My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3136 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3136 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:06:32 AM
Creation date
2/27/2025 1:06:19 PM
Metadata
Fields
Template:
Building Plans
Street #
3136
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
19977
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />WEATHER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />(ASSEMBLED WMDGW ) <br />2 �- WEATHER <br />s RESISITIVE <br />BARRIER SEAL TOPS OF JOI; <br />UNDER DECKING <br />SELF -ADHERED FLASHING (SEE DETAIL WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN ---, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - X <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />NAILING FLANGE <br />1�4 <br />SELF -ADHERED FLASHING <br />�o <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"A" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />IM <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />la <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />Q <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF <br />NEEDED IN CORNERS <br />THROUGH SELF -ADHERED <br />FLASHING <br />Fez <br />�o <br />RUBBERIZED RUBBERIZED ASPHALT <br />ASPHALT ADHESIVE ADHESIVE <br />SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />Ground <br />[O� <br />Water Resistant Barrier <br />rn <br />Lath <br />SELF -ADHERED FLASHING <br />Sheathing g <br />CD <br />Stucco <br />d <br />AN <br />d. <br />in <br />DOGBLE <br />_InI <br />SINGLE WOOD BEAM <br />JOIST BELOW SELF -ADHERED FLASHING <br />N SELF -ADHERED F>LASHING 1 <br />N <br />i 3" MIN 2 <br />E5 SELF -ADHERED SELF -ADHERED 4 <br />¢ FLASHING FLASHING <br />Q 5 <br />SELF -ADHERED FLASHING W SELF -ADHERED FLASHING W • DECK JOIST , OUTSIDE CORNER FOUNDATION WEEP SCREED ' • , <br />v <br />LO <br />N <br />F- I 00 <br />�I <br />0 <br />x <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1 /2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />\'"=--a"E"A <br />\2. <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />NOT USED NOT USED NOT USED SCALE: NOT TO SCALE im P, ft e <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside comer will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />ul <br />0 <br />Z a <br />Z <br />Z <br />Q <br />a <br />Z0 <br />t/) 0 <br />Q) rn <br />"I--J L.0 <br />O LU <br />E <br />51 <br />t�ZD <br />I_ <br />U <br />ii o <br />m <br />Np� M <br />W <br />' E <br />- $ <br />C f0 M <br />Lovch <br />O o0 <br />_" <br />o <br />0 �1::- <br />(--.6 <br />L �- <br />Q Ci <br />B Vv <br />co <br />C <br />N <br />N_ <br />� N <br />o <br />p <br />p N Q M <br />Z <br />d <br />Z O <br />Z <br />= � di f•N'] O <br />W 4 � � <br />Z <br />W LL <br />W <br />_ <br />03W V <br />z <br />U) CD <br />YN l0 <br />W IM < pf <br />W Nam <br />[m] <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />9 <br />0 <br />0 <br />Z N <br />�l� <br />O-f <br />19 <br />14 CD <br />Z <br />> (/) M O <br />M <br />Q - In <br />0. to .L �- <br />0 <br />Q �LL� <br />CL <br />OC U <br />Q <br />E <br />Z C <br />W <br />J� <br />'Cr <br />J <br />oZ <br />Za <br />�p <br />400 <br />c <br />U <br />Z <br />g�W <br />J <br />8��$ <br />L <br />N <br />ZIN <br />Z <br />LLJ <br />0 <br />oC <br />LL <br />O <br />� <br />p <br />N <br />rl <br />0 <br />;a <br />U <br />=W <br />W <br />0cc I� <br />0 <br />J <br />QUY P <br />X UQJ 6 <br />N <br />3;:�aiY <br />U mm <br />o <br />a <br />d- <br />x: <br />Z <br />Z <br />Z <br />a <br />,o�Z <br />J <br />rl <br />I <br />Q <br />LJJ <br />Z <br />Z U <br />$Wv <br />~ W 2 <br />N <br />N <br />Z <br />m <br />O <br />[ <br />�"+ <br />z4 <br />J <br />Lu <br />a <br />W <br />rn <br />,--I <br />a <br />cn <br />f <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: M.IAMES <br />VERSION NO. 4nO <br />SHEET NO. <br />WP <br />
The URL can be used to link to this page
Your browser does not support the video tag.