My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3088 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3088 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:08:04 AM
Creation date
2/27/2025 1:05:00 PM
Metadata
Fields
Template:
Building Plans
Street #
3088
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
19809
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`v <br />it <br />2 <br />0 <br />iz <br />Go <br />N <br />M <br />---- - - - --I <br />^' ^ "" WEATHER <br />✓E BARRIER & <br />tARILY SECURE <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />WEATHER / `V <br />(- RESISITIVE <br />J1� BARRIER WOOD FRAME CONSTR. <br />TAPE EXTERIOR SELF -ADHERED FLASHING 3/4"-l" BEAD OF CONSTR. <br />3 SHEATHING BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN <br />I WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND <br />(A88EMalED WINDOW) OR EQUAL WEATHER PROOF CAULKING <br />2 O <br />Ir <br />O <br />O WEATHER SELF -ADHERED FLASHING <br />2 ' RESISITIVE <br />BARRIER SEAL TOPS OF JOISTS <br />UNDER DECKING 1 <br />(SEE DETAIL WP07) SUBFLOOR <br />SELF -ADHERED FLASHING <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under 1 1 <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head 2 2 <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW ■ SELF -ADHERED FLASHING FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER , EXTERIOR DOOR WITH DECK - SECTION AITA ■' <br />EXTERIOR SHEATHING <br />EXTERIOR SHEATHING 3/4"A' BEAD OF CONSTR. INSTALL SELF -ADHERED <br />,I ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD <br />THRESHOLD DOOR AND RETARD FLASHING, SEE <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING � X <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />E <br />AM <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />O <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />�O <br />L© <br />{ U SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING / 1 <br />2 <br />3" MIN <br />4 <br />ra.r,�rnrv�a r u1�n i i��a O 5 <br />SELF -ADHERED FLASHING F�m <br />SELF -ADHERED FLASHING ■ •FOUNDATION WEEP SCREED <br />DECK JOIST OUTSIDE CORNER I • <br />JIT <br />1 <br />icm) <br />RED FLASHING <br />%PER <br />,TH <br />0 <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER ■' <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />NEEDEDVSELF-ADHERED <br />RUBBERIZED ADHESIVE <br />THROUGASPHALT ADHESIVEFLASHINSELF-ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />0 <br />0 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-7 Ground 7 <br />0 <br />IO <br />RO <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shalt be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMANVDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as #Din each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />NOT USED ■ NOT USED ■ NOT USED ■ SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 .- <br />Z � <br />Z <br />Z <br />a <br />U, z <br />UM <br />M <br />W <br />C c0 <br />O <br />C� <br />CD <br />¢ <br />Q <br />N C H D C <br />Z M Z <br />IIae oCD <br />W <br />�W � j a <br />pa�W z <br />Z m� �m <br />W m <br />m^� <br />LLOZ CP <br />V a N J G <br />W N <br />o o <br />C.3 <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z C4 <br />0 a)N <br />� M O <br />M <br />M Lr) <br />Z <br />(1)O L^ <br />< C U_ <br />Q 0000 <br />Z E <br />§ ra <br />Z <br />WJ <br />C) <br />OOED <br />2 Z <br />/n <br />�W <br />N <br />� <br />8�� <br />N <br />Q <br />g� <br />LLI <br />W <br />LL <br />O <br />a <br />O <br />C <br />LU <br />O n' <br />Ja <br />�0� <br />t�0uJg <br />DC <br />Z <br />Z <br />J <br />� <br />Ln <br />�-4 <br />di <br />Z <br />�z <br />0 <br />In ZW <br />O <br />N <br />0o <br />Z <br />:5= <br />�Z�- <br />tuu <br />T--1 <br />0- <br />1 to <br />SCALE : AS NOTED <br />DATE : 3/19/2018 <br />TECH: MJAM ES <br />VERSION NO. 4mO <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.