROVISIONS <br />FOR STRUCTURE VERTICAL MOVEMENT SHALL BE PROVIDED WHERE <br />INDICATED ON THE PLANS. SPLICES IN AXIALLY LOADED STUDS SHALL <br />NOT BE PERMITTED. <br />LMF6 EXTERIOR SHEATHING: <br />ATTACH GYPSUM SHEATHING TO EXTERIOR OF EACH STUD WITH I" <br />TYPE(S) 5-12 COATED SCREWS SPACED 3/5" FROM ENDS AND EDGES <br />AND AT APPROXIMATELY 8" OC. <br />LMF-1 LATERAL BRACING (HORIZONTAL BRIDGING) FOR WALLS: <br />(NOTE: IF NON -LOAD -BEARING WALLS (PARTITION WALLS OR CURTAIN <br />WALLS) HAVE SHEATHING ON BOTH SIDES, LATERAL BRACING IS NOT <br />REQUIRED.) <br />ENSURE BOTH STUD FLANGES ARE ATTACHED TO TOP AND BOTTOM <br />RUNNER FLANGES. HORIZONTAL BRIDGING MUST BE INSTALLED AT <br />SPACING NOT TO EXCEED 48" OC FOR AXIAL LOAD BEARING WALLS <br />AND 60" OC MEASURED VERTICALLY FOR NON -LOAD -BEARING WALLS <br />CARRYING WIND LOAD ONLY. (TYPICAL FOR ALL OPTIONS BELOW.) <br />16ga V-BAR BRIDGING <br />ATTACHED TO BOTH <br />FLANGES, SEE NOTES <br />FOR SPACING. <br />(1) *10 <br />(TYP) <br />Qr �' MTL STUD - SEE PLAN <br />HORIZONTAL BRIDGING - OPTION #1 <br />5/8" TYPE 5-12 <br />LOW PROFILE <br />HEAD SCREWS <br />ID BRIDGING <br />RUNNER) <br />1 1/2"-20 GAGE <br />STRAP BRIDGING <br />STL STUD <br />HORIZONTAL BRIDGING CONSISTS OF GUT -TO -LENGTH RUNNER FOR <br />SOLID BRIDGING AND STEEL STRAPS ON BOTH SIDES OF STUD, <br />SOLID BRIDGING IS PLACED AT EA END OF WALL, ADJACENT TO <br />WALL OPENINGS AND 8'-O" OC MAX, MEASURED VERTICALLY. <br />RUNNER HAS WEB FLANGE BENT AT EACH END AND IS SECURED TO <br />EACH STUD FLANGE WITH ONE 5/8" TYPE 5-12 LOW PROFILE SCREW. <br />STRAP BRIDGING OF 1 1/2" WIDE BY 20ga STEEL IS FASTENED TO <br />EACH STUD FLANGE WITH ONE 5/8" TYPE 5-12 SCREW AND TO EACH <br />RUNNER FLANGE WITH FOUR SCREWS. <br />HORIZONTAL BRIDGING - OPTION #2 <br />1 1/2" COLD ROLLED CHANNELS MAY BE USED IN LIEU OF ABOVE <br />DETAIL TO BRACE STUDS LATERALLY. CHANNELS ARE INSERTED <br />THROUGH STUD WEB HOLES AND SECURED WITH SCREW -ATTACHED <br />1 1/2 "4 "x16ga CL IF ANGLES CUT TO LENGTH 1/4" LESS THAN STUD WIDTH. <br />HORIZONTAL BRIDGING - OPTION #3 <br />LMFS METAL STUD INSTALLATION: <br />METAL STUDS SHALL EXTEND INTO ALL TRACKS UNTIL IT IS WITHIN 1/2" <br />OF THE TRACK WEB. <br />NO METAL STUD TRACK SHALL EXTEND PAST THE EDGE OF THE <br />SUPPORT MORE THAN ONE THIRD OF ITS WIDTH ( e.g. A 6" TRACK MAY <br />EXTEND BEYOND THE EDGE OF SUPPORT A MAX OF (o/3=2"). <br />STEEL ROOF DECK <br />RD1 SEE ROOF FRAMING PLAN(S) FOR STEEL DECK ATTACHMENT TO <br />STRUCTURE. <br />RD2 STEEL ROOF DECK UNITS SHALL BE FABRICATED FROM STEEL <br />CONFORMING TO SECTION A3 OF THE LATEST EDITION OF THE AMERICAN <br />IRON AND STEEL INSTITUTE, SPECIFICATIONS FOR THE DESIGN OF COLD - <br />FORMED STEEL STRUCTURAL MEMBERS. THE STEEL USED SHALL HAVE A <br />MINIMUM YIELD STRENGTH OF 33 KSI (230 MPa). <br />RD3 ALL FIELD WELDING OF DECK SHALL BE IN STRICT CONFORMANCE WITH <br />ANSI/AWSDI3 STRUCTURAL WELDING CODE. <br />RD4 GALVANIZING SHALL CONFORM TO A6TM-A653, STRUCTURAL QUALITY <br />AND FEDERAL SPEC, QQ-5-715. <br />RD5 SEE CHART BELOW FOR MINIMUM SECTION PROPERTIES REQUIRED FOR <br />STEEL DECK. PROPERTIES SHOWN ARE REPRODUCED FROM THE <br />VULCRAFT MANUAL. <br />ROOF DECK <br />DECK <br />TYPE <br />DESIGN <br />THICK <br />I <br />ins/ft <br />Sp <br />in3/ft <br />Sn <br />in3/ft <br />522 <br />0.0295 <br />0.169 <br />0.186 <br />0.192 <br />B20 <br />0.0358 <br />0.212 <br />0.234 <br />0.24i <br />B18 <br />I 0.0474 <br />0.292 <br />0.318 <br />0.32-1 <br />fi R1=-1=,45R1 CATER L IG�4T STEEL TRUSSI=S <br />57 A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM <br />INDUSTRY STANDARD INSPECTIONS TO ENSURE CONFORMANCE WITH <br />PLANS AND SPECIFICATIONS CIF PROVIDED). SUBMIT REPORTS TO <br />ARCHITECT AND ENGINEER. <br />ST2 SHOP DRAWING SUBMITTALS, INCLUDING, BUT NOT LIMITED TO, PLANS, <br />DETAILS AND CALCULATIONS SHALL BE SUBMITTED TO ARCHITECT FOR <br />REVIEW PRIOR TO FABRICATION. CALCULATIONS SHALL BE SIGNED AND <br />SEALED BY AN ENGINEER REGISTERED IN THE SAME STATE AS PROJECT <br />LOCATION. "BBM STRUCTURAL ENGINEERS" WILL REQUIRE THAT THE <br />ENGINEERED DRAWINGS FOR THE STEEL TRUSSES BE REVIEWED FOR <br />COMPATIBILITY WITH THE DESIGN INTENT OF THE STRUCTURE PRIOR TO <br />FABRICATION. ANY AND ALL COSTS ASSOCIATED WITH FABRICATING <br />TRUSSES FROM SUBMITTALS NOT BEARING OUR SHOP DRAWING STAMP <br />AND APPROVAL WILL BE THE SOLE RESPONSIBILITY OF THE GENERAL <br />CONTRACTOR, <br />5T3 SEE ROOF FRAMING PLANS AND ARCHITECTURAL DRAWINGS FOR EXTENT <br />AND SLOPES OF STEEL TRUSSES. <br />5T4 ALL TRUSSES SHALL BE DESIGNED BY A SPECIALTY ENGINEER WITH A <br />MINIMUM OF (5) YEARS EXPERIENCE IN SIMILAR TYPE STRUCTURES. <br />ST5 ALL TRUSSES SHALL BE TEMPORARILY AND PERMANENTLY BRACED AS <br />REQUIRED BY TRUSS MFR. BRACING AND BRIDGING BY TRUSS MFR. <br />5T6 MINIMUM THICKNESS FOR TOP CHORD OF ALL TRUSSES SHALL BE 18 GA. <br />ST7 THE ROOF FRAMING PLAN SHOWN HEREIN 16 A GRAPHICAL <br />REPRESENTATION ONLY. REFER TO TRUSS SUBMITTALS FOR ACTUAL <br />LAYOUT, TRUSS PROFILES AND CONNECTION REQUIREMENTS AT ALL TRUSS <br />SUPPORTS, <br />STS ALL TRUSS -TO -TRUSS 4 TRUSS TO STRUCTURE CONNECTIONS SHALL BE <br />DESIGNED AND DETAILED BY TRUSS MANUFACTURER. CONNECTIONS SHALL <br />BE DESIGNED FOR DEAD, LIVE AND WIND (BOTH UPLIFT 4 LATERAL) <br />LOADS, <br />ST9 TRUSSES SHALL BE SHOP FABRICATED, INCLUDING ANY FIELD SPLICE <br />CONNECTION COMPONENTS AND SHIPPED TO SITE IN MAXIMUM LENGTHS <br />AND HEIGHTS. FIELD FABRICATION OF TRUSSES WILL NOT BE PERMITTED. <br />STIO ALL TRUSS MEMBERS SHALL BE GALVANIZED METAL STUD STOCK AND <br />GALVANIZED SHEET OF SIZES AND GAGES TO BE DETERMINED BY THE <br />MANUFACTURER'S STRUCTURAL ANALYSIS. GALVANIZED CUSTOM SHAPE <br />AND CONNECTOR SYSTEMS SPECIFICALLY DESIGNED FOR USE IN TRUSSES <br />WILL BE ACCEPTABLE. <br />STII REVIEW ARCHITECTURAL FLOOR PLANS FOR OPERABLE WALLS THAT <br />ARE SUSPENDED FROM THE TRUSSES, ANALYSIS FOR CLOSED, <br />PARTIALLY OPEN AND OPEN POSITION LOAD CURVES IS REQUIRED, <br />REFER TO WALL MANUFACTURER FOR SPECIAL DEFLECTION CRITERIA. <br />6T12 REVIEW ARCHITECTURAL REFLECTED CEILING PLANS AND SECTIONS FOR <br />SPECIAL CEILING CONDITIONS, INCLUDING CEILING SLOPES, TROFFERS, <br />COFFERS, TRAYS, STEPS AND OTHER SPECIAL FEATURES. <br />573 THE SUPPORTS FOR SCISSOR, ARCHED CHORDS OR ANY OTHER SIMILAR <br />TYPE TRUSS, UNLESS NOTED OTHERWISE, SHALL BE DESIGNED WITH A <br />PINNED CONNECTION AT ONE END AND A HORIZONTAL ROLLER AT THE <br />OTHER END. THE SUPPORTING STRUCTURE, UNLESS NOTED OTHERWISE, HAS <br />NOT BEEN DESIGNED FOR ANY GRAVITY LOAD HORIZONTAL FORCE DUE <br />TO DEFLECTION. DO NOT DESIGN THESE TYPE OF TRUSSES WITH PINNED <br />SUPPORTS EACH END. <br />CONCRETE AND RE INI=ORC ING <br />C1 A CERTIFIED TESTING AGENCY SHALL BE ENGAGED TO PERFORM <br />INDUSTRY STANDARD TESTING INCLUDING SLUMP TESTS AND CYLINDER <br />BREAKS TO ENSURE CONFORMANCE WITH PLANS AND SPECIFICATIONS <br />CIF PROVIDED). SUBMIT REPORTS TO ARCHITECT AND ENGINEER. <br />C2 CONCRETE WORK SHALL CONFORM TO ACI 318-02 BUILDING CODE <br />REQUIREMENTS FOR STRUCTURAL CONCRETE. <br />C3 ALL CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES: <br />C4 <br />C5 <br />C6 <br />C-1 <br />LOCATION <br />DAY <br />SLUMP <br />COARSE <br />STRENGTH <br />STRENGTH <br />AGGREGATES) <br />FOUNDATIONS <br />3000 PSI <br />4" +/- 1" <br />1" <br />SLAB -ON -GRADE: FOOT TRAFFIC <br />3000 PSI <br />4" +/- 1" <br />1" <br />TIE BEAMS AND TIE COLUMNS <br />3000 PSI <br />(MAX 50' BETWEEN COLD JOINTS) <br />BEAMS AND COLUMNS <br />4000 PSI <br />4" 1" <br />1" <br />ELEVATED SLABS (MTL DECK) <br />3000 PSI <br />4" +/- 1" <br />3/8" 4111 <br />FILLED CELL, PRECAST <br />COARSE <br />LINTELS 4 BOND BEAM GROUT <br />2500 PSI <br />8" TO 11" <br />GROUT: 3/8" <br />FINE GROUT: <br />(ASTM C4-1(o) - SEE NOTE 2 <br />NONE <br />NOTES: <br />I. SLUMP FOR RAMPS AND SLOPING SURFACES SHALL NOT EXCEED 4" <br />2. SEE MASONRY NOTE M21 FOR TESTING REQUIREMENTS OF GROUT TO <br />BE USED TO FILL GORES OF CMU. <br />CONCRETE MIX DESIGN SUBMITTALS: <br />1- EACH MIX DESIGN SHALL BE LABELED TO INDICATE THE AREA IN WHICH <br />THE CONCRETE IS TO BE PLACED (I.E. FOUNDATIONS, SLAB- ON -GRADE, <br />COLUMNS, ETC.). FAILURE TO DO SO WILL CAUSE DELAY AND/OR <br />REJECTION OF SUBMITTALS. <br />2. PROPOSED MIX DESIGN SHALL BE IN ACCORDANCE WITH METHOD <br />1 OR METHOD 2 OF ACI 301. PROVIDE SUPPORTING DATA IN <br />TABULAR FORM FOR EACH SEPARATE PROPOSED MIX. <br />3. SUBMIT CONCRETE MIX DESIGN FOR EACH PROPOSED CLASS <br />OF CONCRETE, <br />REBAR SHALL CONFORM TO ASTM-615 GRADE 60. WELDED WIRE <br />FABRIC SHALL CONFORM TO ASTM A-185 AND SHALL BE LAPPED <br />MINIMUM ONE MESH + 2" WHERE SPLICED. ALL REINFORCING SHALL BE <br />DOMESTICALLY PRODUCED. <br />SPLICES AND ANCHORAGE OF REINFORCING SHALL BE AS FOLLOWS <br />(UNLESS OTHERWISE NOTED): <br />WELDED WIRE FABRIC: 8" <br />ALL OTHER: 48 DIA (12'' MIN) <br />REINFORCEMENT IN WALLS, FOOTINGS AND BEAMS SHALL BE CONTINUOUS <br />AND LAPPED 48 BAR DIA AT SPLICE UNLESS OTHERWISE NOTED. HOOK <br />AND LAP ALL CORNER AND INTERSECTING BARS. (SEE REINF <br />DEVELOPMENT DETAIL). <br />484> LAP SPLICE (TYP) <br />eda Id• <br />EXTEND INTERIOR BARS TO 1; a•° <br />FAR FACE (TYP, NO NOOKS ° <br />OR CORNER BARS REQ'D) <br />I,d. <br />STD HOOK (TYP) I ` <br />I.•d a 1.`d. <br />CORNER BAR (TYP) - I `` Oil <br />MATCH OF HORIZONTAL 8 (TYP) <br />BARS (TYP) <br />e d <br />L <br />a <br />SEE GEN NOTES FOR <br />REQ'D COVER (TYP) <br />CORNER INTERSECTION <br />REINF DEVELOPMENT DETAIL <br />CONCRETE AND REINFORCING CONT'D <br />C8 COVER FOR REINFORCING SHALL BE AS FOLLOWS: <br />C9 <br />CONCRETE CAST AGAINST AND <br />PERMANENTLY EXPOSED TO EARTH: <br />311 <br />CONCRETE EXPOSED TO EARTH OR WEATHER: <br />*6 THRU *18 BARS: <br />2" <br />*5 BAR, W31 OR D31 WIRE AND SMALLER; <br />1 1/2" <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER: <br />SLABS, WALLS, JOISTS: <br />*14 AND *18 BARS: <br />1 1/2" <br />*11 BAR AND SMALLER: <br />3/4" <br />BEAMS, COLUMNS: <br />PRIMARY REINF, TIES, STIRRUPS, SPIRALS: <br />1 1/2" <br />SHELLS, FOLDED PLATE MEMBERS: <br />*6 BAR AND LARGER: <br />3/4" <br />*5 BAR, W31, OR D31 WIRE AND SMALLER: <br />1/2" <br />STEPPED FOOTING DETAIL (IF REQUIRED): <br />SEE PLAN FOR 36 O LAP <br />LOCATION 2" CLR T/ FTG <br />dk EL SEE <br />FDN <br />d ` PLAN <br />T/ FTG <br />S , dCLR <br />EL EE (TYP) <br />FDN <br />PLAN <br />FTG REINF (SEE SCH) <br />QI <br />REINF SAME AS <br />THAT IN FDN SCH <br />MATCH <br />FTG <br />THICKNESS FTG REINF (SEE SCH) <br />DETAIL - STEPPED FOOTING <br />PENETRATION DETAILS: <br />TYP FTG REINF NOTE: <br />PIPE MUST BE 90' <br />TY (±10°) TO WALL FTG <br />FTGTCH REINFP <br />WRAP PIPE WITH A MINIMUM 1" THICK <br />MIN 18" <br />COMPRESSIBLE PIPE INSULATION FOR <br />ENTIRE WIDTH OF FTG + 4" MIN EACH SIDE <br />T/ FTG EL <br />SEE FDN <br />e <br />PLAN <br />d° <br />MIN <br />OPTION <br />1 A( FTG AFTER P I P E� <br />TYP FTG REINF NOTE: <br />PIPE MUST BE 90' <br />MATCH TYP (±10') TO WALL FTG <br />FTG RE INF <br />SLEEVE (2 SIZES LARGER <br />MIN 18" <br />THAN PIPE) FOR ENTIRE WIDTH <br />OF FTG + 4" MIN EACH SIDE <br />T/ FTG EL <br />" <br />d <br />SEE FDN <br />d d <br />d e <br />n <br />PLAN <br />d <br /><Q <br />a <br />�i� <br />j <br />a j jja 1 <br />j <br />10 6 <br />MIN <br />OPTION <br />1 B (FTG BEFORE PIPE <br />WALL FOOTING, SEE <br />WALL - SEE <br />FOUNDATION PLAN <br />FOUNDATION <br />AND SCHEDULE FOR <br />PLAN <br />SIZE AND <br />REINF. <br />_ <br />(k <br />0 <br />HOOK <br />EDGE / ADD'L BAR *5x5'-O" <br />BAR P LAN V1 EW <br />/ DOWNSPOUT, FTG 4 WALL <br />COORD INATE WALL - SEE <br />WITH ARGH'L FOUNDATION PLAN <br />AND CIVIL DWGS <br />I <br />NOTE: 41DD'L BAR, <br />CONFIGURATION OF SEE ABOVE <br />PIPE MAY VARY. _ T/ FTG EL <br />COORD W/ CIVIL <br />DWGS. <br />z SEE FDN PLAN <br />' ' Q <br />L <br />W <br />' W U <br />3" CLR <br />SEE FDN SCH <br />(TYP) <br />OPTION 2 (NOTCH IN FTG) <br />DETAIL - FOOTING <br />PENETRATIONS <br />�4ANDRA I L <br />HRl HANDRAILS SHALL BE DESIGNED PER APPLICABLE BUILDING CODE <br />(SEE D1). FABRICATOR SHALL SUBMIT SHOP DRAWINGS SIGNED AND <br />SEALED BY A REGISTERED FLORIDA ENGINEER TO THE ENGINEER OF <br />RECORD FOR APPROVAL. <br />B • B • M <br />m <br />0 <br />B•B•M <br />STRUCTURAL ENGINEERS $ <br />Orlando Boca Raton <br />Q <br />P:407.645.3423 0 <br />F:407.645 3790 = <br />1912 Boothe Circle • Suite 100 Of <br />Longwood, FL 32750 0 <br />bbma.com <br />EB5343 <br />Bora Erbilen P.E. #55996 <br />ENGINEER HEREBY EXPRESSLY RESERVES HIS <br />COMMON LAW COPYRIGHT AND OTHER PROPERTY <br />RIGHTS IN THESE PLANS, THIS DESIGN AND <br />DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED, <br />OR COPIED IN ANY FORM OR MANNER WHATSOEVER <br />WITHOUT FIRST OBTAINING THE EXPRESSED WRTTEN <br />PERMISSION AND CONSENT OF "BURTON BRASWELL <br />MI DDLEBROOKS ASSOCIATES", NOR ARE THEY TO BE <br />ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING <br />SAID WRITTEN PERMISSION AND CONSENT. <br />U <br />z <br />w <br />z <br />O <br />N0 <br />Lr.Ln <br />V <br />Q <br />U_w <br />Z 00 <br />W <br />�Z <br />U c�O <br />CwQ JU <br />GQWLL <br />LU < LLJ <br />N2W <br />W �MH� <br />U <br />J <br />J <br />r <br />w <br />M <br />06 <br />U) <br />0 <br />00< <br />� J <br />Q J Z <br />X�,0 <br />� <br />JYMU <br />�U)a-0 <br />U <br />o <br />Uj <br />Q-0Na <br />a <br />W <br />w <br />0 <br />z <br />J I!� <br />~ I <br />C) <br />U) <br />J <br />L1J <br />W z <br />J <br />� w <br />w V W <br />U) <br />0 <br />0 <br />0 <br />E <br />U) <br />x <br />a <br />U <br />Q <br />W <br />J <br />W <br />W <br />O <br />I� <br />Z <br />O <br />O <br />� <br />o <br />W <br />W <br />CD <br />z <br />V <br />LU <br />N <br />WC) <br />M <br />0 <br />Q <br />Q <br />2 <br />rS001 <br />File=C: \Users\JBROWE-1.BBM\AppData\Local\Temp\AcPublish_2756\07122_PCS001.dwg Tab=PCS001 Date/Time= Apr 17, 2008 - 10: 43am Plot by jbrower <br />