My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3051 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3051 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:59:38 AM
Creation date
2/27/2025 1:04:48 PM
Metadata
Fields
Template:
Building Plans
Street #
3051
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19807
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VENT L 4' <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />T.O.M. 6'-0" SPECIFICATIONS <br />HDR HGT. <br />-- —---------------------------------— — — — — — — — — — — — — — — — — <br />1 ,-0" EXTENDED <br />OVERHANG TO TEXTURED <br />BE CENTERED CEMENTICIOUS <br />CD <br />ON DOOR FINISH ON C.M.U. <br />coon(TYP.) <br />14'-0" RIDGE VENT <br />!I <br />a <br />Co <br />E of <br />= 80 <br />REAR ELEVATION - 61 <br />SCALE: 1/4"=1'-0" <br />RIGHT ELEVATION - B1 <br />E: 1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified vdth Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO, IN. OF NET FREE AREA / SO. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />(Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed)172 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />L <br />Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />—Formula: (Sq. FL Soffit Needed) x 7 = (Sq. In. Needed) 186.25 = Amount of O'Hagin Vents Needed <br />m <br />z <br />z� <br />a <br />zcl <br />4--+ W <br />O W <br />� <br />5 M <br />CD <br />'- <br />U <br />W <br />m <br />�C., co <br />C t0 fM <br />O a N <br />_ <br />U <br />U-� <br />1O <br />Of <br />¢ rn <br />ur,Q <br />of a o <br />BID <br />\ <br />// <br />! J <br />' <br />• <br />N <br />l' <br />SE'' <br />z w <br />• J Z W <br />"Kip <br />� g z <br />91rrww <br />�•� C LL - dy <br />LL®��. <br />ESS1 <br />W a;a. <br />�"PAIIIw"' <br />El <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />z� <br />0 � n <br />I•%I U-) M O <br />z <br />M <br />Q V 'p In <br />a tn•�� <br />Un <br />H� C LL In <br />. <br />C, . <br />V Q C 00 �. <br />u <br />z § E <br />Z <br />W <br />Jz <br />oeo <br />VJ <br />'zoo <br />z <br />z <br />B <br />Q <br />gow <br />0 <br />W <br />CE <br />i® <br />L <br />0*1 <br />W <br />8 <br />LJ <br />0 <br />Z <br />�UJ <br />o <br />z <br />U <br />a <br />Q <br />Q� <br />LUJ <br />o <br />w <br />o96 <br />tY <br />Z <br />d^.oLUQ <br />.--1 <br />LL o <br />J <br />,Ln-t <br />W <br />W <br />E <br />Z U <br />N <br />Q <br />Z <br />Z <br />W~ <br />a $ <br />0 <br />NO <br />00 <br />Z <br />g <br />= <br />` w <br />r, <br />+-f <br />a <br />V) <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: M)AMES <br />VERSION NO. 4n0 <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.