Laserfiche WebLink
TYPICAL <br />1 TOILET STALL PLANS <br />ADA-1 SCALE:1"=1'-O" (stdADA12) <br />10, OUTLET <br />TYPICAL (NON—ADA COMPLIANT) <br />FIXTURE MOUNTING. HEIGHTS <br />SCALE=[' = 1'-0" (5tdADA11) <br />CONT BEAD OF SEALANT <br />ANGLE BRACKETS,AT ENDS - MR1 <br />L 11/2' x 11/2' x Ts ", AS SHOWN. <br />WELD ALL JOINTS, GRIND <br />SMOOTH, DRILL FOR ALL <br />REQUIRED FASTENERS AND BOTTOM OF REFLECTING SURFACE <br />PAINT (BLACK ENAMEL), BOLT <br />TO WALL (2xl2) W/ THREE _ <br />ST. STL. LAG BOLTS <br />CONCEAL ANGLE ABOVE <br />BOTTOM OF APRON - - <br />Q0 <br />VERTICAL FRT WD 2x BLOCKING <br />AT METAL STUDS, AS REQUIRED <br />i <br />8" ol <br />2 x 12 FRT. WD. BLOCKING M <br />BETWEEN METAL STUDS, AT ALL, <br />BRACKET LOCATIONS. ALIGN ' <br />FACE OF 2 x 12 WITH FACE OF z <br />STUDS M <br />i N <br />SEE PLANS AND FINISH <br />SCHEDULE FOR ADDITION <br />WALL CONSTRUCTION AND <br />FINISH INFORMATION <br />NOTE: INSULATE THE HOT <br />WATER SUPPLY AND DRAIN LINES <br />AT ALL LAVATORIES w/ FOAM <br />RUBBER INSULATION. <br />ADA COMPLIANT <br />ri-oVANITY SECTION <br />�A-NO SCALE (stdADA09) <br />PTD ( ` PTD` I <br />I I <br />sb ; <br />I 1 <br />OPTIONAL <br />LOCATION <br />I <br />I <br />ALIGN <br />i <br />cq <br />¢ <br />¢ <br />z <br />INSULATEIALL EXPOSED <br />Z <br />x <br />�' PIPES ATILAVATORIES <br />z <br />Q <br />I, <br />j <br />¢� <br />¢ <br />W/ FOAM ,RUBBER <br />w <br />¢ <br />O� <br />.a.--� <br />CD <br />¢ <br />Q INSULATION TYP. <br />OQ <br />_j <br />U <br />o <br />¢ <br />LON <br />.. <br />Co— <br />E— <br />W <br />N <br />O <br />a <br />O� <br />�c, <br />N <br />CD <br />CD <br />N <br />(V <br />N <br />¢ FLOOR <br />CONDITION WITH MIRROR - <br />SIMILAR TO DETAIL THIS SHEET <br />ADA COMPLIANT <br />TYP. HANDSINK W/O <br />MIRROR <br />SCALEa" = 1'-0" (stdADA04) <br />22" x 25' INTEGRAL <br />CORIAN SINKTOP <br />AND BASIN -18 HI /Low E.W.C. <br />ARRANGEMENT. <br />SINGLE E.W.C. <br />MAY BE INSTALLED V-6V2' <br />-19 AT STANDARD OR <br />LOW HEIGHT, <br />ORIFICE <br />APRON CONTINUOUS <br />AROUND ALL SIDES <br />ORIFICE In <br />r� <br />Q <br />¢ 814 <br />LP o P-18 <br />N Ong <br />MAINTAIN ALL PIPES Lnco <br />WITHIN MINIMUM . oN <br />REQUIRED LAVATORY <br />CLEARANCE OUTLINES 6 <br />AS PER ADA FIG.31. , <br />m Q <br />¢ 3 <br />�wmm <br />• Bills me m <br />SCALE: 1" = 1'-0" (stdADA08) <br />J <br />i <br />I <br />I <br />TOILET ! / <br />PARTITION <br />ASSEMBLY 2" 2' <br />I PTD <br />SD I <br />0 M�21 <br />I <br />o ¢ CD <br />� x <br />a 0_ <br />Q <br />z <br />`1) PT4 I- <br />� <br />o � <br />LL ¢ LL <br />N � I 4 <br />INSULATE ALL EXPOSED <br />`PIPES AT ILAVATORIES w �- <br />_ lix N TW/ FOAM ,RUBBER z : 1 v. <br />¢ NINSULATION TYP. Q a`'' d <br />o M m ¢ w o C3 <br />Q J Q Q <br />FL <br />UJ cn <br />a CL 0 z d <br />x � LAVATORY <br />AND = <br />MIRROR CD <br />zt <br />FLOOR ¢ I ¢ ¢ c) aCD <br />I <br />( <br />i <br />ADA COMPLIANT <br />rT�FIXTURE MOUNTING HEIGHTS <br />SCALE:1"= 1'-0" <br />C <br />D <br />m <br />0 <br />0 <br />u <br />z <br />Ln <br />O <br />J <br />L1. <br />0 <br />F <br />� <br />x <br />I <br />v <br />¢ <br />P-3 <br />� <br />o <br />X <br />>Z <br />¢ <br />E <br />1'-2" MIN. <br />__j <br />(GEORGIA <br />3 <br />REQUIREMENT) <br />FLOOR <br />a <br />s <br />PROVIDE <br />30'x 48"CLEAR FLOOR SPACE <br />ADA <br />COMPLIANT <br />6 <br />URINAL <br />HEIGHT <br />ADA-1 <br />SCALE <br />1" = 1'-0' (stdADA05) <br />1 HI/LO -18 <br />UNIT <br />SINGLE <br />UNIT <br />I I <br />I I <br />I � <br />I � <br />I <br />I I <br />I <br />I i <br />I � <br />I � <br />1 30' x 48" <br />IADA CLEAR <br />I -(MINIMUM) <br />------ - - - - -- -I <br />(stdADA02) <br />FLOOR <br />WOOD BLOCKING AS TTD <br />REO'D TYP. AT ALL <br />GRAB BAR LOCATIONS. <br />BOTH GRAB BARS TO <br />BE AT SAME HEIGHT, <br />s° <br />R36 <br />I <br />R42 <br />z <br />2 � <br />Q <br />Co =[V <br />a - m �— - - - FVA <br />VALVE <br />i <br />_ <br />3 <br />N <br />X <br />x <br />= <br />- <br />N <br />¢ <br />,. <br />-' <br />^ <br />z <br />LIJ: <br />-N <br />q., <br />¢ <br />i <br />¢ <br />Q <br />o0 <br />Q <br />¢ <br />Qe�; <br />BACK BLOCKING <br />REQUIRED - SEE <br />DETAIL 13 ON THIS <br />SHEET <br />/ <br />� <br />I <br />BCS <br />I <br />U) <br />I <br />I <br />Wd <br />J <br />CD- <br />W <br />CD <br />L- <br />--------.- <br />I <br />J. <br />Z X <br />CD - <br />(o <br />Jm <br />_j�r <br />Z <br />CD <br />wo¢ <br />PROVIDE ADDITIONAL <br />STRAP AS AN OPENING <br />MECHANISM FOR A <br />CLOSED FIST OR FLAIL <br />Q <br />o HAND OPERATION. <br />2: <br />~ <br />3 <br />CO <br />O <br />ADA COMPLIANT <br />BABY CHANGING STATION HEIGHT <br />SCALE-.1' = 1'-0" (stdADA06) <br />(stdADAlegend) <br />ADA COMPLIANT <br />12 E.W.C. PLAN <br />ADA-1 SCALE: 1' = 1'-0' (stdADA15) <br />4'-G' MIN. <br />;Al <br />=N~ <br />.-. ¢ 3 <br />L <br />, <br />2:1— <br />- <br />m <br />O <br />p <br />~ <br />---- <br />I — <br />- ¢ <br />00 <br />Q <br />Q <br />WJC. <br />10" OUTLET <br />ADA COMPLIANT <br />12�FIXTURE MOUNTING HEIGHTS <br />SCALE: 1" = 1'-0' <br />MR1 <br />¢ <br />P-4 <br />in <br />'I <br />--- <br />¢ <br />m <br />as <br />2: <br />- „ <br />cn <br />1 <br />(n <br />! <br />N INSULATE ALL EXPOSED <br />> N <br />11 <br />o PIPES AT LAVATORIES <br />- <br />i <br />W <br />W/ FOAM RUBBER <br />U Li <br />w <br />i <br />a <br />o INSULATION TYP. <br />x <br />Lt_ <br />i <br />cn <br />Q <br />- <br />0- <br />ui <br />OPTIONAL COVER <br />ox <br />w <br />X <br />v <br />z <br />rl <br />6' <br />8' <br />MIN. <br />ol cn <br />MIN. <br />¢ <br />MAX. <br />Q <br />TOE CLR. <br />KNEE CLR. <br />N <br />a <br />17' MIN. <br />ADA COMPLIANT <br />LAVATORY SECTION <br />ADA-1 SCALE 1' = 1'-0" (5tdADA14) <br />NOTE: <br />AT OTHER AREAS PROVIDE AND INSTALL <br />Y8'FRT PLYWOOD OR 20 GAUGE STEEL <br />PLATE WELDED TO STUDS MIN. 12"IN HEIGHT <br />BY LENGTH AS REQUIRED. COORDINATE LOCATIONS <br />AND MOUNTING HEIGHTS AS PER DIMENSIONS ON <br />THIS SHEET. <br />FRT PLYWOOD BACKING, SET AT <br />STUD FACE,BOTTOM AT 30"AFF, TOILET ROOM WALL - SEE PLAN FOR <br />AND TOP AS REQUIRED FOR BABY TYPE AND CONSTRUCTION NOTES <br />CHANGING STATION. <br />2x FRT WD. BLOCKING ATTACHED TO <br />METAL STUDS, AS REQUIRED <br />BCS <br />BABY CHANGING STATION <br />BLOCKING LENGTH AS REQUIRED <br />TYPICAL BLOCKING <br />— PLAN DETAIL <br />(s tdADA03) <br />LOCATE HOOK <br />ON TOILET <br />PARTITION OR WALL. <br />LOCATION OF HOOK <br />MUST NOT CAUSE <br />OBSTRUCTION OR <br />HAZARD TO USERS. <br />TOILET <br />PARTITION <br />ASSEMBLY <br />IF; <br />F- <br />z <br />w <br />Ln <br />z <br />FLOOR <br />ADA COMPLIANT <br />rq-- COAT HOOK HEIGHT <br />ADA-1 NO SCALE (stdADA07) <br />TOILET ACCESSORY LEGEND: <br />(stdADAlegend) <br />RCS <br />BABY CHANGING STATION - <br />CH <br />COAT HOOK - B-233 CLOTHES HOOK.(BOBRICK) <br />FVA <br />FLUSH VALVE ASSEMBLY - SEE MECHANICAL SPECIFICATIONS <br />MR1 <br />MIRROR - 16' x 36' w/ S.S. FRAME,- SEE <br />ARCHITECTURAL SPECIFICATIONS <br />MIRROR - 18"x 42'MOUNT ON INSIDE OF RESTROOM <br />MR2 <br />E) <br />DOOR OR WHERE INDICATED ON THE PLAN, SEE <br />ARCHITECTURAL SPECIFICATIONS <br />P-1 <br />WATER CLOSET - SEE PLUMBING SCHEDULE <br />P-2 <br />WATER CLOSET - ADA COMPLIANT, SEE PLUMBING SCHEDULE <br />P-3 <br />URINAL - ADA COMPLIANT,SEE PLUMBING SCHEDULE <br />P-4 <br />LAVATORY - CORIAN MODEL 810 W/ INTEGRATED SINKTOP, GLACIER Wl I <br />P-5 <br />LAVATORY IN ADA COMPLIANT VANITY,SEE PLUMBING SCHEDULE <br />-1 <br />WATER HI/LO COOLER - ADA COMPLIANT, SEE PLUMBING SCHEDULE <br />-1 <br />WATER SINGLE COOLER - ADA COMPLIANT,SEE PLUMBING SCHEDULE <br />PTO <br />PAPER TOWEL DISPENSER - KIMBERLY CLARK MODEL 09302 <br />R36 <br />GRAB BAR - 36'S.S„ SEE ARCHITECTURAL SPECIFICATIONS <br />NOTE: <br />R42 <br />GRAB BAR - 42' S.S., SEE ARCHITECTURAL SPECIFICATIONS <br />DIMENSIONS INDICATED WITHIN PARENTHESES ARE FOR <br />SCD <br />SEAT COVER DISPENSER - KIMBERLY CLARK MODEL 09526 <br />INFORMATION USE ONLY.IT PROVIDES ADA REQUIREMENTS <br />AND A RANGE ALLOWED BY CONSENT DECREE FOR <br />. SO <br />POST-ADAAG ALLOWANCES WHICH ARE ONLY TO BE USED <br />SOAP DISPENSER - KIMBERLY CLARK MODEL 91011 <br />FOR EXISTING FACILITIES. <br />SANITARY NAPKIN RECEPTACLE - RUBBERMAID MODEL 6140-00, <br />ALL NEW CONSTRUCTION ARE TO BE INSTALLED TO THE <br />SNR <br />IN WOMEN'S OR UNISEX RESTROOMS ONLY. <br />DIMENSIONS THAT ARE NOT IN PARENTHESES. SOME OF THESE <br />DIMENSIONS HAVE TOLERANCES BUILT INTO THEM THAT ARE <br />TTD <br />TOILET TISSUE DISPENSER - KIMBERLY CLARK MODEL 09566 <br />MORE STRINGENT THAN WHAT IS REQUIRED BY ADA. <br />THESE TOLERANCES HAVE BEEN ADOPTED BY PUBLIX FOR <br />TR <br />TRASH RECEPTACLE (RUBBERMAID- PRODUCT N0.2673 <br />BETTER CUSTOMER CONVENIENCE AND TO ALLOW FOR <br />SLIM JIM TOP )- PUBLIX <br />CONSTRUCTION TOLERANCES. <br />ELECTRIC HAND DRYER - ASI MODEL 0160 STD. WHITE <br />EHD <br />(ALTERNATE FOR REMODELS ONLY) <br />NEW VERSION NO. <br />DENOTES <br />ITEMS THAT WILL BE FURNISHED AND INSTALLED BY PUBLIX <br />NO SCALE (stdADAIO) VERSION NO. 092603 <br />(Sept. 26, 2003) <br />PLEASE REPLACE PREVIOUS VERSION 080703 <br />P u b ll'o xe <br />SUPER MARKETS <br />CORPORATE OFFICES, FACILITIES DESIGN <br />BOX 407, LAKELAND, FL 33802 <br />(863) 680-5295 <br />PHYSICAL ADDRESS: <br />3300 PUBLIX CORPORATE PARKWAY, <br />LAKELAND, FL 3381 1-3311 <br />PUBLIX FACILITIES <br />DESIGN DEPARTMENT <br />DAVID TAULBEE, AIA <br />ARCHITECT - FL. REG. 91318 <br />DAVID RUBIN, AIA <br />ARCHITECT -FL. REG.92557 <br />GA REG.]1881 <br />SC. REG. 7477 <br />AL. REG, 623A <br />TN. REG. 103A97 <br />JOHN W. KITCHENS, PE <br />CIVIL/STRUCTURAL-FL. REG. A5277 <br />GA REG. 020251 <br />SC. REG. 16340 <br />AL. REG. 20382 <br />TN. REG. 101507 <br />PAUL C. HARMAN, PE <br />STRUCTURAL - FL. REG. 51959 <br />GA, REG. 277,40 <br />SC. REG.21754 <br />Al. REG. 2A905 <br />TN. REG.107882 <br />JOHN J. CARAMALIS, PE <br />MECHANICAL - FL REG. A3889 <br />GA. REG.021246 <br />SC. REG. 16521 <br />AL REG.20581 <br />TN. REG.108507 <br />ANTHONY CLEMENTI, PE <br />MECHANICAL. FL REG.54781 <br />GA REG.31882 <br />SC. REG. 25591 <br />AL REG. 28469 <br />TN. REG.111382 <br />RAYMOND J. SIRIANNI, PE <br />ELECTRICAL- FL. REG. 54085 <br />GA. REG. 025636 <br />SC. REG. 197A3 <br />AL REG.23065 <br />TN. REG.108038 <br />NORMAN MEIER, PE <br />ELECTRICAL - FL. REG. 59422 <br />GA REG.31492 <br />SC. REG.25290 <br />AL. REG.28079 <br />© COPYRIGHT 2008 <br />PUBLIX SUPER MARKETS, INC. <br />THESE CONSTRUCTION DOCUMENTS ARE THE PROPERTY <br />OF PUBLIX SUPER MARKETS, INC. AND ARE NOT TO BE <br />COPIED OR REUSED FOR ANY SPECIFIC BUILDING WITHOUT <br />WRITTEN PERMISSION. THESE DRAWINGS SHALL NOT BE <br />DUPLICATED WITHOUT PRIOR WRITTEN PERMISSION OF <br />PUBLIX SUPER MARKETS, INC_ <br />THE DESIGN INDICATED IN THESE CONSTRUCTION <br />DOCUMENTS DOES; TO THE BEST OF MY KNOWLEDGE, <br />INFORMATION, AND BELIEF; COMPLY WITH THE APPLICABLE <br />MINIMUM BUILDING CODES <br />PUBLIX <br />PLOT DATE: <br />10 JAN 08 <br />REVISION DATA: <br />rE #12A5 (REPL. #0390) <br />ZEPHYR COMMONS <br />PRETTY POND RD. & HWY. 301 <br />ZEPHYRHILLS, PASCO CO., <br />FLORIDA <br />54*4 <br />V112707 <br />DRAWING TITLE: <br />ADA COMPLIANT - <br />STANDARD DETAILS <br />SCALE: AS NOTED <br />ADA 1 <br />JAN-2008 12.26 xm c P:\1200-1299\1245\1245eda01.dgn <br />of 2 <br />