ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights 8 outlets <br />HEMA 1 <br />200 AMP <br />01 #12 copper to 20 amp ckts <br />10 #10-2 copperto WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O <br />2/0 or 4/0 <br />SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />I HALF -SWITCHED DUPLEX OUTLET <br />I Ph SPECIAL PURPOSE OUTLET <br />VIM <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />Tq 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />D9 <br />ELECTRIC METER <br />ffin <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />613 <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H <br />(I� i U �� IRRIGATION <br />VP j'---- (� ---, VERIFY LOCATION I GFI @ 44" A.F.F. <br />, n'. I. C. <br />i W H ELECTRICAL PANEL <br />V V l� I O <br />00, <br />I <br />I I <br />' \\ -- — <br />OWNER S SUITE 2 CAR GARAGE <br />1 I I <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ I \T-1-77 <br />j GARAGE GFI FOR <br />GAR. DOOR 1 <br />LIGHT PRE -WIRE _ I LIGHT AS PREWIRE <br />i I PER SPECS I <br />GFI @ 44" 1 <br />G-----------J A.F.F. <br />T02_N_D <br />�\ \ OPt. D <br />GFI@4411 - / <br />A.F.F. L------------ <br />S.D C.M -- -- - - / GFI @ 44"WP O / 1 1 1j ----- 16 - - - - A.F.F. <br />GFI ------- <br />3 ' CH - - - - - 11 3 <br />PATIO I C.M <br />I DEDICATED RECEPTACLE <br />/ FOR MICROWAVE RANGE j <br />I HOOD PER SPECS / <br />U.C. SWITCH <br />FI FOR DISPOSAL <br />..... If <br />i. <br />t, \ FAMILY RM / / <br />CAFE GFI,; 1 - <br />/ FLEX <br />I C <br />I G �/ PENDANT AS jl D.W. I \ <br />ROUGH -IN FOR I I II19 <br />OPT. CLG. FAN/ PER SPECS \ C _ �— J I PANTRY \ `! <br />. ;C <br />I LIGHT PRE -WIRE / \ WP VGFII -- G J <br />GFI =0 <br />/ - - <br />4 1 / oo \� — ROUGH -IN FOR <br />00 OPT. CLG. FAN/ <br />DISC. 4 1 / / \ LIGHT PRE -WIRE - <br />/ OPT. REF. <br />AC PAD AC PAD --- GFI - ------ ----GFIdb <br />WP I <br />GFI I <br />GHTIAS <br />jGFI <br />J <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />0 <br />_: <br />� N <br />z <br />QQQ <br />Q <br />a <br />W <br />W � <br />4--J ly <br />Q <br />DU — <br />-( O c <br />.12 <br />e <br />In <br />U <br />U <br />o <br />m CN <br />CN <br />L.L <br />' ~ <br />dM <br />C Cn <br />tD 2 <br />O O N <br />U <br />L LL 00 <br />AYE <br />0 <br />Q l7l <br />O� O <br />ro N <br />Z y o <br />z <br />LL Z <br />H N <br />�� <br />Ci- <br />W — of C u <br />W Q D�� <br />d <br />z <br />_ 4¢ �� <br />M� 6 <br />o 0 <br />m coZ <br />Z <br />LL W Na <br />a M <br />0 <br />O <br />O U <br />❑❑ <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 5th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z N <br />O � N <br />CD <br />u>-+HMO <br />fM <br />Q�'p170 <br />o- to •L, d- <br />QLL <br />Z <br />� v fa <br />CL 00 <br />Q <br />Z E ­-0 <br />W <br />J � <br />1 Z <br />.1 <br />Z Qa <br />f� <br />F- <br />Z <br />wa�� <br />O ce U <br />z <br />U, <br />(71 <br />U <br />w <br />o LWL u. <br />WM <br />"gu <br />W <br />Z <br />� <br />N <br />I— <br />Z <br />0 <br />w <br />Lr) <br />J <br />LJJ <br />c <br />U <br />_ <br />i <br />O <br />�uj <br />(� <br />O <br />J <br />ILL <br />oI <br />ILpo <br />o <br />a <br />AYp <br />za <br />a3 <br />Z <br />.--1 <br />0 <br />� U. LL <br />a� <br />J <br />Ln <br />LJ.I <br />Z <br />UJI <br />Q <br />a l <br />Z U <br />w�� <br />M <br />N <br />N <br />Q <br />Z <br />Z <br />�IS <br />90 <br />m <br />� <br />00 <br />� <br />U <br />2 <br />9 <br />,--i <br />a <br />V) <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION N0. 10 <br />SHEET NO. <br />4.0 <br />