Laserfiche WebLink
0 <br />M <br />N <br />00 <br />i <br />a <br />•�i <br />v <br />0 <br />J <br />M <br />N <br />� J ■ <br />1 <br />CARPET <br />O fn <br />w <br />N (� <br />W <br />A <br />S3 <br />TYP @ 1 STORY <br />I <br />OWN R'S� <br />SUIT <br />8'-0" FLAT qLG. <br />CARPE - <br />I <br />(4) 2x4 #2 SYP 17G <br />STUDS W/ USP S3 <br />HTT4@ BASE <br />ilrl• O <br />II IIIIIC�IIIIIIIChi711111 <br />BEDROOM 2 <br />8'-0" FLAT CLG. <br />CARPET <br />1 mom <br />O <br />25-SH <br />EGRESS <br />BEDROOM <br />8'-0" FLAT CLG. <br />ao <br />I CARPET <br />CD <br />0 <br />v <br />�■ ■i <br />II1.: B.F.FIBERGLASS <br />SURR UN <br />I)1WTL24 <br />• 1 <br />.�SHLL <br />• <br />CARPET <br />v �I■ <br />Iri-Nw.u. <br />1110 <br />AWN ■■■1■■ ��► � �lil <br />�1 1®■0I <br />11CIM60 <br />E A4 Him% <br />Nit-- MI. 0 1 "Mm 2 0-" <br />�00 <br />III■ I . <br />• a ■, • <br />ON, SURROUND <br />iO <br />•- <br />5'-01, 1 `'1a G HA SC N BOX @ <br />33 36' A.F F. <br />9'-0" I 3'-8" 2'-8" 4'-3" 6'-10" 3'-7" <br />I <br />I I <br />9.12 SLOPE . I to <br />CEILING <br />00 <br />� I <br />I• t ) C6 J- <br />00 <br />PATIO � YI <br />1.749 Cl) <br />FAMILY ROOM <br />4'-0' // VAULT. CLG. CAFE <br />CARPET ^^ ^- VAULT CLG. <br />S3 <br />35-SH <br />0 <br />to <br />— R&S <br />��,,��t �-M� <br />�Iii ro <br />H.B. <br />IN <br />I <br />BEDROO 4 <br />V-0" FLAT CLQ. <br />CARPET i <br />X-0" Sf-� <br />I I <br />CT <br />TwT740681B.F. <br />8'-0" <br />t14 R&S C' G.T. <br />KF — — — — — — — — — — - <br />S3 I D <br />I I 1 S3 <br />H � H <br />2-CAR GARAGE <br />I <br />3 8'-0" FLAT CLG. j <br />I <br />EDGE OF SLAB 2" I I I <br />BEYOND WALL <br />DRYER VENT <br />THRU ROOF <br />20'-9" I I <br />I <br />I <br />I <br />I A <br />I l l 1 I <br />INI� I I <br />I�Q�I <br />I <br />III 11 I I <br />I <br />L----t -------- <br />I I <br />I <br />3068 I I <br />OI <br />B <br />ENTRY <br />°Q I <br />I 8'-0" FLAT CLG. <br />V-4" <br />15'-0" <br />2 <br />rn fn <br />w ,n = <br />oC cw) O o0 <br />O � <br />w •- <br />/ A \ <br />NCO] <br />0 <br />b <br />N <br />to <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 91 /4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 71 /4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18}X25 <br />S.H. <br />13 <br />20X38j <br />18}X37i <br />S.H. <br />14 <br />20 X 50 j <br />18 J X 50 <br />S.H. <br />15 <br />20X63 <br />18}X62j <br />S.H. <br />16 <br />20X72 <br />18JX714 <br />S.H. <br />j 32 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />433 <br />27 1/4 X 38 <br />N/A <br />S.H. <br />} 34 <br />27 I X 50 <br />N/A <br />S.H. <br />} 33 <br />N/A <br />26 x 37 <br />S.H. <br />434 <br />N/A <br />26 x 50 <br />S.H. <br />435 <br />274 X 63 <br />26 X 62 1/2 <br />S.H. <br />j 36 <br />27 4 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 } X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 4 X 50 <br />S.H. <br />25 <br />37 1 X 63 <br />36 X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 � <br />S.H. <br />33 <br />54 X 38 j <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 } X 71 } <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is kocated.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />DA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />�E <br />+26.6 / -28.0 <br />�F <br />+26.6 / -32.2 <br />GC� <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ 9'-4" A.F.F. <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA <br />1817 <br />LIVING TOTAL <br />1817 <br />GARAGE <br />427 <br />FRONT ENTRY <br />32 <br />TOTAL AREA <br />2276 <br />tL <br />INSULATION REQ. <br />0O <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />M <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />``' <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />�, <br />C9 <br />zo <br />z <br />z <br />Q <br />U) z <br />V) (9 <br />Q) <br />v3 <br />i---r w <br />O <br />`E <br />C) <br />LU <br />M <br />W ® ~ <br />t0 C-, <br />_ N <br />_ <br />U <br />s 00 <br />� <br />< = <br />L o <br />9 < 6 <br />A 1 <br />B D. <br />` —;: <br />k <br />as <br />Z• <br />Ur <br />�l ^ .L <br />u..�.� <br />W 1. <br />c <br />To the best of the Engineer's knowl6dgej IrtfUrniation,and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />O <br />z <br />On <br />M O <br />M <br />¢ (n "M Ln <br />d- <br />Q U_ <br />z <br />a/ 3- Q 00 <br />¢ � <br />z E <br />WJ <br />ko <br />W <br />za <br />FLU <br />W <br />z W <br />Z <br />uc-,8 <br />T <br />O <br />Z <br />V ' <br />ILL. <br />_n <br />0 <br />W <br />C <br />0 <br />_ <br />T <br />gg� <br />[i <br />05 <br />r-4 <br />41E <br />DC <br />�U4 a�:j <br /><au,ce <br />ZP <br />LnLLJ <br />J <br />¢ <br />z <br />LU <br />Z <br />o <br />Luigi <br />I <br />M—i <br />N <br />m <br />O <br />06 <br />Z <br />g <br />LIJ <br />f <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAMES <br />VERSION NO. 4n0 <br />SHEET NO. <br />1.0 <br />