ELECTRICAL LEGEND
<br />❑O �O
<br />FLUORESCENT TROFFER, TYPE AS NOTED
<br />DUPLEX RECEPTACLE
<br />18" AFF OR AS NOTED, NEMA 5-20R
<br />FLUORESCENT TROFFER, TYPE AS NOTED
<br />SP @=
<br />SURGE PROTECTION DUPLEX RECEPTACLE, 20A, 125V
<br />PROVIDE WITH EMERGENCY BALLAST
<br />HUBBELL CATAO HBL5360SA, NEMA 5-20R
<br />®
<br />FLUORESCENT TROFFER, TYPE AS NOTED
<br />0=
<br />DUPLEX RECEPTACLE
<br />ABOVE COUNTER OR AS NOTED, NEMA 5-20R
<br />®
<br />FLUORESCENT TROFFER, TYPE AS NOTED
<br />QUAD RECEPTACLE
<br />PROVIDE WITH EMERGENCY BALLAST
<br />18" AFF OR AS NOTED, NEMA 5-20R
<br />O
<br />RECESSED CAN FIXTURE, TYPE AS NOTED
<br />IG
<br />DUPLEX RECEPTACLE
<br />18" AFF OR AS NOTED, NEMA 5-20R
<br />O
<br />RECESSED CAN FIXTURE, TYPE AS NOTED
<br />SPECIAL PURPOSE RECEPTACLE
<br />PROVIDE WITH EMERGENCY BALLAST
<br />18" AFF OR AS NOTED, SEE SCHEDULE
<br />F-<>--i
<br />FLUORESCENT STRIP FIXTURE
<br />Fo/ JO
<br />WALL / CEILING MOUNTED JUNCTION BOX
<br />60/3/1
<br />UNFUSED DISCONNECT SWITCH
<br />WALL MOUNTED FIXTURE, TYPE AS NOTED
<br />❑i
<br />RATING/POLES/NEMA RATING
<br />60/3/3R/40
<br />FUSED DISCONNECT SWITCH
<br />PENDANT FIXTURE, TYPE AS NOTED
<br />RATING/POLES/NEMA RATING/FUSE SIZE
<br />PENDANT FIXTURE, TYPE AS NOTED
<br />MOTOR
<br />PROVIDE WITH EMERGENCY BALLAST
<br />•j••�•;•
<br />TRACK LIGHT FIXTURE, TYPE AS NOTED
<br />�II
<br />GROUND
<br />EMERGENCY LIGHT
<br />0
<br />TELEPHONE OUTLET, PROVIDE 4- BOX
<br />SINGLE GANG PLASTER RING, 1" C STUBBED 6" ABOVE CEILING
<br />TELEPHONE OUTLET, PROVIDE 4" BOX
<br />EXIT/EMERGENCY LIGHT COMBINATION
<br />-�
<br />HALF SHADED- INDICATES SINGLE JACK, FULL SHADED INDICATES
<br />TWO JACKS. NETWORK WIRING SYSTEM:
<br />®
<br />CEILING MOUNTED EXIT SIGN
<br />CAT 5E 110, RJ45 JACK WIRED TO SPEC 568B MODULAR JACK
<br />PROVIDE ONE JACK AND ONE POSITION IVORY FACEPLATE AT
<br />WALL MOUNTED EXIT SIGN
<br />SINGLE JACK LOCATIONS AND TWO AT DOUBLE LOCATIONS.
<br />CONTACT PHIL BENTON, 678-966-3335 FOR INFO.
<br />DOUBLE BOX, AS DESCRIBED ABOVE EXCEPT CONNECT 2 LINES
<br />SINGLE POLE SWITCH, 44" AFF
<br />-
<br />DIRECTLY FROM PUNCH BLOCK (D-MARK) TO DOUBLE BOX IN
<br />MANAGEROFFICE
<br />TWO SINGLE POLE SWITCHES GANGED TOGETHER
<br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF
<br />THREE SINGLE POLE SWITCHES GANGED TOGETHER
<br />SINGLE BOX- MANAGER'S/FAX, DEDICATED ANALOG TELEPHONE
<br />44" AFF
<br />®
<br />LINE WITH RINGMASTER, CAT 5E, RJ11 - NOT TO BE ROUTED
<br />THROUGH TELEPHONE SYSTEM. TERMINATE AT PUNCH BLOCK
<br />THREE WAY SWITCH, 44" AFF
<br />(D-MARK)
<br />TWO THREE WAY SWITCHES GANGED TOGETHER
<br />SINGLE BOX- DSL/LSR DEDICATED ANALOG TELEPHONE LINE
<br />FOR INNER/OUTER CONTROL OF LAMPS, 44" AFF
<br />0
<br />WITH RINGMASTER, CAT 5E, RJ11 - NOT TO BE ROUTED THRU
<br />TELEPHONE SYSTEM, TERMINATE AT PUNCH BLOCK (D-MARK)
<br />FOUR WAY SWITCH, 44" AFF
<br />4
<br />WALL BOX DIMMER 1000W UNLESS NOTED DIFFERENTLY
<br />all
<br />SPEAKER STROBE
<br />44" AFF
<br />$WP
<br />WEATHER PROOF SWITCH, 44" AFF
<br />QN
<br />HORN
<br />$M
<br />MOTOR RATED SWITCH, 44" AFF OR AS NOTED
<br />IN
<br />PULL STATION o
<br />$OS
<br />COMBINATION SWITCH AND OCCUPANCY SENSOR, 44" AFF
<br />Q
<br />FIRE ALARM STROBE, MIN 75 CANDELA
<br />CEILING / WALL MOUNT
<br />$T
<br />DIGITAL TIMER SWITCH, 44" AFF
<br />DUCT MOUNTED SMOKE DETECTOR
<br />®X
<br />CEILING MOUNTED OCCUPANCY SENSOR
<br />OS
<br />SMOKE DETECTOR
<br />�X
<br />WALL MOUNTED OCCUPANCY SENSOR, 44" AFF
<br />OH
<br />HEAT DETECTOR
<br />T�
<br />TIME CLOCK
<br />TS
<br />TAMPER SWITCH
<br />®�
<br />SINGLE DOME, CEILING AND WALL MOUNTED SECURITY
<br />0FLOW
<br />SWITCH
<br />CAMERAS. FURNISHED AND INSTALLED BY OTHERS,
<br />®
<br />PHOTO CELL
<br />a'�-�
<br />RACEWAY CONCEALED IN WALL OR ABOVE CEILING
<br />®
<br />8" CONE SPEAKER IN CEILING
<br />RACEWAY EXPOSED
<br />EC TO PROVIDE BLACK SPEAKER
<br />/0-\
<br />8" CONE SPEAKER IN WALL
<br />���
<br />RACEWAY CONCEALED IN FLOOR SLAB, BELOW SLAB OR GRADE
<br />EC TO PROVIDE BLACK SPEAKER
<br />BELOW SLAB OR GRADE, OR UNDER RAISED ACCESS FLOOR
<br />1
<br />VOLUME CONTROL
<br />- 0
<br />DENOTES CONDUIT TURNING UP IN PLAN VIEW
<br />PLYWOOD EQUIPMENT BACKBOARD
<br />-------- 0
<br />DENOTES CONDUIT TURNING DOWN IN PLAN VIEW
<br />4'X8' UNLESS NOTED OTHERWISE
<br />CC
<br />CLOSED CIRCUIT TELEVISION CAMERA
<br />STUB UP
<br />COAXIAL CABLE OUTLET
<br />XXXX
<br />SHORT CIRCUIT AVAILABLE CURRENT
<br />(NOTE: ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS AND ARE USED AS APPLICABLE TO THIS PROJECT)
<br />ABBREVIATIONS
<br />A, AMPS
<br />AMPERES
<br />FLA
<br />FULL LOAD AMPERES
<br />NO
<br />NORMALLY OPEN,
<br />A/C
<br />AIR CONDITIONER
<br />GND
<br />GROUND
<br />NUMBER
<br />AC
<br />ALTERNATING CURRENT
<br />GALV
<br />GALVANIZED
<br />NTS
<br />NOT TO SCALE
<br />AF
<br />AMPERE FRAME
<br />GRS
<br />GALVANIZED RIGID STEEL
<br />PNL
<br />PANELBOARD
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />GFCI
<br />GROUND FAULT
<br />PVC
<br />POLYVINYL CHLORIDE
<br />AFG
<br />ABOVE FINISHED GRADE
<br />CIRCUIT INTERRUPTER
<br />RGS
<br />RIGID GALVANIZED
<br />AIC
<br />AMPERE
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />RMC
<br />STEEL CONDUIT
<br />RIGID METALLIC
<br />INTERRUPTING CURRENT
<br />AL
<br />ALUMINUM
<br />HD
<br />HEAT DETECTOR
<br />CONDUIT (GALVANIZED)
<br />ANSI
<br />AMERICAN NATIONAL
<br />HP
<br />HORSEPOWER
<br />RMS
<br />ROOT -MEAN -SQUARE
<br />STANDARDS INSTITUTE
<br />IMC
<br />INTERMEDIATE METAL CONDUIT
<br />RNC
<br />RIGID NON-METALLIC
<br />AWG
<br />AMERICAN WIRE GAUGE
<br />ISC
<br />INTERRUPTING SHORT CIRCUIT
<br />CONDUIT
<br />BC
<br />BARE COPPER
<br />IG
<br />ISOLATED GROUND
<br />SCA
<br />SHORT CIRCUIT
<br />BKBD
<br />BACKBOARD
<br />INST
<br />INSTANTANEOUS
<br />AVAILABLE
<br />JB
<br />JUNCTION BOX
<br />SWBD
<br />SWITCHBOARD
<br />C
<br />CONDUIT
<br />KAIC
<br />KILO (THOUSAND) AMPERES
<br />SWGR
<br />SWITCHGEAR
<br />CB
<br />CIRCUIT BREAKER
<br />INTERRUPTING CAPACITY
<br />TBD
<br />TO BE DETERMINED
<br />CKT
<br />CIRCUIT
<br />KCMIL
<br />KILO (THOUSAND)
<br />TCP
<br />TEMPERATURE CONTROL
<br />CU
<br />COPPER
<br />CIRCULAR MILS
<br />PANEL
<br />DIST
<br />DISTRIBUTION
<br />KV
<br />KILO (THOUSAND) VOLTS
<br />TD
<br />TIME DELAY
<br />DIN
<br />DOWN
<br />KVA
<br />KILO (THOUSAND)
<br />TEL
<br />TELEPHONE
<br />DP
<br />DISTRIBUTION PANEL
<br />VOLT-AMPERES
<br />TVSS
<br />TRANSIENT VOLTAGE
<br />DWG
<br />DRAWING
<br />KW
<br />KILO (THOUSAND) WATTS
<br />SURGE SUPPRESSION
<br />EB
<br />ENCASED BURIAL
<br />KWH
<br />KILO (THOUSAND) WATT-HOURS
<br />TYP
<br />TYPICAL
<br />EC
<br />EMPTY CONDUIT
<br />LFMC
<br />LIQUID -TIGHT FLEXIBLE
<br />UG
<br />UNDERGROUND
<br />EEW
<br />ENERGIZED ELECTRICAL WORK
<br />METAL CONDUIT
<br />EGC
<br />EQUIPMENT GROUNDING
<br />MCB
<br />MAIN CIRCUIT BREAKER
<br />UL
<br />UNDERWRITER'S LABORATORIES
<br />CONDUCTOR
<br />MCM
<br />THOUSAND CIRCULAR MILS
<br />UON
<br />UNLESS OTHERWISE
<br />ELR
<br />END -OF -LINE RESISTOR
<br />MCCB
<br />MOLDED CASE
<br />UNDERGROUND PULLBOX
<br />EWC
<br />ELECTRIC WATER COOLER
<br />MLO
<br />MAIN LUGS ONLY
<br />V
<br />VOLTS
<br /><E>
<br />EXISTING
<br />N
<br />NEUTRAL
<br />VA
<br />VOLT-AMPERES
<br /><ER>
<br />EXISTING TO REMAIN
<br />NEC
<br />NATIONAL ELECTRICAL
<br />VFD
<br />VARIABLE
<br /><EX>
<br />EXISTING
<br />CODE
<br />FREQUENCY DRIVE
<br />FA
<br />FIRE ALARM
<br />NESC
<br />NATIONAL ELECTRICAL
<br />WH
<br />WATER HEATER
<br />FAA
<br />FIRE ALARM ANNUNCIATOR
<br />SAFETY CODE
<br />WP
<br />WEATHERPROOF
<br />ELECTRICAL SPECIFICATIONS
<br />A. DEFINITIONS:
<br />1. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR OPERATION.
<br />2. "INSTALL": RECEIVE, MOUNT, AND CONNECT, COMPLETE AND READY FOR OPERATION.
<br />3. "FURNISH": SUPPLY, DELIVER TO JOB SITE, PROTECT AND STORE.
<br />B. WORK INCLUDED: PROVIDE ALL LABOR, TOOLS, MATERIAL, EXCAVATION, BACKFILL, CUTTING, PATCHING,
<br />TESTING, ADJUSTING, AND TRADE COORDINATION REQUIRED FOR A COMPLETE AND FULLY
<br />OPERATIONAL INSTALLATION, AS DESCRIBED ON THE DRAWINGS OR IN THE SPECIFICATIONS.
<br />C. CODES, RULES, AND REGULATIONS: COMPLY WITH ALL CODES ENFORCED BY THE LOCAL INSPECTION
<br />AUTHORITY, THE EDITION OF THE NATIONAL ELECTRICAL CODE BEING ENFORCED FOR THIS PROJECT
<br />BY THE LOCAL INSPECTION AUTHORITY, ALL APPLICABLE LAWS AND ORDINANCE, NFPA FIRE CODES,
<br />STANDARD BUILDING CODE. GIVE ALL NECESSARY NOTICES, OBTAIN ALL REQUIRED PERMITS, AND PAY
<br />ALL INSPECTION AND OTHER FEES REQUIRED BY AUTHORITIES HAVING JURISDICTION OVER THE WORK.
<br />D. MATERIALS: ALL MATERIAL SHALL BE NEW, AND SHALL COMPLY WITH THE INDICATED STANDARDS. ALL
<br />MATERIAL SHALL BE UL LABELED OR UL LISTED. ALL MATERIAL SHALL BE OF A SUITABLE TYPE AND
<br />RATING FOR THE INTENDED USE, AND SHALL BE INSTALLED IN CONFORMANCE VVITH THE INSTRUCTIONS
<br />AND RECOMMENDATIONS OF THE MANUFACTURER.
<br />E. DRAWINGS
<br />1. THE DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL OF THE REQUIRED DETAILS
<br />OF THE WORK. ALL MATERIALS CUSTOMARILY CONSIDERED TO BE A PART OF THE ELECTRICAL
<br />WORK AND REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION SHALL BE PROVIDED
<br />WITHOUT ADDITIONAL COST TO THE OWNER.
<br />2. THE CONTRACTOR SHALL REFER ALSO TO THE ARCHITECTURAL DRAWINGS AND TO THE
<br />DRAWINGS OF ALL OTHER TRADES TO COORDINATE THE ELECTRICAL INSTALLATION. WHERE
<br />ELECTRICAL EQUIPMENT IS SHOWN ON ARCHITECTURAL DRAWINGS OR DETAILS, THE EQUIPMENT
<br />SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL DRAWINGS.
<br />3. EQUIPMENT OF OTHER TRADES IS SHOWN SCHEMATICALLY ON THE ELECTRICAL DRAWINGS. THE
<br />CONTRACTOR SHALL EXAMINE THE DRAWINGS OF THE TRADE PROVIDING THE EQUIPMENT
<br />BEFORE ROUGHING IN THE CONNECTIONS FOR IT. THE CONTRACTOR SHALL CONNECT THE
<br />EQUIPMENT WHERE ACTUALLY INSTALLED, INCLUDING WIRING THROUGH ANY LINE VOLTAGE
<br />CONTROLLERS, WITHOUT ANY ADDITIONAL COST TO THE OWNER.
<br />4. PRIOR TO ROUGHING IN CIRCUITS FOR EQUIPMENT FURNISHED BY OTHER TRADES, AND PRIOR
<br />TO RELEASING FOR MANUFACTURE PANELBOARDS, STARTERS OR MOTOR CONTROL CENTERS
<br />FEEDING SUCH EQUIPMENT, THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL
<br />PROVISIONS BEING PLANNED WITH THE TRADE PROVIDING THE EQUIPMENT AND SUBMIT ANY
<br />CONFLICTS IN WRITING TO THE ARCHITECT.
<br />5. THE ARCHITECT MAY DIRECT THE RELOCATION OF ANY ELECTRICAL OUTLET, FIXTURE, OR OTHER
<br />EQUIPMENT TO A LOCATION WITHIN 10 FEET OF THE LOCATION SHOWN ON THE DRAWINGS AT NO
<br />ADDITIONAL COST TO THE OWNER PROVIDED SUCH RELOCATION IS DIRECTED PRIOR TO THE
<br />INSTALLATION OF THE OUTLET, FIXTURE OR EQUIPMENT BEING RELOCATED.
<br />D. SUBMITTAL DOCUMENTS: PRODUCT DATA AND SHOP DRAWINGS SHALL BE SUBMITTED IN SIX COPIES TO
<br />THE ARCHITECT FOR REVIEW PRIOR TO THE RELEASE OF THE MATERIAL FOR MANUFACTURE. REVIEW
<br />OF SUBMITTALS BY THE ARCHITECT WILL BE ONLY FOR GENERAL CONFORMANCE WITH THE DRAVINGS
<br />AND SPECIFICATIONS. REVIEW WILL BE MADE ONLY OF INFORMATION CLEARLY AND SPECIFICALLY
<br />INDICATED IN THE SUBMITTAL, AND DOES NOT IMPLY THE ACCEPTABILITY OF DETAILS WHICH ARE NOT
<br />SO DESCRIBED IN THE SUBMITTAL. REVIEW OF THE SUBMITTAL DOCUMENTS BY THE ARCHITECT DOES
<br />NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO COMPLY WITH ALL REQUIREMENTS OF THE
<br />DRAWINGS AND SPECIFICATIONS. SUBMITTAL IS REQUIRED FOR PANELBOARDS AND LOADCENTERS,
<br />LIGHT FIXTURES, WIRING DEVICES, FIRE ALARM DEVICES, AND SURFACE ALUMINUM RACEWAY.
<br />G. AS -BUILT DRAWINGS: AS -BUILT DRAWINGS SHALL BE MAINTAINED AT THE JOBSITE, AND SHALL BE
<br />AVAILABLE FOR REVIEW DURING CONSTRUCTION, AS -BUILT DRAWINGS SHALL BE KEPT CURRENT
<br />DURING THE COURSE OF CONSTRUCTION OF THE WORK. SUBMIT AS -BUILT DRAWINGS TO THE
<br />ARCHITECT AT THE COMPLETION OF THE PROJECT.
<br />H. TESTING: TEST ALL PARTS OF THE WORK TO VERIFY COMPLIANCE WITH THE DRAWINGS AND
<br />SPECIFICATIONS. VERIFY TIGHTNESS OF ALL MECHANICAL AND ELECTRICAL CONNECTIONS. VERIFY
<br />INTEGRITY OF ALL WIRING SYSTEMS TO ASSURE CONTINUITY, ABSENCE OF UNINTENTIONAL GROUNDS,
<br />AND INTEGRITY OF REQUIRED GROUNDS.
<br />I. CHANGE REQUEST (CHANGE ORDER) APPROVAL: CHANGE REQUESTS WILL NOT BE CONSIDERED
<br />UNLESS THE CONTRACTOR'S DETAILED LABOR AND MATERIAL ESTIMATE DESCRIBING THE CHANGE IS
<br />SUBMITTED TO THE ARCHITECT ALONG WITH THE CHANGE REQUEST, WITH MATERIAL PRICES AND
<br />LABOR UNITS ASSIGNED TO EACH LINE ITEM OF THE ESTIMATE. MATERIAL PRICES SHALL BE THE
<br />ACTUAL PRICE PAID BY THE CONTRACTOR FOR MATERIAL PURCHASED OR THE ACTUAL PRICE QUOTED
<br />TO THE CONTRACTOR BY THE MATERIAL VENDOR PROPOSED BY THE CONTRACTOR.
<br />J. COORDINATION WITH THE WORK OF OTHERS: COORDINATE VVITH EACH TRADE FURNISHING EQUIPMENT
<br />REQUIRING ELECTRICAL SERVICE TO INSURE THAT THE CHARACTERISTICS SHOWN ON THE DRAWINGS
<br />FOR THE CIRCUIT SERVING THE EQUIPMENT ARE COMPATIBLE WITH THE REQUIREMENTS OF THE
<br />EQUIPMENT BEING FURNISHED. CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND ASSOCIATED
<br />BRANCH CIRCUITS SHOWN ON THE DRAWINGS TO FEED HVAC EQUIPMENT, KITCHEN EQUIPMENT,
<br />ELEVATOR MOTORS, AND OTHER EQUIPMENT HAVE BEEN SELECTED BASED UPON THE
<br />CHARACTERISTICS OF EQUIPMENT BY ONE MANUFACTURER AND MAY NOT BE CORRECT FOR THE
<br />EQUIPMENT BEING PROVIDED BY THE CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE
<br />OPERATING CHARACTERISTICS OF THE EQUIPMENT ACTUALLY BEING PROVIDED AND SHALL PROVIDE
<br />AT NO ADDITIONAL COST TO THE OWNER CIRCUIT BREAKERS, FUSES, DISCONNECT SWITCHES AND
<br />BRANCH CIRCUITS AS REQUIRED BY THAT EQUIPMENT.
<br />K. EXISTING WORK: THE EXISTING ELECTRICAL INSTALLATION SHALL REMAIN AS -IS AND IN OPERATION
<br />EXCEPT WHERE OTHERWISE REQUIRED. GIVE WRITTEN NOTICE OF ANY UNFORESEEN EXISTING
<br />CONDITIONS WHICH MAY AFFECT THE WORK. WORK INVOLVING EXISTING SYSTEMS OR EXISTING
<br />SPACES SHALL BE ACCOMPLISHED WITH MINIMUM INCONVENIENCE TO THE OWNER, AND SHALL BE
<br />DONE IN A MANNER AND TIME APPROVED BY THE OWNER. ANY INTERRUPTIONS SHALL BE DURING
<br />TIMES DESIGNATED BY THE OWNER.
<br />L. DEMOLITION: IN THE AREA SHOWN ON THE ARCHITECTURAL DRAWINGS TO BE DEMOLISHED REMOVE ALL
<br />EXISTING CONDUITS, CONDUCTORS, BOXES, FIXTURES, SERVICE ENTRANCE CONDUCTORS,
<br />DISTRIBUTION EQUIPMENT, AND ALL OTHER ELECTRICAL EQUIPMENT NOT SHOWN TO REMAIN. UNLESS
<br />OTHERWISE INDICATED, MATERIAL BEING REMOVED INCLUDING WIRE, CONDUIT, AND HANGING
<br />MATERIALS BEING REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE
<br />REMOVED FROM THE PREMISES. EQUIPMENT NOTED TO REMAIN THE PROPERTY OF THE OWNER SHALL
<br />BE STORED ON SITE AS DIRECTED BY THE ARCHITECT. COORDINATE VVITH OTHER TRADES AND
<br />DISCONNECT MOTORS, HEATERS, OR OTHER EQUIPMENT AS REQUIRED FOR THE DEMOLITION OF
<br />OTHER TRADES WORK. CUT OFF ALL IN FLOOR CONDUITS, GRIND SMOOTH WITH FLOOR AND PREPARE
<br />FOR PATCHING BY OTHERS. REMOVE CONDUCTORS AND DEVICES FROM WALL AND CEILING OUTLETS
<br />AND PREPARE OUTLET FOR PATCHING BY OTHERS. CONTRACTOR SHALL DENOTE ALL DEMOLISHED
<br />CIRCUITS ON EXISTING PANEL DIRECTORIES AND NOTE ALL SPARE BREAKERS.
<br />M. BASIC MATERIALS AND METHODS:
<br />1. ALL WORK SHALL BE SUPPORTED FROM STRUCTURAL ELEMENTS OF THE BUILDING, EXCEPT
<br />CEILING MOUNTED EQUIPMENT SUCH AS LIGHT FIXTURES, DETECTORS, REMOTE LAMPS, ETC.
<br />CEILING MOUNTED EQUIPMENT SHALL BE SUPPORTED FROM CEILING STRUCTURAL MEMBERS,
<br />INDEPENDENT OF CEILING TILES. SIZE AND SPACING OF SUPPORTS SHALL BE DETERMINED
<br />BY THE LOAD TO BE SUPPORTED SUCH THAT THE WORKING LOAD OF SUPPORTS WILL NOT
<br />EXCEED A SAFETY FACTOR OF 4:1. PLASTIC ANCHORS ARE NOT ACCEPTABLE. ELECTRICAL
<br />WORK SHALL NOT BE SUPPORTED FROM PIPING, DUCTS, OR WORK OF OTHER TRADES.
<br />2. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL SWITCHBOARDS, PANELBOARDS, MOTOR
<br />CONTROL CENTERS, STARTERS, DISCONNECTS, PRIMARY SELECTOR SWITCHES, AND
<br />TRANSFORMERS. INDICATE EQUIPMENT NAME, CIRCUIT SOURCE AND NUMBER, CIRCUIT SIZE,
<br />AMPERE RATING, VOLTAGE AND PHASE. NAMEPLATES SHALL BE BLACK BACKGROUND LAMACOID
<br />PLASTIC VVITH 0.25" WHITE LETTERS.
<br />3. ALL PENETRATIONS OF FIRE RATED WALLS, SLABS, PARTITIONS, AND CEILINGS SHALL BE
<br />FIREPROOFED WITH A U.L. LISTED SYSTEM THAT WILL MAINTAIN THE ORIGINAL FIRE RATING OF
<br />THE PENETRATED STRUCTURE. ALL FIREPROOFING MATERIALS APPLIED AT ANY ONE
<br />PENETRATION SHALL BE THE PRODUCT OF ONE MANUFACTURER AND SHALL BE APPLIED AS
<br />DESCRIBED BY THE UL FIREPROOFING SYSTEM BEING CONSTRUCTED. FIREPROOFING OF
<br />SLEEVES, CABLE TRAYS, TROUGHS, AND NIPPLES TO BE USED FOR LOW VOLTAGE CABLES
<br />SHALL BE INDEFINITELY NON -HARDENING AND REMOVABLE WITH COMMON HAND TOOLS.
<br />4. BACKBOARDS SHALL BE 8 FT. HIGH BY LENGTH SHOWN ON THE DRAWINGS AND SHALL BE
<br />UL LABELED FIRE TREATED PLYWOOD.
<br />5. PROVIDE ALL POWER WIRING AND CONNECTIONS FOR ALL ELECTRICALLY OPERATED
<br />EQUIPMENT. POWER WIRING INCLUDES WIRING THROUGH ANY LINE VOLTAGE CONTROL
<br />DEVICES, SUCH AS THERMOSTATS AND MANUAL STARTERS. INSTALL ALL STARTERS AND
<br />CONTACTORS EXCEPT THOSE FURNISHED AS AN INTEGRAL PART OF THE EQUIPMENT.
<br />6. CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT NOT
<br />INSTALLED IN A PLENUM SPACE SHALL BE MADE WITH A SHORT LENGTH OF LIQUIDTIGHT
<br />FLEXIBLE CONDUIT, MINIMUM 18", INSTALLED IN A MANNER TO PERMIT MOVEMENT OF
<br />EQUIPMENT.
<br />7. PERFORM ALL EXCAVATING, BACKFILLING, CUTTING AND REPAIRING REQUIRED FOR
<br />INSTALLATION OF ELECTRICAL WORK.
<br />8. CONTRACTOR SHALL X-RAY FLOOR SLABS, WALLS, OR CEILING CONCRETE PRIOR TO ALL CORE
<br />DRILLINGS.
<br />N. CONDUIT: FEEDERS AND BRANCH CIRCUIT HOME RUNS SHALL BE CONSTRUCTED OF EMT WITH ALL
<br />STEEL RAINTIGHT OR SET -SCREW FITTINGS. CONNECTORS SHALL BE INSULATED THROAT TYPE.
<br />PROVIDE METALLIC BUSHINGS WITH PLASTIC INSERTS FOR 3" OR LARGER. CONDUITS FEEDING OR
<br />CONNECTING TO EQUIPMENT PROVIDED BY OTHER TRADES SHALL NOT BE INSTALLED UNTIL SUCH
<br />EQUIPMENT IS INSTALLED OR UNTIL SPECIFIC ROUGH -IN INSTRUCTIONS ARE PROVIDED BY THE TRADE
<br />PROVIDING THE EQUIPMENT. UNLESS OTHERWISE INDICATED, CONDUITS SHALL BE CONCEALED.
<br />RACEWAYS INSTALLED IN OR UNDER SLABS, ON GRADE, OR AS EXTERIOR DUCT BANKS SHALL BE PVC
<br />SCHEDULE 40 OR 80. RUN EXPOSED CONDUITS PARALLEL OR PERPENDICULAR TO STRUCTURAL
<br />ELEMENTS. TWO OR MORE RACEWAYS RUN TOGETHER SHALL BE INSTALLED ON GANG TRAPEZE TYPE
<br />HANGERS. SUCH RACEWAYS ASSEMBLIES SHALL BE RUN PARALLEL OR PERPENDICULAR TO
<br />STRUCTURAL ELEMENTS. CONDUITS EMBEDDED IN SLABS SHALL HAVE A MINIMUM OF 1" COVER OF
<br />CONCRETE ON ALL SIDES. OUTSIDE DIAMETER OF CONDUIT SHALL NOT EXCEED 1/3 OF THE SLAB
<br />THICKNESS. PROVIDE 0.25" NYLON PULL TAPE IN ALL EMPTY CONDUITS. BRANCH CIRCUITS MAY
<br />UTILIZE TYPE MC ARMORED CABLE ASSEMBLY WITH COPPER CONDUCTORS AND FULL SIZE
<br />EQUIPMENT GROUNDING CONDUCTORS FOR INDIVIDUAL DROPS TO DEVICES. TYPE MC CABLE SHALL
<br />BE SUPPORTED AT 48" INTERVALS AND SHALL NOT LAY ON THE CEILING GRID OR INTERFERE WITH THE
<br />REMOVAL OF CEILING.
<br />0. CONDUCTORS: ALL BUILDING WIRE SHALL BE 600 VOLT RATED THHN OR THWN COPPER, STRANDED
<br />0 SMALLER UNLESS APPLIED FOR CONTROL.
<br />FOR SIZES #8AWG AND LARGER, SOLID FOR SIZES 1 AND SMA L U O O
<br />ALL BUILDING WIRE AND SPECIAL CABLES FOR SYSTEMS SHALL BE INSTALLED IN A RACEWAY. ALL
<br />WIRE AND CABLE SHALL BE DELIVERED TO THE JOBSITE IN ORIGINAL UNBROKEN PACKAGES,
<br />CARTONS OR REELS, WITH THE MANUFACTURERS NAME, UL LABEL, AND CHARACTERISTICS OF THE
<br />PRODUCT PLAINLY VISIBLE. ALL WIRE AND CABLE SHALL BE MANUFACTURED IN THE UNITED STATES
<br />OF AMERICA. WIRES SHALL BE COLOR CODED AS FOLLOWS (A,B,C,N,G): 120/208-BLACK, RED, BLUE,
<br />WHITE, GREEN; 480/277 - BROWN, ORANGE, YELLOW, GRAY, GREEN. SPLICES SHALL BE COMPRESSION
<br />TYPE. CONTROL CONDUCTORS SHALL BE TERMINATED WITH INSULATED CONNECTORS, T&B STAKON.
<br />120 VOLT CIRCUITS WITH HOMERUN LENGTH OVER 125 FEET AND 277 VOLT CIRCUITS WITH A
<br />HOMERUN LENGTH OVER 250 FEET SHALL HAVE #10 MINIMUM HOMERUN CONDUCTORS. ALL THREE
<br />PHASE BRANCH CIRCUITS WITH A COMMON NEUTRAL SHALL HAVE #10 MINIMUM NEUTRAL.
<br />P. BOXES: OUTLET BOXES SHALL BE SHEET STEEL, MINIMUM 4" SQUARE, MINIMUM 1.5" DEEP, WITH
<br />PLASTER RING IN PLASTER OR BRICK CONSTRUCTION. OUTLETS BOXES IN POURED CONCRETE SHALL
<br />BE CONCRETE RINGS. MASONRY BOXES SHALL BE USED IN MASONRY OR TILE CONSTRUCTION.
<br />OUTLET BOXES FOR SURFACE ALUMINUM RACEWAY SHALL BE 4-11/16 WITH PLASTER RINGS
<br />ORIENTED HORIZONTALLY. BOXES SHALL BE SECURELY ANCHORED IN PLACE, AND SHALL BE
<br />SUPPORTED INDEPENDENT OF THE RACEWAY SYSTEM. PULL BOXES SHALL BE GALVANIZED SHEET
<br />STEEL, MINIMUM 12 GAUGE, WITH SCREW COVERS, AND WELDED CONSTRUCTION. WELDS SHALL BE
<br />COLD GALVANIZED. USING PERMANENT WATER PROOF VVIDE BLACK MARKER, CLEARLY LABEL COVER
<br />OF ALL BRANCH CIRCUIT JUNCTION AND PULL BOXES WITH PANEL AND CIRCUIT NUMBER OF CIRCUITS
<br />CONTAINED IN OR PASSING THROUGH THE BOX. BRANCH CIRCUIT AND FEEDER JUNCTION AND PULL
<br />BOXES USED WITH EMERGENCY FEEDERS AND CIRCUITS SHALL BE PAINTED RED. PROVIDE P-TOUCH
<br />OR DYMO LABELS ON COVER OF EACH FEEDER PULL OR JUNCTION BOX INDICATING FEEDER
<br />DESIGNATION, SOURCE, LOAD, AND VOLTAGE.
<br />Q. WIRING DEVICES: SWITCHES FOR LIGHTING CIRCUITS SHALL BE 120/277 VOLT, 20 AMP, A.C. ONLY,
<br />QUIET TYPE, WITH GROUND BONDING SCREW, SPECIFICATION GRADE. MOMENTARY CONTACT
<br />SWITCHES SHALL BE SINGLE POLE DOUBLE THROW, CENTER OFF GE #5935 OR EQUAL. DUPLEX
<br />RECEPTACLES SHALL BE 15 AMP HUBBELL 5262 OR EQUAL. DEDICATED DUPLEX RECEPTACLES SHALL
<br />BE ORANGE 20AMP HUBBELL IG5362 OR EQUAL. SPECIAL RECEPTACLES SHALL BE OF SIMILAR
<br />CONSTRUCTION. FACE PLATES SHALL BE SMOOTH NYLON OR THERMOSET PLASTIC. ADJACENT
<br />OUTLETS SHALL BE INSTALLED IN MULTI -GANG BOXES VVITH A SINGLE MULTI -GANG FACE PLATE.
<br />RECEPTACLES CONNECTED TO AN EMERGENCY CIRCUIT SHALL BE RED. COORDINATE COLOR OF
<br />DEVICES AND FACEPLATE WITH ARCHITECT.
<br />R. GROUNDING: ALL FEEDERS AND BRANCH CIRCUITS SHALL BE PROVIDED WITH INSULATED GREEN
<br />EQUIPMENT GROUNDING CONDUCTOR. CONDUIT GROUNDS ONLY ARE NOT PERMITTED,
<br />S. LIGHTING: SPARE FLUORESCENT LAMPS SHALL MATCH BUILDING STANDARD UNLESS OTHERWISE
<br />NOTED. INCANDESCENT LAMPS SHALL BE 130VOLT. NEW BALLASTS SHALL BE SOILD STATE
<br />ELECTRONIC. EXIT FIXTURES SHALL MATCH BUILDING STANDARD. FIXTURE LOCATIONS SHALL BE AS
<br />SHOWN ON THE REFLECTED CEILING PLAN. PROVIDE LAY -IN FIXTURES WITH TWO REMOVABLE CLIPS
<br />ATTACHING FIXTURE TO CEILING GRID. FLANGED FIXTURES SHOWN TO BE INSTALLED IN CONTINUOUS
<br />ROWS SHALL NOT HAVE INTERMEDIATE FLANGES. ALL PENDANT FIXTURES SHALL BE MOUNTED TO
<br />STRUCTURE. SEISMIC SUPPORT WIRES AND/OR COMPRESSION STRUTS FOR LAY -IN FIXTURES SHALL
<br />BE SUBJECT TO LOCAL AHJ LATEST REQUIREMENTS.
<br />T. FIRE ALARM DEVICES: NEW FIRE ALARM DEVICES SHALL BE COMPATIBLE VVITH EXISTING BUILDING
<br />ADDRESSABLE FIRE ALARM SYSTEM. INSTALL NEW DEVICES AND CONNECT TO NEAREST SIGNALING
<br />OR NOTIFICATION DEVICE CIRCUIT VVITHIN THE AREA. CONTRACTOR SHALL VERIFY CIRCUIT HAS
<br />CAPACITY FOR ADDED LOAD. SYSTEM SHALL BE CERTIFIED BY FIRE ALARM VENDOR AFTER
<br />COMPLETION OF WORK.
<br />U. PANELBOARDS: DEAD FRONT PANEL CONSTRUCTION WITH SEPARATELY MOUNTED INTERIOR TRIM.
<br />MAIN AND BRANCH DEVICES SHALL BE BOLT -ON. MULTI -POLE BREAKERS SHALL BE COMMON TRIP.
<br />WIDTH SHALL NOT EXCEED 22" FOR PANELBOARD AND ENCLOSURE SHALL MATCH BUILDING
<br />STANDARD. PROVIDE GROUND BUS IN PANELBOARD AND PROVIDE DEVICE MOUNTING HARDWARE
<br />WHERE A SPACE IS SCHEDULED. PANEL AND OCPD SHORT CIRCUIT RATINGS SHALL BE AT LEAST 10%
<br />GREATER THAN AVAILABLE SHORT CIRCUIT CURRENT AT PANELBOARD.
<br />V. DRY -TYPE TRANSFORMERS: TRANSFORMERS SHALL BE DRY -TYPE, ENCLOSED, SELF -COOLED,
<br />VENTILATED TYPE, DEAD -FRONT DRIP PROOF. PRIMARY AND SECONDARY TAPS SHALL BE ACCESSIBLE
<br />FROM THE FRONT. TRANSFORMERS SHALL MEET OR EXCEED BUILDING STANDARD TRANSFORMERS
<br />SPECIFICATIONS. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR IN THE PRIMARY FEED TO THE
<br />TRANSFORMER, SUPPLEMENTAL GROUND TO NEAREST ACCESSIBLE PRIMARY STRUCTURAL MEMBER
<br />OR EQUIPMENT ROOM GROUND BUS BAR. SIZE PER NEC AND RUN IN CONDUIT WITH BOND BUSHING AT
<br />EACH END. NEUTRAL AND GROUNDING CONDUCTOR SHALL BE BONDED TO ENCLOSURE.
<br />9
<br />U
<br />z
<br />c�
<br />Z� o
<br />r
<br />W
<br />Lo w
<br />a C�
<br />U ti � Z
<br />Cn w
<br />CC W U
<br />LL]
<br />I— UzU co
<br />v
<br />N�
<br />N �
<br />Cn
<br />z
<br />U)
<br />m
<br />p• G E N `g�"�tc'ji
<br />40 w
<br />N
<br />4tlF
<br />Z O RI %%
<br />� % ON AL
<br />16018
<br />0
<br />rn
<br />Q
<br />w
<br />Z
<br />w
<br />c>
<br />J
<br />m
<br />d
<br />Q
<br />U
<br />Z
<br />Q
<br />Q
<br />w
<br />Y
<br />Z
<br />cro
<br />w
<br />w
<br />J
<br />Q REVISION #2 11/16/2017
<br />CONTRACT DATE: 08.13.2017
<br />BUILDING TYPE: ONE-OFF
<br />PLAN VERSION:
<br />SITE NUMBER:
<br />STORE NUMBER:
<br />Restaurant Shell
<br />Zephyr Plaza
<br />ZEPHYRHILLS, FL
<br />ELECTRICAL
<br />GENERAL
<br />NOTES
<br />& LEGNED
<br />EO.0