Laserfiche WebLink
in <br />N <br />O O <br />O <br />O <br />SEE NOTE NEATLY SAWCUT END OF EVERY NOTE: <br />♦� M o <br />OTHER COURSE TO ALLOW CELL <br />ROOF TRUSSES NOT SHOWN <br />FOR CLARITY. <br />TO FILL W/ CONCRETE <br />E ❑NOTES: STEEL BM (HIGH) <br />SEE ARCH DUGS STL COL - SEE FDN PLAN 1. TIE COLUMNS (TC'S) SHALL <br />EXTEND TO NOTE: <br />FOR FINISH I I SECTION A -A OR ROOF LEVELNUNO. NEXT FLOOR COL CAP > MAY NOT <br />I I 1 1 (4) 5/5"4 432F7N BE REQUIRED, COLS <br />3" MIN ALL 1 1 I BASE fE AND ANCHOR SEE SCH 2. PROVIDE REVEAL (COORD SIZE MAY EXTEND UPWARD. <br />I I I I BOLTS - SEE SCH FOR SIZE AND SHAPE W/ ARCH) AT ALL BOLTS (TYP) <br />AROUND I I I I EXPOSED CONDITIONS. DO NOT <br />CO <br />PEDESTAL. I I 1 1/2" NON -SHRINK GROUT ALLOW TIE COLUMN CONCRETE <br />I PASTE TO PASS BEYOND THE 1 _0 <br />REINF W/ 05 � I I I I -� �, I I HSS 3x3x3/16 W/ <br />REVEAL. I I 1/2"x5 1/2"xO'-9" CAP PLATE <br />EACH CORNER 4 I <br />PLATES TOP <br />EJ (TYP) ° I _ SEE Fl"IG PLAN <br />MAX �" OG #3 I T/ PEDESTAL = I BOTTOM <br />TIES 4" OG FIN FLR EL = 0'-0" <br />.d .. °° .d °• 1 1/2" III III III \ <br />e d- <br />a '. <br />T/ EXT WALKUJAY EL m TIE COL (SEE SCH CLR <br />VARIES -SEE ARCH ° ;. a FOR SIZE REINF) <br />� CIVIL DUJGS <br />(U TIE IN FTG l CLR <br />\, T/ FTG EL <br />a° EXTEND HORIZ JOINT N 1 1 4 I I <br />?a `. SEE FDN PLAN REINF 6" INTO COL <br />I I REF PCS?01 I I <br />_ SHEAR iF I STL BM -SEE <br />(_ a p �. a d °°..°° ° ° ° ° I <br />d M r <br />d: SEE SCH II <br />w u i� I 1 /2 FMG PLAN <br />= 40 BAR DIA LAP SPLICE FOR TIE I I <br />e O <br />Z� &F <br />3" CLR (TYP) O = MASONRY LAP SPLICES E R HSS COL - SEE <br />SEE FDN SGH U FDN PLAN <br />CO SEE GENERAL NOT <br />TG1 I I <br />(TYP) p d a a d A (6) 'q VER7 <br />Z U pOWELS W/ STD HOOK #3 TIES -a 12" OC <br />d ° TO MATCH VERT REINF <br />SN3LE=PLATE SHEAR CONNECTM SCHEDULE <br />(SHOP -WELDED, FIELD -BOLTED) <br />BEAM <br />PLATE <br />PLATE <br />FILLET WELD <br />CAPACITY (SIPS) <br />DEPTH; I <br />(SEE <br />OF 3/4" <br />DIA A325N <br />LENGTH "L" <br />THICKNESS <br />SIZE <br />PLAIN) <br />BOLTS <br />(INCHES) <br />(36 KSD <br />(E` 0XX) <br />ASD <br />LRF® <br />a, 10 <br />2 <br />5 1/2 <br />5/16 <br />1/4 <br />20.4 <br />30.6 <br />12,14 <br />3 <br />8 1/2 <br />5/16 <br />1/4 <br />31.0 <br />4-1.1 <br />16 <br />4 <br />11 1/2 <br />5/16 <br />1/4 <br />42.4 <br />63,6 <br />18 <br />5 <br />141/2 <br />5/16 <br />1/4 <br />53.0 <br />_19.5 <br />21 <br />6 <br />li 1/2 <br />5/16 <br />1/4 <br />63.6 <br />95.4 <br />24 <br />7 <br />20 1/2 <br />5/16 <br />1/4 <br />-12.4 <br />111,0 <br />2-1 <br />S <br />231/2 <br />5/16 <br />1/4 <br />04.1 <br />127.0 <br />30 <br />9 <br />26 1/2 <br />5/16 <br />1/4 <br />94.8 <br />142.0 <br />1 <br />1/2'I <br />NOTES: <br />N <br />1. FOR BEAMS NOT SHOWN HERE IN, THE <br />SEE SCH <br />FABRICATOR SHALL DESIGN THE SHEAR <br />- <br />FOR NUMBER <br />CONNECTION BASED ON THE REACTION <br />i <br />I <br />OF BOLTS <br />SHOWN ON THE PLAN. <br />_ <br />I I <br />(3" OC) <br />2 PROVIDE HORIZ SLOTS IN SHEAR PLATE. <br />3. BEAMS SHALL BE 50 K51. <br />SEE SCH <br />4, PROVIDE HARDENED WASHER OVER <br />SLOTTED HOLES. <br />S�-4 <br />fi�L�4T <br />D T,4 f L <br />�4fi� <br />5. BOLTS SHALL BE INSTALLED "SNUG -TIGHT". <br />ow <br />0 <br />v <br />vv <br />K`Y� SECTION @ EXTERIOR � DETAIL -TIE COLUMN TIE COLUMN TYPES SECTION @ STEEL BM CONN- ATYPICAL BEAM TO HSS COL CONNECTION - <br />\CV HSS COL FTG Ilcv <br />COLUMN8 L�A�E PLATE SCk9EDULE 41147 <br />�R �� � �. . <br />EASE <br />PLATE <br />SIZE <br />ANCHOR <br />ROD <br />( <br />(INCHES) <br />(INCHES) <br />- - <br />MARK <br />SIZE <br />COMMENTS <br />A <br />E <br />T <br />E <br />(NOTE 2) <br />fQ <br />C1 <br />HSS 4x4x3/16 <br />10 <br />10 <br />3/4 <br />3/4 <br />10 <br />C2 <br />HSS 5x5x3/16 <br />11 <br />11 <br />3/4 <br />3/4 <br />10 <br />2d <br />26 N <br />G3 <br />HSS OxOx5/16 <br />14 <br />14 <br />3/4 <br />3/4 <br />10 <br />II All <br />NOTES: <br />1. ANCHOR RODS SHALL BE ASTM FI554 (GRADE 36) L1N0, <br />THREADED EACH END WITH NUT AT BOTTOM, TACK -WELDED <br />SECURE. PLATE WASHER AT BOTTOM NUT IS NOT REQ'D. <br />CONFORM TO CHART AT RIGHT FOR EMBEDMENT UNLESS <br />NOTED OTHERWISE IN SCHEDULE ABOVE,. <br />2. MAX EMBEDMENT "E" = (FTG THICKNESS) - 5". <br />3. PLATE WASHERS SHALL HAVE HOLE WITH DIAMETER <br />II <br />ROD <br />MIN <br />MIN <br />MATERIAL <br />EMBEDDED <br />EMBEDDED <br />LENGTH <br />EDGE <br />(NOTE 1) <br />"E" <br />DISTANCE <br />ASTt-1 F1554 <br />12d <br />5d > 4" <br />(GRADE 3(o) <br />BASE PLATE DETAIL <br />NOT TO SCALE <br />"d" (ROD DIA) <br />Q PLATE WASHERS <br />EQUAL TO ROD DIAMETER + 1/16 . CIRCULAR OR SQUARE <br />WASHERS ARE ACCEPTABLE. <br />4. IT SHALL BE ACCEPTABLE TO PROVIDE A HEAVY HEX HEAD BOLT <br />O <br />�D0 z <br />Q Ul(Y <br />(SEE SGH FOR SIZE) <br />T/ CONC <br />z a <br />a c) O ° ° <br />(a z a ° ° <br />IN LIEU OF THE THREADED ROD WITH HEAVY HEX NUT AT BOTTOM. <br />,� <br />(3) HEX NUTS <br />a PER ROD <br />a a � HEAVY HEX NUT, TYP <br />00 VERSIZE HOLES AND PLATE WASHERMO FOR BASE PLATE$ <br />ROD <br />D <br />DIAMETER <br />HOLE <br />DIAMETER <br />PLATE <br />WASHER <br />ROD <br />RD <br />DIAMETER <br />Oo <br />HLE <br />DIAMETER <br />PLATE <br />WASHER <br />N <br />o 4 o TACK <br />a OR PEEN <br />3/4" <br />1 5/16" <br />1/4"x2 <br />1 1/2" <br />2 5/16" <br />1/2"x3 1/2" <br />Z a <br />-1/8" <br />1 9/16" <br />5/16"x2 1/2'' <br />1 3/4" <br />2 3/4" <br />5/8"x4" <br />U <br />FACE OF WALL, TOOLED JOINT SHALL BE Z <br />COL OR <br />MADE WITH A "DEEP AND <br />TY <br />1/2" PRE -MOLDED THIN GROOVER" B <br />GOLDBLATT (PART W <br />EXP JOINT FILLER <br />#843890621 U OR EQUAL Z <br />4- <br />"&OFF -CUT" &AWCUT <br />JOINT 1/0"xl" DEEP 1 1/2" <br />d:-� TOOLED JOINT (To <br />ry <br />EXPANSION JOINT (NOTE: AT EXTERIOR LOCATIONS ONLY) <br />NOTES: <br />1. CUT SLAB AS SOON AS AGGREGATE DOES Q <br />NOT DISLODGE AND BEFORE CONCRETE U w <br />Z.g ° Z <br />0 STARTS TO COOL. WAITING PERIOD WILL Q o_o <br />U _\_r,\d /\/ Q Z TYPICALLY VARY FROM 1 HOUR IN HOT. DISCONTINUE J co Z <br />w 0 Z / `°a u z WEATHER TO 4 HOURS IN COLD WEATHER. REINF AT JOINT w U <br />❑ <br />. _aq . � � 1 L�tl (L 2. PLACE REINFORCING 1 1/2" CLEAR. lx2 KEY U_ Q <br />A� ^ <br />\� 3. HAND -TOOL JOINT TO FACE OF WALL � <br />- Q Lu <br />SEE FDN SCH WHERE SAWCUT DOES NOT REACH. �' ¢ a > <br />z O) <br />�M°. . <br />ui <br />SEE FOR REINF, ILL! CIO Q c i <br />NOTE , DN SG SAWCUT JOINT (SJ), <br />1. SIZE AND REINF VARIES. SEE <br />FOUNDATION SCHEDULE. CONSTRUCTION JOINT <br />I" 1 13/16" 3/8"x3" 2" 3 1/4" 3/4"x5" B/ CON( <br />11/4" 2 1/16" 1/2 ''x3 j 2 1/2" j 3 3/4" MONOLITHIC EDGE (ME) (CJ),�/S"x5 1/2" ANCHOR ROD DETAIL KEYED <br />NOT TO SCALE <br />A COLUMN AND BASE PLATE SCHEDULE 1'***B FOUNDATION SCHEDULE("C_�SLAB-ON-GRADE DETAILS (FOOT TRAFFIC <br />PCS301 \P2v <br />1 <br />PCS301 <br />J <br />MAISONRff WAIL BEAM SCHEDULE <br />UL E <br />NOMINAL <br />REINFORCO N0 <br />STIRRUPS <br />MARK <br />TYPE <br />SIZE <br />(W"xD") <br />COMMENTS <br />EOT <br />MID <br />TOP <br />SIZE <br />SPACING <br />551 <br />1 <br />Sx8 <br />-- <br />(2) #5 <br />-- <br />-- <br />-- <br />B52 <br />2 <br />8x16 <br />(2) #5 <br />-- <br />(2) #5 <br />-- <br />-- <br />553 <br />1 <br />12x& <br />-- <br />(2) #5 <br />-- <br />-- <br />-- <br />554 <br />2 <br />12x16 <br />(2) #5 <br />-- <br />(2) *5 <br />-- <br />-- <br />C51 <br />3 <br />EX24 <br />(2)'r1 <br />(2) #5 <br />(2) #5 <br />#3 <br />10" OC <br />T51 <br />4 <br />SX12 <br />(2) #5 <br />-- <br />(2) #5 <br />#3 <br />48" OC <br />T52 <br />4 <br />SX11 <br />(2) #5 <br />-- <br />(2) #5 <br />#3 <br />40" OC <br />d <br />;_.d • '. <br />id <br />f B <br />1 2 3 4 <br />BEAM TYPES <br />NOTES: <br />I. <br />MIN PB CAPACITY FOR THE INDICATED SPAN MUST BE VERIFIED BY THE <br />PRECAST MFR AND DOCUMENTATION PROVIDED IN THE SUBMITTALS. <br />2 <br />"BB" = BOND BEAM (COMPOSED OF KNOCK -OUT BLOCK) <br />STD AG[ LAP TOP BARS <br />VSO* <br />HOOK MID - SPAN <br />o , <br />°a. d <br />d .. <br />A <br />211 MAX <br />FOR BOTTOM BARS <br />(TYP) BOTTOM BARS <br />PROVIDE A GLASS <br />(oil <br />TENSION LAP CENTERED <br />OVER SUPPORT OR <br />MIN. " 4 <br />TERMINATE BARS <br />a ° <br />AS CONDITION <br />CLEAR <br />WARRANTS. <br />CLEAR <br />70, <br />SPAN <br />SPAN <br />NOTES: <br />1. PLACEMENT OF REINF TO BE PER ACI 318. <br />CONCRETE BEAM REINFORCING DIAGRAM <br />SCH-FTG(2000PSF) <br />FOOUNDA MN SCHEDULE <br />MARK <br />SIZE (L Y, W x D) <br />REINFORCING <br />REMARKS <br />F46 <br />4'-6" x 4'-6" x P-2" <br />(5) #5 EA WAY, BOT <br />PAD FOOTING <br />F50 <br />5'-0" x 5'-0" x 1'-2" <br />(5) #5 EA WAY, BOT <br />PAD FOOTING <br />F56 <br />5'-6" x 5'-6" x 1'-2" <br />(5) 05 EA WAY, BOT <br />PAD FOOTING <br />F0060 <br />0'-0" x 6'-O" x 1'-2" <br />(0) 05 SW, (6) 05 LW, BOT <br />PAD FOOTING <br />F11O8O <br />11'-O" x 8'-O" x 1'-2" <br />(11) #5 SW, (S) 05 LW, BOT <br />PAD FOOTING <br />F110g0 <br />j 11'-O" x 9'-O" x 1'-2" <br />01) #5 SW, (9) 05 LW, BOT <br />PAD FOOTING <br />F UNDD ATMN DD EM c' N NFOO RMATMN <br />ASSUMED NET ALLOWABLE SOIL BEARING PRESSURE, -- 2000 PSG <br />SUBSURFACE INVESTIGATION HAS NOT BEEN PERFORMED AND GEOTECHNICAL <br />ENGINEERING REPORT WAS NOT AVAILABLE FOR FOUNDATION DESIGN. PRIOR TO <br />CONSTRUCTION, THE OWNER SHALL RETAIN THE SERVICES OF A QUALIFIED <br />GEOTECHNICAL ENGINEER TO PERFORM 501L TEST BORINGS, PROVIDE <br />RECOMMENDATIONS FOR FOUNDATION DESIGN (INCLUD ING NET ALLOWABLE SOIL <br />BEARING PRESSURE), PROVIDE EARTHWORK COMPACTION GRITERIA, AND PERFORM <br />SOIL TESTING DURING CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR <br />PERFORMING ALL EARTHWORK OPERATIONS IN STRICT ACCORDANCE WITH THIS <br />REPORT, IF THE FOUNDATION RECOMMENDATIONS AND NET ALLOWABLE SOIL <br />BEARING GAPACITY DIFFER FROM THE ASSUMED VALUE, THEN MODIFIGATIONS TO THE <br />DRAWINGS WILL BE REQUIRED. SHOULD THIS OCCUR, THE CONTRACTOR SHALL STOP <br />CONSTRUCTION AND NOTIFY ARCHITECT/ENGINEER IMMEDIATELY. <br />J W <br />0 <br />m Z <br />3 <br />E v �/^' <br />o I� <br />Uj Z <br />N 0 <br />3 0 <br />E <br />w <br />U) <br />LD <br />0o Z <br />�0 J 0 <br />QJZ Q <br />❑Jo <br />X p <br />W J°Z5�v Z <br />- Q Y O W <br />�cf) 0 0 <br />LU <br />Z o LL <br />�YOwa = <br />N <br />a Cn <br />0 <br />z <br />0 <br />3 �Q <br />o <br />o <br />m <br />m <br />P <br />EE <br />m_ <br />23 <br />t <br />m <br />m <br />O <br />N <br />N <br />M 3 02 13 <br />\\ (7,� /7 - <br />I I� <br />�I I <br />I 4 <br />0 OI <br />I I <br />a a <br />NOTES: <br />NOTE: 1. a = 12 Ft. <br />ASDE 7-02 WALL DESIGN <br />WIND PRESSURES <br />AND SUCTIONS <br />FOR MEAN ROOF HEIGHT s 00 f1I <br />WIND PRESSURE <br />ARID SUCTION (PSF) <br />EFFECTIVE <br />(¢) VALUE DENOTES PRESSURE <br />WIND AREA <br />H VALUE DENOTES SUCTION <br />(SO FEET) <br />® <br />0 <br />10 <br />(+) 29.6 <br />(+) 29.6 <br />(-) 32.1 <br />(-) 39.6 <br />20 <br />(+) 20.3 <br />(+) 28.3 <br />C-) 30.8 <br />(-) 3-1.0 <br />50 <br />(+) 26.5 <br />(+) 26.5 <br />(-) 29.0 <br />(-) 33.5 <br />100 <br />(+) 25.2 <br />(+) 25.2 <br />(-) 27.7 <br />(-) 30.8 <br />LU <br />O; OHO` O�❑ ;O <br />L----, - <br />� 3 I 0 13 <br />PLAN VI EW <br />CHIP ROOF) <br />NOTES: <br />I .- to ri <br />'Ni`� �-�wr..i�r< '`"- I I y pf�' I F ' "'N"'2. A (Kd) OF 0.85 HAS BEEN USED IN THE <br />NOR EXFANSION BOLTS TO BE JSED, DEVELOPMENT OF THESE VALUES. THE 2. ID (Kd) OF 0.85 HAS BEEN USED (N THE <br />USE OF THESE VALUES SHALL ONLY BE DEVELOPMENT OF THESE VALUES. THE USE <br />APPLIED WHEN USED IN CONJUNCTION OF THESE VALUES SHALL ONLY BE <br />WITH LOAD COM INATIONS SPECIFIED IN APPLIED WHEN USED IN CONJUNCTION WITH <br />Z <br />0 <br />0 <br />m <br />m <br />E <br />0 <br />i <br />B <br />SECTIONS 2.3 & 2.4 OF A&CE 7-02. LOAD COMBINATIONS SPECIFIED IN F:407.645.3790 <br />SECTIONS 2.3 AND 2.4 OF ASCE 7-02. 1912 Boothe Circle- Suite 100 <br />Longwood, FL 32750 <br />bbma.com <br />\SCE • -02 <br />GROSS UPLIFT <br />DESIGN PRESSURES <br />FOR GABLE/HIP ROOFS WITH <br />ROOF SLOPE 7* - ®:� 270 (MRHI :s 501 <br />10 e ROOF SLOPED <br />GROSS UPLIFT <br />EFFECTIVE <br />PRESSURE (PSF) <br />WIND AREA <br />(SG FEET) <br />❑ <br />O <br />O <br />10 <br />(-) 27.1 <br />(-) 17.l <br />(-) 1-1.1 <br />20 <br />(-) 26.3 <br />(-) 15.6 <br />(-) 15.6 <br />50 <br />(-) 25.3 <br />(-) 13.6 <br />(-) 13.6 <br />100 <br />(-) 24.6 <br />(-) 12.0 <br />( 17J <br />LATERAL DESIGN ORI RIA <br />WIND VELOCITY: 11 <br />IMPORTANCE FACTOR: 1. <br />EXPOSURE CATEGORY: C <br />INTERNAL PRESSURE <br />5T4, ALEMNGINEERCOEFFIGIENT: <br />(ELF&FID) <br />0 <br />0 <br />0 <br />Ch <br />E <br />U) <br />x <br />Z <br />a <br />CN <br />w <br />J <br />W <br />IX <br />O <br />I. <br />Z <br />rn <br />o <br />� <br />a <br />N <br />ILL!I- <br />~ <br />m <br />O <br />W <br />Bora Erbilen P.E. #55996 <br />SHALL BE THE SAME A& CORRESPONDING; ENGINEER HEREBY EXPRESSLY RESERVES HIS <br />WALL ZONES 4 5. COMMON LAW COPYRIGHT AND OTHER PROPERTY <br />RIGHTS IN THESE PLANS. THIS DESIGN AND P 1 <br />DMASONRYDRAWINGS ARE NOT TO BE REPRODUCED CHANGED, A <br />OR COPIED IN ANY FORM OR MANNER WHATSOEVER <br />J( O <br />WITHOUT FIRST OBTAINING THE EXPRESSED WRITTEN <br />PERMISSION AND CONSENT OF "BURTON BRASWELL <br />MIDDLEBROOKS ASSOCIATES". NOR ARE THEY TO BE <br />1 ASSIGNED TO ANY PARTY WITHOUT FIRST OBTAINING <br />SAID WRITTEN PERMISSION AND CONSENT. <br />File=F: \2007\07122\07122-TECH\07122_SDWGS\07122_Sdwgs\PUBLIX\07122_PCS301.dwg Tab=PCS301 Date/Time= Apr 17, 2008 - 10: 43am Plot by jbrower <br />