My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3124 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3124 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:57:32 AM
Creation date
2/27/2025 1:06:04 PM
Metadata
Fields
Template:
Building Plans
Street #
3124
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
19806
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tp <br />m <br />tcn <br />r` <br />LO <br />N <br />it <br />c <br />v <br />x <br />0 <br />J <br />N <br />N <br />tR <br />E I <br />E <br />0 <br />x <br />�21 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 -/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />upper to lights & outlets <br />upper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Alu <br />----------------------------------------------- . <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FPP <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />R4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />;Q, <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />T <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />mpg_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />89 <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />DISC <br />GFI ; 'WGFI %FI- <br />F----- <br />..�..� REF. <br />KITC <br />HENG F6 _____-- - <br />- - Li 1TGFI U - <br />0 <br />io <br />DINING ROOM <br />/PENDANT AS <br />/ PER SPECS <br />M <br />M. <br />ROUGH -IN FOR C / <br />OPT. CLG. FAN/ / <br />LIGHT PRE -WIRED <br />FAMILY ROOM <br />INII <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />VERIFY LOCATION IRRIGATION <br />ELECTRICAL PANEL <br />I <br />I <br />I <br />_ _ I <br />/ � I <br />/ � I <br />\ I <br />I <br />\ \ I <br />I <br />GFI FOR I <br />GFI @ 44" GAR. DOOR <br />A.F.F. GFI <br />I <br />� I <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OL ------------ <br />GFI @ 44" <br />E <br />W.H. 'A.F.F. <br />r GFI <br />RI FLEX <br />TO 2N_D <br />FI FLR. <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ 7f <br />----- LIGHT PRE -WIRE <br />a <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />zC <br />— O <br />Z <br />Z <br />Q <br />U) z <br />V) <br />0� <br />n' <br />w <br />OLL' <br />Lv <br />o 0 <br />U <br />W <br />t F— 8 <br />a) C', <br />co <br />C t0 co <br />O <br />_ <br />o <br />co <br />- tL 0 <br />co <br />is <br />05-&o <br />S.v <br />do¢o <br />B D. <br />N` <br />Ir— <br />O <br />� N <br />42 O O O <br />N_ <br />N <br />o <br />CZ <br />� . _ 8 <br />EA Z M <br />J O <br />z <br />J <br />0: �LLNo <br />-a.. <br />w" <br />aw <br />�W <br />ZtiQa s <br />z <br />0��� <br />E <br />CDelf <br />m m <br />Z 0CD <br />, <br />< <br />d � <br />W CN <br />N � � <br />U <br />Qo <br />V <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />BuildingCode - Residential 6th Edition. Engineer's <br />B <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />O <br />Z N <br />0 v <br />h.I--I <br />1J O <br />> M 00 <br />M <br />Q 'fO In <br />�t <br />a toZ V) 0 N <br />r C U_ <br />CL ^ <br />U a oQ <br />u <br />Z ra <br />Z C:) <br />W <br />t0 <br />�z <br />u <br />Zg <br />f< <br />Z <br />w¢a,tL <br />U Z_ OV O <br />OOa'O <br />W <br />J <br />F�U.Z <br />�ZfW <br />Q <br />L <br />� <br />w <br />OZ <br />} p <br />V / <br />b <br />YZ <br />OR <br />W <br />a <br />N <br />_ <br />oW <br />N <br />oc <br />U <br />= <br />�Z <br />LL <br />L9 <br />0 <br />XO�gU <br />Q <br />o<oa <br />Z W Z J <br />daZ3wrr <br />Q <br />X0 <br />Z <br />T-4 <br />�Cvt5 <br />¢�� <br />J <br />� <br />E <br />Q <br />LV <br />QF� <br />Z <br />o <br />a Z <br />fV <br />Z <br />�.. <br />�� <br />RZ <br />00 <br />Z <br />w <br />z <br />O <br />00 <br />g <br />V <br />,--t <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION NO. 5al <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.