ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />MAIN <br />0 <br />200 amp <br />150 amp <br />14EMA 1 <br />2DO AMP <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copperto WH <br />#10-3 copper to Dryer <br />or 4/0 SER Alu <br />I POWER CO. FEED <br />I <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />j TERMINATION PER 5P WITH CODE APPROVED <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />-----------------------------------------------' <br />GENERAL ELECTRICAL NOTES ■ ■ Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) kitchen 44" AFF VERIFY METER LOCATION <br />bathroom 39" AFF H.B. <br />WITH BUILDER <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF ( — <br />2. All trim plates & devices to be ganged, where possible. AC PAD -------------------- <br />3. Electrical switches to be at 42" centerline above finished floor. ' -� n I ` <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the ' B E D R�OO M 2 ( B E D00 M <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the I ROUGH -IN FOR ROUGH -IN FOR <br />installation & sizing of all electrical, wiring & accessories. DISC. w " ' ' I.C. ' I OPT. CLG. FAN/ OPT. CLG. FAN/ <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. / I LIGHT PRE-WIRI\ 12\ I LIGHT PRE -WIRE <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the WP ROUGH -IN FOR <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. GFI OPT. CLG. I�AN/ !r I OM 4 <br />dete <br />7. Provide Tamper Resistant Receptacles as required by the NEC, 406.11---------------LIGHT PRE-W N/ �8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling ��D[ <br />�/ <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and qP <br />`• • • \ I / I <br />vapor detector sensor, according to the installation. \ \ <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and - / <br />S.D S. <br />labeled by a Nationally Recognized Testing Laboratory. I <br />10. Keep all smoke detectors minimum of 36" from bathroom doors GFI M <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. I DEDICATED RECEPTACLE <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits ROUGH -IN FOR D FOR MICROWAVE RANGE <br />is not acceptable. I OPT. CLG. FAN/ HOOD PER SPECS�HALL <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an I LIGHT PRE -WIRE <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and _- - - - - - - - --. <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />, C.M <br />when the door or window are opened..UU AM W UU <br />Tr <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed ,CaEI--- _ G�� FI �a 44" <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing OWIVGR G I Z J A.F.F. <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill ` \ RAG O w r - _ - - - - - - - <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the SUITE F- Q <br />spacing of the outlets unless the distance from the sink or range is greater the 12 for straight counter _ Q a I <br />tops and 18" for sinks and ranges installed in corner counters. _ �KI E — n _ I <br />-I ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />FE�W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />y <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />g <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />� <br />220 VOLT OUTLET <br />N <br />N <br />WALL SWITCH <br />THREE-WAY SWITCH <br />a <br />�4 <br />FOUR-WAY SWITCH <br />R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />g <br />WALL MOUNTED LIGHT FIXTURE <br />J <br />O <br />RECESSED LIGHT FIXTURE <br />N <br />04 <br />LIGHT FIXTURE WITH PULL CHAIN <br />c <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />3 <br />;Q� <br />EXHAUST FAN/LIGHT COMBINATION <br />Q <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />w <br />i <br />CH <br />CHIMES (OPTIONAL) <br />S <br />E <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />oSD <br />SMOKE DETECTOR <br />`o <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />c <br />TELEPHONE (OPTIONAL) <br />t` <br />® <br />TELEVISION (OPTIONAL) <br />0 <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />i <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />°O <br />® <br />SPEAKER (OPTIONAL) <br />N <br />^ ^ <br />i( <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />� <br />J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />ENTRY <br />MAIN ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />(9 <br />Z tTj <br />z <br />a <br />U) z <br />�V^1)' (9 <br />� w <br />O c <br />E <br />o <br />�V7 <br />U' <br />M <br />VIPw <br />� <br />O O <br />■� <br />_ ■1 <br />U N <br />p" <br />tJ.. OD <br />Q,o <br />f�y o <br />B D. <br />F <br />' / <br />N � N <br />m ( <br />V d YY Z U) Z 1; z <br />Z W o J <br />W l.L <br />W a <br />ru <br />CkZ� < <br />m R8 <br />LLZ �8r6 mm <br />� <br />W <br />Na iX Oppp� <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1t <br />0 <br />0 <br />Z cV <br />OIL <br />►>-, M O <br />M <br />a�vLn <br />Q U_ <br />ZZDC <br />3 Q00 <br />Q � <br />Z M <br />W <br />W� <br />Za <br />ty ti <br />V <br />41,0 <br />ca W <br />Z <br />W <br />Y�Z <br />I1 0 uJ <br />O'�JfLi25 <br />Z <br />U W <br />W <br />a- <br />pF <br />U <br />to 3 <br />UOU <br />= <br />LU <br />W <br />W <br />o <br />��Na <br />gV <br />0' <br />J <br />.E, <br />N <br />Q <br />u <br />Z <br />W <br />rl <br />Ln <br />Uj <br />Q <br />Z <br />ZV <br />W$ <br />N <br />p <br />Z <br />11 <br />m <br />O <br />o <br />rn <br />,--I <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 3/19/2018 <br />TECH: MJAM ES <br />VERSION N` 4mO <br />SHEET NO. <br />4.0 <br />