Laserfiche WebLink
ao <br />!-;z <br />e_ <br />00 <br />T.O.M. _ <br />HDR HGT. <br />------------------- <br />o TEXTURED <br />C? CEMENTICIOUS <br />i FINISH ON C.M.U. <br />(TYP.) <br />12 12 <br />5� �5 <br />--------------- FM7 <br />EXTENDED <br />OVERHANG TO BE10 <br />CENTERED ON DOOR <br />25 SH 25 SH <br />F.FL. _ _ _ _ 506GD <br />8 - <br />12 <br />5� <br />-- — — ------------------------------------------ <br />1'-0" <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />0" RIDGE VENT <br />12 <br />�5 <br />1 <br />4'-0" RIDGE VENT <br />12 <br />zz:�5 <br />REAR ELEVATION - Al <br />HEEL <br />�5 iv <br />T.O.M. , <br />----------------------- --- <br />--------------------------------------------------------- 21-011 <br />HDR HGT. <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. co 00 <br />(TYP.) �p <br />35SH <br />----------- ]-L----F.FL. <br />----------------------------------------------------------------------------------------- ------------------ <br />SCALE: 1 /4"=V-0" <br />LEFT ELEVATION - Al <br />- <br />1/4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or comice vents. <br />"CALCULATIONS BASED ON THE FOLLOIMNG VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 $0. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Dock -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />"Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of allagin Vents Needed <br />V <br />z_a <br />z�z <br />a <br />N 0 <br />a) <br />cn <br />4--+ W <br />M o <br />O c <br />E <br />LUW <br />® 1--- <br />tD M <br />C"! <br />O <br />U <br />U. <br />fO <br />Q rn <br />9 < 8 <br />tiii!!f <br />A <br />B D..�`- <br />N•C• <br />• � �" Qom' <br />�',z,—Ku <br />�• <br />Z• FED' <br />►0l. <br />4f <br />W N <br />21 CE <br />U <br />U <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z NC <br />0 � N <br />> 15 <br />ILn <br />in O <br />Q 'gyp Ln <br />N LL Ln <br />L- .Y. <br />Q , <br />E <br />W <br />Z <br />J <br />J <br />Z <br />w� <br />z¢a <br />CQ <br />f <br />oo <br />z <br />O <br />VU <br />g�w <br />Z <br />O W <br />U�iV4 <br />LLU <br />o <br />L.LJ <br />�UJI Z <br />0 <br />0 <br />LZ <br />O <br />,0 <br />= <br />z <br />Q <br />< <br />W� <br />�• M t '� <br />r-4 <br />�0 <br />O -C <br />aaCe <br />Q <br />z <br />W <br />,- <br />Ln <br />LLi <br />(a <br />'J <br />r-4I <br />LUz <br />Q <br />z <br />u <br />Ln <br />N <br />r <br />00 <br />z <br />QQ <br />a <br />W <br />° <br />z <br />rn <br />SCALE : AS NOTED <br />DATE : 3/19/2018 <br />TECH: MJAMES <br />VERSION NO. 4 . O <br />SHEET NO. <br />3.2 <br />