Laserfiche WebLink
<D <br />LO <br />g <br />C" <br />N <br />a <br />u7 <br />r` <br />CV <br />(D <br />c <br />X) <br />0 <br />F1 <br />CV <br />a <br />00 <br />N <br />E <br />1% <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94---/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Doper to lights & outlets <br />Dpper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />I Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FPP <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />FC..,.�...... <br />ELECTRIC DOOR OPERATOR (OPTIONAL) SYSTEM <br />CH I CHIMES (OPTIONAL) <br />O PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />owl ELECTRIC PANEL <br />i <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c/> <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />I <br />I <br />I <br />I <br />I <br />I <br />i <br />I <br />nnI <br />UPPER ELECTRICAL PLAN <br />SCALE: %4=V-0" <br />u, <br />U <br />z <br />z�z <br />Q <br />a <br />U) z0 <br />V) 0 <br />rn <br />w <br />t� <br />�U — <br />O w <br />C <br />E <br />o 0 <br />U <br />E <br />x — S <br />( cM Cl) <br />O M N : <br />0 oQ. <br />Unao <br />Qm <br />� s. v <br />a<C5 <br />D Do <br />� <br />� N <br />N <br />� N <br />CD <br />9AZP 4 m <br />Z <br />z °D <br />z <br />N LL T� <br />w U <br />2 <br />Lis_ <br />W=moo <br />�M <br />a Uj <br />d <br />_ 0 m d 4 a <br />CC <br />o <br />N <br />�Z a E <br />Z <br />QQ <br />m m <br />¢ CM <br />W ! �s <br />d C <br />v <br />C> <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />� <br />O cu <br />o <br />M <br />p/ZI <br />V) ro Ln <br />� Ln <br />ZH <br />a� M <br />QC U CL <br />00 <br />< <br />� <br />W <br />Z � <br />wo <br />J O <br />11.0 <br />�z <br />�CC <br />Q <br />eY <br />za <br />Z <br />fF- <br />F <br />X <br />Q <br />w¢ <br />�Z80 <br />J <br />Zw-IX <br />�ouzj� z <br />J <br />LU <br />£ Lo <br />W <br />E <br />04 <br />E— <br />Zz <br />}o <br />W <br />2:z <br />� <br />i <br />� <br />to <br />w <br />L <br />p <br />�< <br />a <br />w <br />0 <br />_ <br />(V <br />goo <br />�- `�ILL. <br />TV <br />0 0 <br />C) <br />z <br />X O U <br />w O �-y <br />�Qi <br />O <br />N <br />Q <br />O <br />L{� <br />Q w of <br />8�u 2:0 <br />Z��C <br />Z <br />LU <br />Ln <br />W <br />di <br />a LL <br />N~gz8 <br />U <br />N <br />Q <br />Z <br />waZ <br />Z <br />*k <br />N <br />Z <br />R Z <br />0 <br />0o <br />g <br />= <br />a uj <br />z <br />n <br />,--I <br />d <br />u) <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO. 5ol <br />SHEET NO. <br />4.1 <br />