Laserfiche WebLink
to <br />0 <br />N <br />m <br />02 <br />65'-0" <br />A D <br />S3 14) <br />H.B. <br />_ <br />I <br />_ <br />Oa)w 17'_ j' I <br />A <br />00 <br />r <br />o <br />OWNER'S SUITE B _ <br />8'-0" CLG. � <br />CARPET <br />0 <br />5-SH T <br />6 pp <br />---- R&S ---- <br />ir rn <br />BUILDER TO <br />N PROVIDE <br />W.H. APPLIANCE <br />p PROTECTION <br />2'_6" PER BC WHEN REQUIRED <br />2 CAR GARAGE <br />8'-0" CLG. 20'_Og„ <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I �,a <br />W.I.C. <br />8'-0" CLG. t� <br />CARPET L <br />T-8" <br />I <br />I <br />I <br />I <br />I <br />1. <br />$ <br />TIE <br />�- <br />- <br />- - <br />= <br />M0 <br />w <br />I <br />00 G <br />N S3 <br />64, <br />c <br />' <br />N <br />(4) 2x4 #2 SYP STUDS JFIBERG <br />W/ USP HTT4 @ BASE RROU <br />4'-0" <br />I �'� <br />io <br />FAMILY R M <br />I 9'4" CLG. <br />( CARPET <br />23'-0j" 0 <br />2668 <br />HANSON <br />BOX @ 36" <br />A.F.F. <br />DRYER VENT <br />THRU ROO <br />EDGE OF SLAB 2" <br />BEYOND WALLS <br />S3 <br />_ <br />1 <br />I/ 1 I <br />1 1 <br />IlxI <br />L <br />K (4) 2x4 #2 SYP <br />S3 STUDS <br />BASE <br />I cr <br />I 0 I <br />I O <br />I I 0 I <br />i O 2 i <br />I w I <br />I > t <br />I Or I <br />I I x I <br />I I <br />I I <br />NOTE: FINISHED I <br />WALLS TO BE I <br />I FLUSH. VERIFY IN I <br />FIELD. I <br />__-__ _____ <br />CC D <br />S3 G.T. - <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />o <br />�p <br />IT <br />o <br />- <br />TYP @ 1 STORY <br />A <br />O M <br />t�l <br />60"x36" <br />SHOWER <br />S <br />D <br />- <br />T1111 <br />---------- <br />&S <br />PT. W <br />OPT. D <br />HI <br />2:12 VAULTED CLG. _ <br />AHU <br />R.A.G. <br />_ <br />TILE <br />, <br />� <br />r <br />8 8 <br />7'-8" <br />- <br />T-10" <br />10'-101g„ <br />3068 <br />0,. <br />I <br />I <br />I <br />ENTRY <br />8 -0n CLG. <br />trc <br />9'4 <br />cL <br />in <br />, 6„ <br />11'-78' <br />I <br />6'-10" "' <br />-HDR AT 7'_4- <br />4'-0" <br />R&S <br />- <br />- <br />- _ R&S - - - - -„ <br />4'-78'-8" iv <br />------- <br />2668 ib°° <br />5'-4 " <br />14'-6" <br />= <br />2668 r <br />6 4" M <br />Am <br />N <br />I T-6" <br />0 <br />O <br />eo <br />I <br />o <br />I <br />PATIO CAFE <br />8'-0"CLG. <br />vi CARPET <br />E / I <br />O 0 <br />5068 B.F. <br />BEDROOM <br />8'-0"cLG. <br />CARPET <br />- <br />i? <br />10,�„ <br />M <br />2 <br />BEDROOM 3 <br />8'-0" CLG. <br />CARPET <br />10'-42" <br />00 _� z <br />ro <br />N _ <br />in CO J <br />I <br />I <br />2' 4' I <br />14068 B.F. <br />I <br />BEDR OM 4 <br />8'-0"ICLG. <br />CAI <br />11'-0' <br />o <br />'v <br />j j <br />I <br />OPT. <br />REF. I <br />g <br />P <br />r"D <br />- - <br />-- - <br />? <br />8 <br />U, <br />MU) <br />cow <br />MW O <br />/ <br />N <br />20'-6$" <br />W===; <br />Q J <br />U <br />- <br />_----___] <br />D.W. oa o� <br />'L _ ?' _ J 8 ' <br />„ <br />I <br />2 I „ <br />ILE <br />SI Kwl ISP <br />2,_ <br />5'- <br />-v <br />/ <br />00 <br />// / I � <br />/ I <br />"booI <br />1Y o w <br />vo <br />,n <br />16" DEEP <br />00 <br />06 <br />I <br />2" <br />I <br />o0 <br />TYP <br />1PANT <br />STORYNGF:= <br />A <br />TIE <br />■ <br />ZAD <br />AC <br />FIBERGLASS <br />SURROUND N <br />36 <br />----_ <br />O <br />O <br />-7 <br />H B� EGRESS EGRESS <br />A <br />OS3 O <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 j X 25 <br />S.H. <br />13 <br />20X38j <br />184X37i <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20X63 <br />18 X62 <br />S.H. <br />16 <br />20X72 <br />18 X71 <br />S.H. <br />432 <br />27 1/4 X 26 <br />26 X 25 � <br />S.H. <br />433 <br />27 114 X 38 <br />N/A <br />S.H. <br />34 <br />27 j X 501 <br />N/A <br />S.H. <br />33 <br />N/A <br />26 x 37 1 <br />S.H. <br />34 <br />N/A <br />26 x 50 <br />S.H. <br />435 <br />27 J X 63 <br />26 X 62 1/2 <br />S.H. <br />36 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37jX26 <br />36jX251/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 } X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 j X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 � <br />S.H. <br />33 <br />54 X 38 i <br />52 } X 37 i <br />S.H. <br />34 <br />54 X 50 j <br />52 j X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is Iocated.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swim Ing Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic , crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />(D <br />+28.3 / -36.4 <br />�E <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />GG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />11111i1111111111 - • • - <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "B 111 <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 24 <br />TOTAL AREA 2376 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 1 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />r' <br />CD <br />z o <br />z�z <br />Q <br />a <br />z <br />cc <br />N C9 <br />� <br />cn <br />.l...r w <br />O w <br />E <br />0' <br />� U <br />CD <br />m <br />N M <br />l..0 <br />W <br />C toLe �0 M <br />ooCD <br />_" <br />U83 <br />0 <br />Q o�i <br />�o-o <br />Q o <br />Al1 <br />B <br />D& <br />N�C�B•D�C <br />.,� B-D <br />� ►► il! / � <br />y,,,, G <br />N_. <br />rn <br />w, <br />' <br />/UUI <br />a� � rn � o � x <br />0 <br />= g li l w <br />'WHO- S O -".S <br />'15 o � ,`tip <br />UU1 lal3ESS1 d , <br />��Il11N11t� o <br />� <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />O <br />O <br />Z C*4 <br />0 � 11 <br />I/� M -+ O <br />„ M <br />Q U-) Ln <br />d cn •� '� <br />N U_ <br />CL <br />ce U a (o <br />a <br />E� <br />z <br />LULU <br />C:) <br />d• <br />.i <br />W� <br />za <br />2Q�U <br />MH <br />z <br />� 8 C J <br />T <br />U u� g <br />W <br />agoZ <br />L <br />^ <br />1.L <br />8 <br />� <br />cri <br />CcQ <br />Ce <br />Oa3 <br />M <br />L <br />�a <br />U <br />_ <br />LLLI <br />LU <br />o <br />a <br />F0 <br />8 <br />o � <br />0W <br />a6� <br />N <br />Q��� <br />Z <br />Z <br />OS <br />w <br />J <br />In <br />r-1 <br />aj <br />tii <br />U <br />N <br />Q <br />Z <br />W ~ <br />O <br />Zg <br />Z <br />COI <br />g <br />UJ <br />a <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: MJAMES <br />VERSION NO. 4s0 <br />SHEET NO. <br />1.0 <br />