ELECTRICAL LEGEND <br />❑O �O <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />SP @= <br />SURGE PROTECTION DUPLEX RECEPTACLE, 20A, 125V <br />PROVIDE WITH EMERGENCY BALLAST <br />HUBBELL CATAO HBL5360SA, NEMA 5-20R <br />® <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />0= <br />DUPLEX RECEPTACLE <br />ABOVE COUNTER OR AS NOTED, NEMA 5-20R <br />® <br />FLUORESCENT TROFFER, TYPE AS NOTED <br />QUAD RECEPTACLE <br />PROVIDE WITH EMERGENCY BALLAST <br />18" AFF OR AS NOTED, NEMA 5-20R <br />O <br />RECESSED CAN FIXTURE, TYPE AS NOTED <br />IG <br />DUPLEX RECEPTACLE <br />18" AFF OR AS NOTED, NEMA 5-20R <br />O <br />RECESSED CAN FIXTURE, TYPE AS NOTED <br />SPECIAL PURPOSE RECEPTACLE <br />PROVIDE WITH EMERGENCY BALLAST <br />18" AFF OR AS NOTED, SEE SCHEDULE <br />F-<>--i <br />FLUORESCENT STRIP FIXTURE <br />Fo/ JO <br />WALL / CEILING MOUNTED JUNCTION BOX <br />60/3/1 <br />UNFUSED DISCONNECT SWITCH <br />WALL MOUNTED FIXTURE, TYPE AS NOTED <br />❑i <br />RATING/POLES/NEMA RATING <br />60/3/3R/40 <br />FUSED DISCONNECT SWITCH <br />PENDANT FIXTURE, TYPE AS NOTED <br />RATING/POLES/NEMA RATING/FUSE SIZE <br />PENDANT FIXTURE, TYPE AS NOTED <br />MOTOR <br />PROVIDE WITH EMERGENCY BALLAST <br />•j••�•;• <br />TRACK LIGHT FIXTURE, TYPE AS NOTED <br />�II <br />GROUND <br />EMERGENCY LIGHT <br />0 <br />TELEPHONE OUTLET, PROVIDE 4- BOX <br />SINGLE GANG PLASTER RING, 1" C STUBBED 6" ABOVE CEILING <br />TELEPHONE OUTLET, PROVIDE 4" BOX <br />EXIT/EMERGENCY LIGHT COMBINATION <br />-� <br />HALF SHADED- INDICATES SINGLE JACK, FULL SHADED INDICATES <br />TWO JACKS. NETWORK WIRING SYSTEM: <br />® <br />CEILING MOUNTED EXIT SIGN <br />CAT 5E 110, RJ45 JACK WIRED TO SPEC 568B MODULAR JACK <br />PROVIDE ONE JACK AND ONE POSITION IVORY FACEPLATE AT <br />WALL MOUNTED EXIT SIGN <br />SINGLE JACK LOCATIONS AND TWO AT DOUBLE LOCATIONS. <br />CONTACT PHIL BENTON, 678-966-3335 FOR INFO. <br />DOUBLE BOX, AS DESCRIBED ABOVE EXCEPT CONNECT 2 LINES <br />SINGLE POLE SWITCH, 44" AFF <br />- <br />DIRECTLY FROM PUNCH BLOCK (D-MARK) TO DOUBLE BOX IN <br />MANAGEROFFICE <br />TWO SINGLE POLE SWITCHES GANGED TOGETHER <br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF <br />THREE SINGLE POLE SWITCHES GANGED TOGETHER <br />SINGLE BOX- MANAGER'S/FAX, DEDICATED ANALOG TELEPHONE <br />44" AFF <br />® <br />LINE WITH RINGMASTER, CAT 5E, RJ11 - NOT TO BE ROUTED <br />THROUGH TELEPHONE SYSTEM. TERMINATE AT PUNCH BLOCK <br />THREE WAY SWITCH, 44" AFF <br />(D-MARK) <br />TWO THREE WAY SWITCHES GANGED TOGETHER <br />SINGLE BOX- DSL/LSR DEDICATED ANALOG TELEPHONE LINE <br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF <br />0 <br />WITH RINGMASTER, CAT 5E, RJ11 - NOT TO BE ROUTED THRU <br />TELEPHONE SYSTEM, TERMINATE AT PUNCH BLOCK (D-MARK) <br />FOUR WAY SWITCH, 44" AFF <br />4 <br />WALL BOX DIMMER 1000W UNLESS NOTED DIFFERENTLY <br />all <br />SPEAKER STROBE <br />44" AFF <br />$WP <br />WEATHER PROOF SWITCH, 44" AFF <br />QN <br />HORN <br />$M <br />MOTOR RATED SWITCH, 44" AFF OR AS NOTED <br />IN <br />PULL STATION o <br />$OS <br />COMBINATION SWITCH AND OCCUPANCY SENSOR, 44" AFF <br />Q <br />FIRE ALARM STROBE, MIN 75 CANDELA <br />CEILING / WALL MOUNT <br />$T <br />DIGITAL TIMER SWITCH, 44" AFF <br />DUCT MOUNTED SMOKE DETECTOR <br />®X <br />CEILING MOUNTED OCCUPANCY SENSOR <br />OS <br />SMOKE DETECTOR <br />�X <br />WALL MOUNTED OCCUPANCY SENSOR, 44" AFF <br />OH <br />HEAT DETECTOR <br />T� <br />TIME CLOCK <br />TS <br />TAMPER SWITCH <br />®� <br />SINGLE DOME, CEILING AND WALL MOUNTED SECURITY <br />0FLOW <br />SWITCH <br />CAMERAS. FURNISHED AND INSTALLED BY OTHERS, <br />® <br />PHOTO CELL <br />a'�-� <br />RACEWAY CONCEALED IN WALL OR ABOVE CEILING <br />® <br />8" CONE SPEAKER IN CEILING <br />RACEWAY EXPOSED <br />EC TO PROVIDE BLACK SPEAKER <br />/0-\ <br />8" CONE SPEAKER IN WALL <br />��� <br />RACEWAY CONCEALED IN FLOOR SLAB, BELOW SLAB OR GRADE <br />EC TO PROVIDE BLACK SPEAKER <br />BELOW SLAB OR GRADE, OR UNDER RAISED ACCESS FLOOR <br />1 <br />VOLUME CONTROL <br />- 0 <br />DENOTES CONDUIT TURNING UP IN PLAN VIEW <br />PLYWOOD EQUIPMENT BACKBOARD <br />-------- 0 <br />DENOTES CONDUIT TURNING DOWN IN PLAN VIEW <br />4'X8' UNLESS NOTED OTHERWISE <br />CC <br />CLOSED CIRCUIT TELEVISION CAMERA <br />STUB UP <br />COAXIAL CABLE OUTLET <br />XXXX <br />SHORT CIRCUIT AVAILABLE CURRENT <br />(NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS AND ARE USED AS APPLICABLE TO THIS PROJECT) <br />ABBREVIATIONS <br />A, AMPS <br />AMPERES <br />FLA <br />FULL LOAD AMPERES <br />NO <br />NORMALLY OPEN, <br />A/C <br />AIR CONDITIONER <br />GND <br />GROUND <br />NUMBER <br />AC <br />ALTERNATING CURRENT <br />GALV <br />GALVANIZED <br />NTS <br />NOT TO SCALE <br />AF <br />AMPERE FRAME <br />GRS <br />GALVANIZED RIGID STEEL <br />PNL <br />PANELBOARD <br />AFF <br />ABOVE FINISHED FLOOR <br />GFCI <br />GROUND FAULT <br />PVC <br />POLYVINYL CHLORIDE <br />AFG <br />ABOVE FINISHED GRADE <br />CIRCUIT INTERRUPTER <br />RGS <br />RIGID GALVANIZED <br />AIC <br />AMPERE <br />GFI <br />GROUND FAULT INTERRUPTER <br />RMC <br />STEEL CONDUIT <br />RIGID METALLIC <br />INTERRUPTING CURRENT <br />AL <br />ALUMINUM <br />HD <br />HEAT DETECTOR <br />CONDUIT (GALVANIZED) <br />ANSI <br />AMERICAN NATIONAL <br />HP <br />HORSEPOWER <br />RMS <br />ROOT -MEAN -SQUARE <br />STANDARDS INSTITUTE <br />IMC <br />INTERMEDIATE METAL CONDUIT <br />RNC <br />RIGID NON-METALLIC <br />AWG <br />AMERICAN WIRE GAUGE <br />ISC <br />INTERRUPTING SHORT CIRCUIT <br />CONDUIT <br />BC <br />BARE COPPER <br />IG <br />ISOLATED GROUND <br />SCA <br />SHORT CIRCUIT <br />BKBD <br />BACKBOARD <br />INST <br />INSTANTANEOUS <br />AVAILABLE <br />JB <br />JUNCTION BOX <br />SWBD <br />SWITCHBOARD <br />C <br />CONDUIT <br />KAIC <br />KILO (THOUSAND) AMPERES <br />SWGR <br />SWITCHGEAR <br />CB <br />CIRCUIT BREAKER <br />INTERRUPTING CAPACITY <br />TBD <br />TO BE DETERMINED <br />CKT <br />CIRCUIT <br />KCMIL <br />KILO (THOUSAND) <br />TCP <br />TEMPERATURE CONTROL <br />CU <br />COPPER <br />CIRCULAR MILS <br />PANEL <br />DIST <br />DISTRIBUTION <br />KV <br />KILO (THOUSAND) VOLTS <br />TD <br />TIME DELAY <br />DIN <br />DOWN <br />KVA <br />KILO (THOUSAND) <br />TEL <br />TELEPHONE <br />DP <br />DISTRIBUTION PANEL <br />VOLT-AMPERES <br />TVSS <br />TRANSIENT VOLTAGE <br />DWG <br />DRAWING <br />KW <br />KILO (THOUSAND) WATTS <br />SURGE SUPPRESSION <br />EB <br />ENCASED BURIAL <br />KWH <br />KILO (THOUSAND) WATT-HOURS <br />TYP <br />TYPICAL <br />EC <br />EMPTY CONDUIT <br />LFMC <br />LIQUID -TIGHT FLEXIBLE <br />UG <br />UNDERGROUND <br />EEW <br />ENERGIZED ELECTRICAL WORK <br />METAL CONDUIT <br />EGC <br />EQUIPMENT GROUNDING <br />MCB <br />MAIN CIRCUIT BREAKER <br />UL <br />UNDERWRITER'S LABORATORIES <br />CONDUCTOR <br />MCM <br />THOUSAND CIRCULAR MILS <br />UON <br />UNLESS OTHERWISE <br />ELR <br />END -OF -LINE RESISTOR <br />MCCB <br />MOLDED CASE <br />UNDERGROUND PULLBOX <br />EWC <br />ELECTRIC WATER COOLER <br />MLO <br />MAIN LUGS ONLY <br />V <br />VOLTS <br /><E> <br />EXISTING <br />N <br />NEUTRAL <br />VA <br />VOLT-AMPERES <br /><ER> <br />EXISTING TO REMAIN <br />NEC <br />NATIONAL ELECTRICAL <br />VFD <br />VARIABLE <br /><EX> <br />EXISTING <br />CODE <br />FREQUENCY DRIVE <br />FA <br />FIRE ALARM <br />NESC <br />NATIONAL ELECTRICAL <br />WH <br />WATER HEATER <br />FAA <br />FIRE ALARM ANNUNCIATOR <br />SAFETY CODE <br />WP <br />WEATHERPROOF <br />ELECTRICAL SPECIFICATIONS <br />A. DEFINITIONS: <br />1. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR OPERATION. <br />2. "INSTALL": RECEIVE, MOUNT, AND CONNECT, COMPLETE AND READY FOR OPERATION. <br />3. "FURNISH": SUPPLY, DELIVER TO JOB SITE, PROTECT AND STORE. <br />B. WORK INCLUDED: PROVIDE ALL LABOR, TOOLS, MATERIAL, EXCAVATION, BACKFILL, CUTTING, PATCHING, <br />TESTING, ADJUSTING, AND TRADE COORDINATION REQUIRED FOR A COMPLETE AND FULLY <br />OPERATIONAL INSTALLATION, AS DESCRIBED ON THE DRAWINGS OR IN THE SPECIFICATIONS. <br />C. CODES, RULES, AND REGULATIONS: COMPLY WITH ALL CODES ENFORCED BY THE LOCAL INSPECTION <br />AUTHORITY, THE EDITION OF THE NATIONAL ELECTRICAL CODE BEING ENFORCED FOR THIS PROJECT <br />BY THE LOCAL INSPECTION AUTHORITY, ALL APPLICABLE LAWS AND ORDINANCE, NFPA FIRE CODES, <br />STANDARD BUILDING CODE. GIVE ALL NECESSARY NOTICES, OBTAIN ALL REQUIRED PERMITS, AND PAY <br />ALL INSPECTION AND OTHER FEES REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER THE WORK. <br />D. MATERIALS: ALL MATERIAL SHALL BE NEW, AND SHALL COMPLY WITH THE INDICATED STANDARDS. ALL <br />MATERIAL SHALL BE UL LABELED OR UL LISTED. ALL MATERIAL SHALL BE OF A SUITABLE TYPE AND <br />RATING FOR THE INTENDED USE, AND SHALL BE INSTALLED IN CONFORMANCE VVITH THE INSTRUCTIONS <br />AND RECOMMENDATIONS OF THE MANUFACTURER. <br />E. DRAWINGS <br />1. THE DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL OF THE REQUIRED DETAILS <br />OF THE WORK. ALL MATERIALS CUSTOMARILY CONSIDERED TO BE A PART OF THE ELECTRICAL <br />WORK AND REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION SHALL BE PROVIDED <br />WITHOUT ADDITIONAL COST TO THE OWNER. <br />2. THE CONTRACTOR SHALL REFER ALSO TO THE ARCHITECTURAL DRAWINGS AND TO THE <br />DRAWINGS OF ALL OTHER TRADES TO COORDINATE THE ELECTRICAL INSTALLATION. WHERE <br />ELECTRICAL EQUIPMENT IS SHOWN ON ARCHITECTURAL DRAWINGS OR DETAILS, THE EQUIPMENT <br />SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL DRAWINGS. <br />3. EQUIPMENT OF OTHER TRADES IS SHOWN SCHEMATICALLY ON THE ELECTRICAL DRAWINGS. THE <br />CONTRACTOR SHALL EXAMINE THE DRAWINGS OF THE TRADE PROVIDING THE EQUIPMENT <br />BEFORE ROUGHING IN THE CONNECTIONS FOR IT. THE CONTRACTOR SHALL CONNECT THE <br />EQUIPMENT WHERE ACTUALLY INSTALLED, INCLUDING WIRING THROUGH ANY LINE VOLTAGE <br />CONTROLLERS, WITHOUT ANY ADDITIONAL COST TO THE OWNER. <br />4. PRIOR TO ROUGHING IN CIRCUITS FOR EQUIPMENT FURNISHED BY OTHER TRADES, AND PRIOR <br />TO RELEASING FOR MANUFACTURE PANELBOARDS, STARTERS OR MOTOR CONTROL CENTERS <br />FEEDING SUCH EQUIPMENT, THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL <br />PROVISIONS BEING PLANNED WITH THE TRADE PROVIDING THE EQUIPMENT AND SUBMIT ANY <br />CONFLICTS IN WRITING TO THE ARCHITECT. <br />5. THE ARCHITECT MAY DIRECT THE RELOCATION OF ANY ELECTRICAL OUTLET, FIXTURE, OR OTHER <br />EQUIPMENT TO A LOCATION WITHIN 10 FEET OF THE LOCATION SHOWN ON THE DRAWINGS AT NO <br />ADDITIONAL COST TO THE OWNER PROVIDED SUCH RELOCATION IS DIRECTED PRIOR TO THE <br />INSTALLATION OF THE OUTLET, FIXTURE OR EQUIPMENT BEING RELOCATED. <br />D. SUBMITTAL DOCUMENTS: PRODUCT DATA AND SHOP DRAWINGS SHALL BE SUBMITTED IN SIX COPIES TO <br />THE ARCHITECT FOR REVIEW PRIOR TO THE RELEASE OF THE MATERIAL FOR MANUFACTURE. REVIEW <br />OF SUBMITTALS BY THE ARCHITECT WILL BE ONLY FOR GENERAL CONFORMANCE WITH THE DRAVINGS <br />AND SPECIFICATIONS. REVIEW WILL BE MADE ONLY OF INFORMATION CLEARLY AND SPECIFICALLY <br />INDICATED IN THE SUBMITTAL, AND DOES NOT IMPLY THE ACCEPTABILITY OF DETAILS WHICH ARE NOT <br />SO DESCRIBED IN THE SUBMITTAL. REVIEW OF THE SUBMITTAL DOCUMENTS BY THE ARCHITECT DOES <br />NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO COMPLY WITH ALL REQUIREMENTS OF THE <br />DRAWINGS AND SPECIFICATIONS. SUBMITTAL IS REQUIRED FOR PANELBOARDS AND LOADCENTERS, <br />LIGHT FIXTURES, WIRING DEVICES, FIRE ALARM DEVICES, AND SURFACE ALUMINUM RACEWAY. <br />G. AS -BUILT DRAWINGS: AS -BUILT DRAWINGS SHALL BE MAINTAINED AT THE JOBSITE, AND SHALL BE <br />AVAILABLE FOR REVIEW DURING CONSTRUCTION, AS -BUILT DRAWINGS SHALL BE KEPT CURRENT <br />DURING THE COURSE OF CONSTRUCTION OF THE WORK. SUBMIT AS -BUILT DRAWINGS TO THE <br />ARCHITECT AT THE COMPLETION OF THE PROJECT. <br />H. TESTING: TEST ALL PARTS OF THE WORK TO VERIFY COMPLIANCE WITH THE DRAWINGS AND <br />SPECIFICATIONS. VERIFY TIGHTNESS OF ALL MECHANICAL AND ELECTRICAL CONNECTIONS. VERIFY <br />INTEGRITY OF ALL WIRING SYSTEMS TO ASSURE CONTINUITY, ABSENCE OF UNINTENTIONAL GROUNDS, <br />AND INTEGRITY OF REQUIRED GROUNDS. <br />I. CHANGE REQUEST (CHANGE ORDER) APPROVAL: CHANGE REQUESTS WILL NOT BE CONSIDERED <br />UNLESS THE CONTRACTOR'S DETAILED LABOR AND MATERIAL ESTIMATE DESCRIBING THE CHANGE IS <br />SUBMITTED TO THE ARCHITECT ALONG WITH THE CHANGE REQUEST, WITH MATERIAL PRICES AND <br />LABOR UNITS ASSIGNED TO EACH LINE ITEM OF THE ESTIMATE. MATERIAL PRICES SHALL BE THE <br />ACTUAL PRICE PAID BY THE CONTRACTOR FOR MATERIAL PURCHASED OR THE ACTUAL PRICE QUOTED <br />TO THE CONTRACTOR BY THE MATERIAL VENDOR PROPOSED BY THE CONTRACTOR. <br />J. COORDINATION WITH THE WORK OF OTHERS: COORDINATE VVITH EACH TRADE FURNISHING EQUIPMENT <br />REQUIRING ELECTRICAL SERVICE TO INSURE THAT THE CHARACTERISTICS SHOWN ON THE DRAWINGS <br />FOR THE CIRCUIT SERVING THE EQUIPMENT ARE COMPATIBLE WITH THE REQUIREMENTS OF THE <br />EQUIPMENT BEING FURNISHED. CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND ASSOCIATED <br />BRANCH CIRCUITS SHOWN ON THE DRAWINGS TO FEED HVAC EQUIPMENT, KITCHEN EQUIPMENT, <br />ELEVATOR MOTORS, AND OTHER EQUIPMENT HAVE BEEN SELECTED BASED UPON THE <br />CHARACTERISTICS OF EQUIPMENT BY ONE MANUFACTURER AND MAY NOT BE CORRECT FOR THE <br />EQUIPMENT BEING PROVIDED BY THE CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE <br />OPERATING CHARACTERISTICS OF THE EQUIPMENT ACTUALLY BEING PROVIDED AND SHALL PROVIDE <br />AT NO ADDITIONAL COST TO THE OWNER CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND <br />BRANCH CIRCUITS AS REQUIRED BY THAT EQUIPMENT. <br />K. EXISTING WORK: THE EXISTING ELECTRICAL INSTALLATION SHALL REMAIN AS -IS AND IN OPERATION <br />EXCEPT WHERE OTHERWISE REQUIRED. GIVE WRITTEN NOTICE OF ANY UNFORESEEN EXISTING <br />CONDITIONS WHICH MAY AFFECT THE WORK. WORK INVOLVING EXISTING SYSTEMS OR EXISTING <br />SPACES SHALL BE ACCOMPLISHED WITH MINIMUM INCONVENIENCE TO THE OWNER, AND SHALL BE <br />DONE IN A MANNER AND TIME APPROVED BY THE OWNER. ANY INTERRUPTIONS SHALL BE DURING <br />TIMES DESIGNATED BY THE OWNER. <br />L. DEMOLITION: IN THE AREA SHOWN ON THE ARCHITECTURAL DRAWINGS TO BE DEMOLISHED REMOVE ALL <br />EXISTING CONDUITS, CONDUCTORS, BOXES, FIXTURES, SERVICE ENTRANCE CONDUCTORS, <br />DISTRIBUTION EQUIPMENT, AND ALL OTHER ELECTRICAL EQUIPMENT NOT SHOWN TO REMAIN. UNLESS <br />OTHERWISE INDICATED, MATERIAL BEING REMOVED INCLUDING WIRE, CONDUIT, AND HANGING <br />MATERIALS BEING REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE <br />REMOVED FROM THE PREMISES. EQUIPMENT NOTED TO REMAIN THE PROPERTY OF THE OWNER SHALL <br />BE STORED ON SITE AS DIRECTED BY THE ARCHITECT. COORDINATE VVITH OTHER TRADES AND <br />DISCONNECT MOTORS, HEATERS, OR OTHER EQUIPMENT AS REQUIRED FOR THE DEMOLITION OF <br />OTHER TRADES WORK. CUT OFF ALL IN FLOOR CONDUITS, GRIND SMOOTH WITH FLOOR AND PREPARE <br />FOR PATCHING BY OTHERS. REMOVE CONDUCTORS AND DEVICES FROM WALL AND CEILING OUTLETS <br />AND PREPARE OUTLET FOR PATCHING BY OTHERS. CONTRACTOR SHALL DENOTE ALL DEMOLISHED <br />CIRCUITS ON EXISTING PANEL DIRECTORIES AND NOTE ALL SPARE BREAKERS. <br />M. BASIC MATERIALS AND METHODS: <br />1. ALL WORK SHALL BE SUPPORTED FROM STRUCTURAL ELEMENTS OF THE BUILDING, EXCEPT <br />CEILING MOUNTED EQUIPMENT SUCH AS LIGHT FIXTURES, DETECTORS, REMOTE LAMPS, ETC. <br />CEILING MOUNTED EQUIPMENT SHALL BE SUPPORTED FROM CEILING STRUCTURAL MEMBERS, <br />INDEPENDENT OF CEILING TILES. SIZE AND SPACING OF SUPPORTS SHALL BE DETERMINED <br />BY THE LOAD TO BE SUPPORTED SUCH THAT THE WORKING LOAD OF SUPPORTS WILL NOT <br />EXCEED A SAFETY FACTOR OF 4:1. PLASTIC ANCHORS ARE NOT ACCEPTABLE. ELECTRICAL <br />WORK SHALL NOT BE SUPPORTED FROM PIPING, DUCTS, OR WORK OF OTHER TRADES. <br />2. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL SWITCHBOARDS, PANELBOARDS, MOTOR <br />CONTROL CENTERS, STARTERS, DISCONNECTS, PRIMARY SELECTOR SWITCHES, AND <br />TRANSFORMERS. INDICATE EQUIPMENT NAME, CIRCUIT SOURCE AND NUMBER, CIRCUIT SIZE, <br />AMPERE RATING, VOLTAGE AND PHASE. NAMEPLATES SHALL BE BLACK BACKGROUND LAMACOID <br />PLASTIC VVITH 0.25" WHITE LETTERS. <br />3. ALL PENETRATIONS OF FIRE RATED WALLS, SLABS, PARTITIONS, AND CEILINGS SHALL BE <br />FIREPROOFED WITH A U.L. LISTED SYSTEM THAT WILL MAINTAIN THE ORIGINAL FIRE RATING OF <br />THE PENETRATED STRUCTURE. ALL FIREPROOFING MATERIALS APPLIED AT ANY ONE <br />PENETRATION SHALL BE THE PRODUCT OF ONE MANUFACTURER AND SHALL BE APPLIED AS <br />DESCRIBED BY THE UL FIREPROOFING SYSTEM BEING CONSTRUCTED. FIREPROOFING OF <br />SLEEVES, CABLE TRAYS, TROUGHS, AND NIPPLES TO BE USED FOR LOW VOLTAGE CABLES <br />SHALL BE INDEFINITELY NON -HARDENING AND REMOVABLE WITH COMMON HAND TOOLS. <br />4. BACKBOARDS SHALL BE 8 FT. HIGH BY LENGTH SHOWN ON THE DRAWINGS AND SHALL BE <br />UL LABELED FIRE TREATED PLYWOOD. <br />5. PROVIDE ALL POWER WIRING AND CONNECTIONS FOR ALL ELECTRICALLY OPERATED <br />EQUIPMENT. POWER WIRING INCLUDES WIRING THROUGH ANY LINE VOLTAGE CONTROL <br />DEVICES, SUCH AS THERMOSTATS AND MANUAL STARTERS. INSTALL ALL STARTERS AND <br />CONTACTORS EXCEPT THOSE FURNISHED AS AN INTEGRAL PART OF THE EQUIPMENT. <br />6. CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT NOT <br />INSTALLED IN A PLENUM SPACE SHALL BE MADE WITH A SHORT LENGTH OF LIQUIDTIGHT <br />FLEXIBLE CONDUIT, MINIMUM 18", INSTALLED IN A MANNER TO PERMIT MOVEMENT OF <br />EQUIPMENT. <br />7. PERFORM ALL EXCAVATING, BACKFILLING, CUTTING AND REPAIRING REQUIRED FOR <br />INSTALLATION OF ELECTRICAL WORK. <br />8. CONTRACTOR SHALL X-RAY FLOOR SLABS, WALLS, OR CEILING CONCRETE PRIOR TO ALL CORE <br />DRILLINGS. <br />N. CONDUIT: FEEDERS AND BRANCH CIRCUIT HOME RUNS SHALL BE CONSTRUCTED OF EMT WITH ALL <br />STEEL RAINTIGHT OR SET -SCREW FITTINGS. CONNECTORS SHALL BE INSULATED THROAT TYPE. <br />PROVIDE METALLIC BUSHINGS WITH PLASTIC INSERTS FOR 3" OR LARGER. CONDUITS FEEDING OR <br />CONNECTING TO EQUIPMENT PROVIDED BY OTHER TRADES SHALL NOT BE INSTALLED UNTIL SUCH <br />EQUIPMENT IS INSTALLED OR UNTIL SPECIFIC ROUGH -IN INSTRUCTIONS ARE PROVIDED BY THE TRADE <br />PROVIDING THE EQUIPMENT. UNLESS OTHERWISE INDICATED, CONDUITS SHALL BE CONCEALED. <br />RACEWAYS INSTALLED IN OR UNDER SLABS, ON GRADE, OR AS EXTERIOR DUCT BANKS SHALL BE PVC <br />SCHEDULE 40 OR 80. RUN EXPOSED CONDUITS PARALLEL OR PERPENDICULAR TO STRUCTURAL <br />ELEMENTS. TWO OR MORE RACEWAYS RUN TOGETHER SHALL BE INSTALLED ON GANG TRAPEZE TYPE <br />HANGERS. SUCH RACEWAYS ASSEMBLIES SHALL BE RUN PARALLEL OR PERPENDICULAR TO <br />STRUCTURAL ELEMENTS. CONDUITS EMBEDDED IN SLABS SHALL HAVE A MINIMUM OF 1" COVER OF <br />CONCRETE ON ALL SIDES. OUTSIDE DIAMETER OF CONDUIT SHALL NOT EXCEED 1/3 OF THE SLAB <br />THICKNESS. PROVIDE 0.25" NYLON PULL TAPE IN ALL EMPTY CONDUITS. BRANCH CIRCUITS MAY <br />UTILIZE TYPE MC ARMORED CABLE ASSEMBLY WITH COPPER CONDUCTORS AND FULL SIZE <br />EQUIPMENT GROUNDING CONDUCTORS FOR INDIVIDUAL DROPS TO DEVICES. TYPE MC CABLE SHALL <br />BE SUPPORTED AT 48" INTERVALS AND SHALL NOT LAY ON THE CEILING GRID OR INTERFERE WITH THE <br />REMOVAL OF CEILING. <br />0. CONDUCTORS: ALL BUILDING WIRE SHALL BE 600 VOLT RATED THHN OR THWN COPPER, STRANDED <br />0 SMALLER UNLESS APPLIED FOR CONTROL. <br />FOR SIZES #8AWG AND LARGER, SOLID FOR SIZES 1 AND SMA L U O O <br />ALL BUILDING WIRE AND SPECIAL CABLES FOR SYSTEMS SHALL BE INSTALLED IN A RACEWAY. ALL <br />WIRE AND CABLE SHALL BE DELIVERED TO THE JOBSITE IN ORIGINAL UNBROKEN PACKAGES, <br />CARTONS OR REELS, WITH THE MANUFACTURERS NAME, UL LABEL, AND CHARACTERISTICS OF THE <br />PRODUCT PLAINLY VISIBLE. ALL WIRE AND CABLE SHALL BE MANUFACTURED IN THE UNITED STATES <br />OF AMERICA. WIRES SHALL BE COLOR CODED AS FOLLOWS (A,B,C,N,G): 120/208-BLACK, RED, BLUE, <br />WHITE, GREEN; 480/277 - BROWN, ORANGE, YELLOW, GRAY, GREEN. SPLICES SHALL BE COMPRESSION <br />TYPE. CONTROL CONDUCTORS SHALL BE TERMINATED WITH INSULATED CONNECTORS, T&B STAKON. <br />120 VOLT CIRCUITS WITH HOMERUN LENGTH OVER 125 FEET AND 277 VOLT CIRCUITS WITH A <br />HOMERUN LENGTH OVER 250 FEET SHALL HAVE #10 MINIMUM HOMERUN CONDUCTORS. ALL THREE <br />PHASE BRANCH CIRCUITS WITH A COMMON NEUTRAL SHALL HAVE #10 MINIMUM NEUTRAL. <br />P. BOXES: OUTLET BOXES SHALL BE SHEET STEEL, MINIMUM 4" SQUARE, MINIMUM 1.5" DEEP, WITH <br />PLASTER RING IN PLASTER OR BRICK CONSTRUCTION. OUTLETS BOXES IN POURED CONCRETE SHALL <br />BE CONCRETE RINGS. MASONRY BOXES SHALL BE USED IN MASONRY OR TILE CONSTRUCTION. <br />OUTLET BOXES FOR SURFACE ALUMINUM RACEWAY SHALL BE 4-11/16 WITH PLASTER RINGS <br />ORIENTED HORIZONTALLY. BOXES SHALL BE SECURELY ANCHORED IN PLACE, AND SHALL BE <br />SUPPORTED INDEPENDENT OF THE RACEWAY SYSTEM. PULL BOXES SHALL BE GALVANIZED SHEET <br />STEEL, MINIMUM 12 GAUGE, WITH SCREW COVERS, AND WELDED CONSTRUCTION. WELDS SHALL BE <br />COLD GALVANIZED. USING PERMANENT WATER PROOF VVIDE BLACK MARKER, CLEARLY LABEL COVER <br />OF ALL BRANCH CIRCUIT JUNCTION AND PULL BOXES WITH PANEL AND CIRCUIT NUMBER OF CIRCUITS <br />CONTAINED IN OR PASSING THROUGH THE BOX. BRANCH CIRCUIT AND FEEDER JUNCTION AND PULL <br />BOXES USED WITH EMERGENCY FEEDERS AND CIRCUITS SHALL BE PAINTED RED. PROVIDE P-TOUCH <br />OR DYMO LABELS ON COVER OF EACH FEEDER PULL OR JUNCTION BOX INDICATING FEEDER <br />DESIGNATION, SOURCE, LOAD, AND VOLTAGE. <br />Q. WIRING DEVICES: SWITCHES FOR LIGHTING CIRCUITS SHALL BE 120/277 VOLT, 20 AMP, A.C. ONLY, <br />QUIET TYPE, WITH GROUND BONDING SCREW, SPECIFICATION GRADE. MOMENTARY CONTACT <br />SWITCHES SHALL BE SINGLE POLE DOUBLE THROW, CENTER OFF GE #5935 OR EQUAL. DUPLEX <br />RECEPTACLES SHALL BE 15 AMP HUBBELL 5262 OR EQUAL. DEDICATED DUPLEX RECEPTACLES SHALL <br />BE ORANGE 20AMP HUBBELL IG5362 OR EQUAL. SPECIAL RECEPTACLES SHALL BE OF SIMILAR <br />CONSTRUCTION. FACE PLATES SHALL BE SMOOTH NYLON OR THERMOSET PLASTIC. ADJACENT <br />OUTLETS SHALL BE INSTALLED IN MULTI -GANG BOXES VVITH A SINGLE MULTI -GANG FACE PLATE. <br />RECEPTACLES CONNECTED TO AN EMERGENCY CIRCUIT SHALL BE RED. COORDINATE COLOR OF <br />DEVICES AND FACEPLATE WITH ARCHITECT. <br />R. GROUNDING: ALL FEEDERS AND BRANCH CIRCUITS SHALL BE PROVIDED WITH INSULATED GREEN <br />EQUIPMENT GROUNDING CONDUCTOR. CONDUIT GROUNDS ONLY ARE NOT PERMITTED, <br />S. LIGHTING: SPARE FLUORESCENT LAMPS SHALL MATCH BUILDING STANDARD UNLESS OTHERWISE <br />NOTED. INCANDESCENT LAMPS SHALL BE 130VOLT. NEW BALLASTS SHALL BE SOILD STATE <br />ELECTRONIC. EXIT FIXTURES SHALL MATCH BUILDING STANDARD. FIXTURE LOCATIONS SHALL BE AS <br />SHOWN ON THE REFLECTED CEILING PLAN. PROVIDE LAY -IN FIXTURES WITH TWO REMOVABLE CLIPS <br />ATTACHING FIXTURE TO CEILING GRID. FLANGED FIXTURES SHOWN TO BE INSTALLED IN CONTINUOUS <br />ROWS SHALL NOT HAVE INTERMEDIATE FLANGES. ALL PENDANT FIXTURES SHALL BE MOUNTED TO <br />STRUCTURE. SEISMIC SUPPORT WIRES AND/OR COMPRESSION STRUTS FOR LAY -IN FIXTURES SHALL <br />BE SUBJECT TO LOCAL AHJ LATEST REQUIREMENTS. <br />T. FIRE ALARM DEVICES: NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE VVITH EXISTING BUILDING <br />ADDRESSABLE FIRE ALARM SYSTEM. INSTALL NEW DEVICES AND CONNECT TO NEAREST SIGNALING <br />OR NOTIFICATION DEVICE CIRCUIT VVITHIN THE AREA. CONTRACTOR SHALL VERIFY CIRCUIT HAS <br />CAPACITY FOR ADDED LOAD. SYSTEM SHALL BE CERTIFIED BY FIRE ALARM VENDOR AFTER <br />COMPLETION OF WORK. <br />U. PANELBOARDS: DEAD FRONT PANEL CONSTRUCTION WITH SEPARATELY MOUNTED INTERIOR TRIM. <br />MAIN AND BRANCH DEVICES SHALL BE BOLT -ON. MULTI -POLE BREAKERS SHALL BE COMMON TRIP. <br />WIDTH SHALL NOT EXCEED 22" FOR PANELBOARD AND ENCLOSURE SHALL MATCH BUILDING <br />STANDARD. PROVIDE GROUND BUS IN PANELBOARD AND PROVIDE DEVICE MOUNTING HARDWARE <br />WHERE A SPACE IS SCHEDULED. PANEL AND OCPD SHORT CIRCUIT RATINGS SHALL BE AT LEAST 10% <br />GREATER THAN AVAILABLE SHORT CIRCUIT CURRENT AT PANELBOARD. <br />V. DRY -TYPE TRANSFORMERS: TRANSFORMERS SHALL BE DRY -TYPE, ENCLOSED, SELF -COOLED, <br />VENTILATED TYPE, DEAD -FRONT DRIP PROOF. PRIMARY AND SECONDARY TAPS SHALL BE ACCESSIBLE <br />FROM THE FRONT. TRANSFORMERS SHALL MEET OR EXCEED BUILDING STANDARD TRANSFORMERS <br />SPECIFICATIONS. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR IN THE PRIMARY FEED TO THE <br />TRANSFORMER, SUPPLEMENTAL GROUND TO NEAREST ACCESSIBLE PRIMARY STRUCTURAL MEMBER <br />OR EQUIPMENT ROOM GROUND BUS BAR. SIZE PER NEC AND RUN IN CONDUIT WITH BOND BUSHING AT <br />EACH END. NEUTRAL AND GROUNDING CONDUCTOR SHALL BE BONDED TO ENCLOSURE. <br />9 <br />U <br />z <br />c� <br />Z� o <br />r <br />W <br />Lo w <br />a C� <br />U ti � Z <br />Cn w <br />CC W U <br />LL] <br />I— UzU co <br />v <br />N� <br />N � <br />Cn <br />z <br />U) <br />m <br />p• G E N `g�"�tc'ji <br />40 w <br />N <br />4tlF <br />Z O RI %% <br />� % ON AL <br />16018 <br />0 <br />rn <br />Q <br />w <br />Z <br />w <br />c> <br />J <br />m <br />d <br />Q <br />U <br />Z <br />Q <br />Q <br />w <br />Y <br />Z <br />cro <br />w <br />w <br />J <br />Q REVISION #2 11/16/2017 <br />CONTRACT DATE: 08.13.2017 <br />BUILDING TYPE: ONE-OFF <br />PLAN VERSION: <br />SITE NUMBER: <br />STORE NUMBER: <br />Restaurant Shell <br />Zephyr Plaza <br />ZEPHYRHILLS, FL <br />ELECTRICAL <br />GENERAL <br />NOTES <br />& LEGNED <br />EO.0 <br />PLOT DATE: Nov 17, 2017 - 11:12am <br />