Laserfiche WebLink
PER NFPA LIFE SAFETY CODE, 2004, FLORIDA FIRE PREVENTION CODE, 2004 AND FLORIDA BUILDING CODE, 2004 <br />TOTAL INCHES OF EGRESS CAPACITY REQUIRED EQUALS 213; 321 INCHES ARE PROVIDED <br />THESE PLANS COMPLY WITH 2O04 FLORIDA BUILDING CODE <br />EXIT REQUIREMENTS - F13C/IBC/NFPA-101 <br />OCCUPANCY BY USE AREA <br />REQD WIDTH <br />PROVIDED EXIT WIDTH <br />USE <br />AREA <br />SF/OCC <br />OCPNTS <br />RND UP <br />SUBTOT <br />TOTAL <br />IN/ OCC <br />EXIT <br />INCHES <br />DOOR <br />NUMBER <br />INCHES <br />TOTALS <br />GROUND FLOOR <br />1 <br />I <br />I <br />I <br />� <br />SALES <br />3%750 <br />30 <br />1,325.00 <br />1,325 <br />025 <br />0.20 <br />265 <br />1 <br />129 <br />OFFIC/PHARM/FOOD PRP <br />3,570 <br />30 <br />119.00 <br />119 <br />3 <br />129 <br />410 <br />30 <br />13.67 <br />14 <br />9 <br />33 <br />682 <br />30 <br />22.73 <br />23 <br />21 <br />45 <br />1,137 <br />30 <br />37.90 <br />38 <br />26 <br />33 <br />006 <br />30 <br />63.53 <br />64 <br />258 <br />0.20 <br />51.6 <br />SHIPPINGdSTORACE <br />55822 <br />30 <br />194.07 <br />195 <br />195 <br />0.20 <br />39 <br />588 <br />30 <br />19.60 <br />20 <br />20 <br />0.20 <br />4 <br />53,865 <br />1 <br />1 1979 <br />00.20 <br />359.61 <br />1 <br />1 <br />369 <br />�I <br />0 <br />21 <br />4511 <br />- II <br />' E n <br />T-� -7 <br />I <br />- - - - - - - - - - - - - - - - - - - - - - - - <br />53,865 sq ft <br />-------- <br />I - <br />o---------- - 2 Q il---®------ <br />---129-"- �I----- ------ 129" <br />II II <br />II II <br />II II <br />fl 0 <br />129" 129" <br />DOORS 1, 2, 3, AND 4= <br />AUTOMATIC DOORS HAVE BREAK -OPEN CAPABILITY <br />PROVIDING 129" OF EXIT WIDTH WITH ALL 4 PANELS <br />BROKEN OPEN <br />r- <br />i <br />77VCD <br />3311 <br />p <br />u <br />II <br />n <br />I <br />of <br />inc. <br />CODE ANALYSIS <br />BUILDING CODE ANALYSIS AND FIRE RATED COMPONENT STANDARDS <br />FLORIDA BLDG. CODE <br />CONSTRUCTION TYPE: <br />SPRINKLED: <br />OCCUPANCY <br />ALLOWABLE AREA: <br />PROTECTION: <br />EXTERIOR BEARING WALL: <br />ELECTRICAL EQUIPMENT ROOM: <br />COLUMNS: <br />BEAM, GIRDER, TRUSS: <br />ROOF/CEILING: <br />ROOF MEMBRANE: <br />SPACE ABOVE CEILING: <br />TYPE II - B (UNPROTECTED) <br />THROUGHOUT <br />M (MERCANTILE) <br />* UNLIMITED WITH 60'-0" BREAK <br />PER TABLE 601 <br />NON-COMBUSTIBLE <br />NON-COMBUSTIBLE <br />NON-COMBUSTIBLE <br />NON-COMBUSTIBLE <br />NON-COMBUSTIBLE <br />NON-COMBUSTIBLE <br />NO DRAFT STOPS REQUIRED (717.4.3) <br />INTERIOR FINISH: CLASS C (PER TABLE 803.5.); <br />CLASS AOR B WALLS AND CEILINGS (NFPA 1©1, 6-5, "AUTOMATIC SPRINKLERS") <br />" WHERE PERIMETER OPEN SPACE IS LESS THAN 60'-0", BUT NOT LESS THAN 40'-00, <br />THE EXTERIOR WALLS FACING THE REDUCED OPEN SPACE SHALL BE <br />3 HOUR OR MORE CONSTRUCTION. (507.4) <br />PLUMBING FIXTURES <br />FLORIDA PLUMBING CODE <br />SEE OCCUPANCY CALCULATIONS IN EXIT REQUIREMENTS CHART <br />GROUND FLOOR: <br />MEN = 899 <br />WOMEN = 899 <br />URNL <br />URNL <br />WC <br />WC <br />LAV <br />LAV <br />D.F. <br />D.F <br />FIXTURE <br />REQ'D <br />PROV <br />REQ'D <br />PROV <br />REQ'D <br />PROV <br />REQ'D <br />PROV <br />in <br />MEN <br />1 <br />2 <br />2 <br />1 <br />3 <br />2 <br />2 <br />WOMEN <br />3 <br />3 <br />1 <br />3 <br />FAMILY <br />1 <br />1 <br />GENERAL NOTES <br />1. ALL HOLES THAT ARE TO BE CUT IN THE ROOF OR <br />PATCHES TO BE MADE ARE TO BE DONE ONLY BY <br />THE ROOFING CONTRACTOR. <br />2. WHERE ALL COOLERS AND FREEZERS ARE AGAINST A <br />WALL THERE IS MINIMUM 2" SPACE BETWEEN THE <br />WALL AND COOLER OR FREEZER. THIS SPACE IS TO <br />BE CLOSED UP WITH BREAK METAL. (SEE DETAIL <br />2 ON SHEET A-18). ALSO WHERE COOLERS ARE <br />AGAINST COOLERS, PROVIDE AN ALUMINUM (.032GA) <br />CLOSER STRIP. <br />3. BASE AS SCHEDULED FOR SALES AREA IS NOT <br />REQUIRED BEHIND CASES AND SHELVING. EXTEND <br />BASE BEHIND ENDS OF CASES AND SHELVING <br />TO SAME EXTENT AS WALL FINISH. SEE FLOOR PLAN <br />AND INTERIOR ELEVATIONS. <br />4. ALL STUD WALLS ADJACENT TO COOLER OR FREEZER <br />WALLS SHALL BE COVERED WITH "MR" BOARD TO TOP <br />OF COOLER OR FREEZER. <br />5. CENTER 2x6 WOOD BLOCKING AT 3'-5" A.F.F. <br />FOR ALL SINKS WITH BACKSPLASHES. <br />6. CEILING SYSTEMS: INSTALL STENCILED PANELS <br />FOR PLUMBER'S SHUT-OFF VALVES, MOUNT PANELS <br />IN CEILING AS SHOWN ON DTL. 9/P-6. SEE <br />SHEETS A-3 AND P-1 FOR LOCATIONS. <br />DRAWING INDEX <br />T 1 TITLE SHEET, INDEX <br />PM-1 PROJECT MANUAL <br />PM-2 PROJECT MANUAL <br />PM-3 PROJECT MANUAL <br />PM-4 PROJECT MANUAL <br />PM-5 PROJECT MANUAL <br />PM-6 PROJECT MANUAL <br />PM-7 PROJECT MANUAL <br />PM-8 PROJECT MANUAL <br />PM-9 PROJECT MANUAL <br />LS-1 LIFE SAFETY PLAN <br />EQ-1 EQUIPMENT PLAN <br />A 1 FLOOR PLAN <br />A 2 SCHEDULES AND DETAILS <br />A 3 REFLECTED CEILING PLAN <br />A4 GRID / SOFFIT / WALL PLAN <br />A 5 ROOF PLAN <br />A 6 BUILDING SECTIONS <br />A 7 EXTERIOR ELEVATIONS <br />A 8 INTERIOR TILE ELEVATIONS <br />A 9 INTERIOR TILE ELEVATIONS <br />A 10 INTERIOR TILE ELEVATIONS <br />A 11 ENLARGED RESTROOM PLANS AND ELEVATIONS <br />A 12 INTERIOR ELEVATIONS <br />A 13 INTERIOR ELEVATIONS <br />A 14 WALL SECTIONS <br />A 15 WALL SECTIONS <br />A 16 WALL SECTIONS <br />A 17 PHARMACY SECTIONS AND DETAILS <br />A 18 SECTIONS AND DETAILS <br />ADA-1 ADA COMPLIANT -STANDARD DETAILS <br />ADA-2 ADA COMPLIANT -STANDARD DETAILS <br />R D-1 ROOF DETAILS <br />RD-2 ROOF DETAILS <br />UL-1 UL DESIGNS <br />S-1 FOUNDATION PLAN <br />S-2 SLAB PLAN <br />S-3 INTERMEDIATE PLAN <br />S-4 ROOF FRAMING PLAN <br />S-5 SECTIONS AND DETAILS <br />S-6 SECTIONS AND DETAILS <br />S-7 SCHEDULES AND DETAILS <br />S-8 EXTERIOR SECTIONS AND DETAILS <br />S-9 GENERATOR PADS AND DETAILS <br />P-1 WATER AND GAS PLUMBING PLAN <br />P-2 WATER AND GAS PLUMBING ISOMETRIC <br />P-3 SANITARY WASTE PLUMBING PLAN <br />P-4 SANITARY WASTE PLUMBING ISOMETRIC <br />P-5 PLUMBING SCHEDULES AND DETAILS <br />P-6 PLUMBING DETAILS <br />P-7 FLOOR DRAIN DIMENSION PLAN <br />FP-1 FIRE PROTECTION PLAN - UPPER LEVEL <br />FP-2 FIRE PROTECTION PLAN - LOWER LEVEL <br />FP-3 FIRE PROTECTION DETAILS AND NOTES <br />FP-,4 FIRE PROTECTION SECTIONS <br />M-1 HVAC FLOOR PLAN <br />M-2 HVAC DETAILS <br />M-3 HVAC SCHEDULES AND DETAILS <br />M-4 HVAC SECTIONS <br />M-5 HVAC HOOD ELEVATIONS <br />APPROVED <br />y k1re Mar'shall of Z,,-,phv I" <br />wig pl sj <br />�EVAITJ16 r(1 , 1, � L <br />il. L ]:jnc <br />t <br />t 0, CTr� U �r <br />r <br />E-1 ELECTRICAL LIGHTING PLAN -� <br />E-2 ELECTRICAL SECONDARY LIGHTING PLAN -_..._ <br />E-3 ELECTRICAL POWER PLAN <br />E-4 ELECTRICAL REFRIGERATION PLAN <br />E-5 ELECTRICAL ROOF PLAN <br />E-6 ELECTRICAL COMMUNICATION PLAN <br />E-7 ELECTRICAL FIRE/BURGLAR ALARM PLAN <br />E-8 ELECTRICAL EMS PLAN <br />E-9 ELECTRICAL RISER DIAGRAM <br />E-10 ELECTRICAL DETAILS <br />E-1 1 FIXTURE AND SYMBOL SCHEDULES AND ENLARGED AREAS <br />E-12 ELECTRICAL DEVICE ELEVATIONS <br />E-13 ELECTRICAL DEVICE ELEVATIONS <br />E-14 EMS DETAILS <br />E-15 LIGHTING DIMENSIONS <br />E-16 PANEL SCHEDULES <br />E-17 PANEL SCHEDULES <br />R-1 REFRIGERATION FLOOR PLAN <br />R-2 REFRIGERATION SCHEDULES AND SPECIFICATIONS <br />R-3 REFRIGERATION DETAILS <br />Publi*x. <br />SUPER MARKETS <br />CORPORATE OFFICES, FACILITIES DESIGN <br />BOX 407, LAKELAND, FL 33802 <br />(863) 680-5295 <br />PHYSICAL ADDRESS: <br />3300 PUBLIX CORPORATE PARKWAY, <br />LAKELAND, FL 33811-3311 <br />PUBLIX FACILITIES <br />DESIGN DEPARTMENT <br />DAVID TAULBEE, AIA <br />ARCHITECT - FL. REG. 91318 <br />DAVID RUBIN, AIA <br />ARCHITECT -FL. REG.92557 <br />GA. REG.11881 <br />SC. REG, 7477 <br />AL, REG. 6234 <br />TN. REG- 103497 <br />JOHN W. KITCHENS, PE <br />CIVIL/STRUCTURAL - FL. REG. 45277 <br />GA. REG. 020251 <br />SC. REG.16340 <br />AL REG.20382 <br />TN. REG.101507 <br />PAUL C. HARMAN, PE <br />STRUCTURAL- FL. REG. 51959 <br />GA. REG. 27740 <br />SC. REG.21754 <br />AL. REG.24905 <br />TN. REG.107882 <br />JOHN J. CARAMALIS, PE <br />MECHANICAL - FL REG. 43889 <br />GA. REG. 021246 <br />SC. REG. 16521 <br />AL REG.20581 <br />TN.REG.108507 <br />ANTHONY CLEMENTI, PE <br />MECHANICAL - FL REG. 54781 <br />GA. REG.31882 <br />SC. REG. 25591 <br />AL REG. 28469 <br />TN. REG. 111382 <br />RAYMOND J. SIRIANNI, PE <br />ELECTRIC - FL REG. 54085 <br />GA. REG. 025636 <br />SC. REG. 19743 <br />AL REG.23065 <br />TN. REG.108038 <br />NORMAN MEIER, PE <br />ELECTRICAL - FL. REG. 59422 <br />GA. REG. 31492 <br />SC.REG.25290 <br />AL. REG.28079 <br />�C COPYRIGHT 2000 <br />PUBLIX SUPER MARKETS, INC <br />THESE CONSTRUCTION DOCUMENTS ARE THE PROPERTY <br />OF PUBLIX SUPER MARKETS, INC. AND ARE NOT TO BE <br />COPIED OR REUSED FOR ANY SPECIFIC BUILDING WITHOUT <br />WRITTEN PERMISSION. THESE DRAWINGS SHALL NOT BE <br />DUPLICATED WITHOUT PRIOR WRITTEN PERMISSION OF <br />PUBLIX SUPER MARKETS, INC. <br />THE DESIGN INDICATED IN THESE CONSTRUCTION <br />DOCUMENTS DOES; TO THE BEST OF MY KNOWLEDGE, <br />INFORMATION, AND BELIEF; COMPLY WITH THE APPLICABLE <br />MINIMUM BUILDING CODES <br />J N11 <br />PUBLM <br />PLOT DATE: <br />10 JAN 08 <br />REVISION DATA: <br />#1245 (REPL. #0390) <br />ZEPHYR COMMONS <br />PRETTY POND RD. & HWY. 301 <br />ZEPHYRHILLS, PASCO CO., <br />FLORIDA <br />5A.� <br />Vi12707 <br />DRAWING TITLE: <br />TITLE SHEET, <br />INDEX <br />SCALE: NONE <br />0-JAN-2008 15:23 xmwc P:\1200-1299\1245\1245t01.dgn <br />INVIGORATE <br />