Laserfiche WebLink
O U) <br />N (� <br />uJ <br />A <br />S3 <br />TYP @ 1 STORY <br />o <br />= <br />A <br />N <br />fl- <br />`q <br />LO <br />N <br />aGi 17 <br />to O CID <br />CD <br />$I I I IPATIO " <br />1 1 -1 4'-0" <br />H.B. <br />R&S —L_— <br />W.I.C. <br />8'-0" FLAT CLG. <br />CARPET <br />— — — — — — — — — — — — — — — <br />R&S 1 <br />12' 8" <br />I <br />S3 <br />4-SH <br />BEDROOM 2 <br />8'-0" FLAT CLG. <br />CARPET <br />• -) Jt,W <br />•.: % 1 <br />• • : it'd � /�eo� <br />O <br />25-SH <br />O <br />25-SH <br />EGRESS <br />I <br />EGRESS 1 <br />I <br />I <br />BEDROOM <br />8'-0" FLAT CLG. <br />I CARPET <br />Cal <br />�Ico <br />� <br />t <br />CV7 4068 B.F. <br />(D FIBERV-3q" T-8y" <br />SURR= <br />60" X _ _------------- SHOR&S <br />CCDCD"'66' <br />N <br />HALL <br />9'-4" FLAT CLG <br />CARPET <br />- � <br />SUIT <br />1 <br />...EJ <br />■mil <br />i � � <br />Min <br />M <br />�1�i <br />O <br />is • i. <br />■�IIIIIII 1 <br />RIK <br />■ <br />_ <br />•: " <br />I' <br />N, <br />i� <br />` <br />l <br />1 <br />(4) 2x4 #2 SYP G - <br />STUDS W/USP S3 I <br />HTT4@ BASE I� u I D.W. I as <br />0w� L___J00 <br />-----T--- o �� FIBERGLASS <br />1 <br />CM 1 I SURROUND <br />LJ �— <br />5'-0" V-`rs1" I G HAS N BOX @ <br />S3 36' A.F F. -- — R&S- <br />9'-0" 1 T-8" 2'-8" 4'4- 6-10" T-7" OPT. OPT. D <br />0 <br />1 -0" LA CL' . <br />2-12 SLOPE-) <br />CEILING I _ 4r <br />I 868 <br />I I <br />- ------------------------------------ <br />�� <br />Q <br />COFAMILY ROOM <br />_ <br />VAULT. CLG. CAFE <br />i� CARPET VAULT. CLG. <br />A <br />S3 <br />37-8" <br />L <br />35-SH <br />O H.B. <br />1 <br />I <br />3' <br />I <br />0 <br />4'-1" l'-3" <br />8'-01� <br />L668 �N <br />K <br />I <br />BEDROO 4 <br />8'-0" FLAT CLq. <br />CARPET i <br />I `r <br />�I <br />K 2-CAR GARAGE <br />'3 8'-0" FLAT CLG. <br />EDGE OF SLAB 2" <br />BEYOND WALL�o <br />DRYER VENT�� <br />THRU ROOF <br />I <br />30681 1 <br />OI <br />B <br />= I ENTRY <br />V 1 8'-0" FLAT CLG. <br />4' <br />1 <br />40681B.F. <br />------------- <br />R&S <br />L5 G.T. <br />------ <br />I D <br />I I S3 <br />I <br />I <br />I <br />I d <br />S <br />cc tM O <br />c7 <br />uj '- <br />A <br />NCO <br />_ <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX254 <br />S.H. <br />13 <br />20 X 38 j <br />18 J X 37 1 <br />S.H. <br />14 <br />20 X 50 j <br />18 } X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 j <br />S.H. <br />16 <br />20X72 <br />184X714 <br />S.H. <br />J 32 <br />27 1/4 X 26 <br />26 X 25 <br />S.H. <br />j 33 <br />27 1/4 X 381j <br />N/A <br />S.H. <br />} 34 <br />27 j X 50 j <br />N/A <br />S.H. <br />433 <br />N/A <br />26 x 37 <br />S.H. <br />434 <br />N/A <br />26 x 50 <br />S.H. <br />J 35 <br />27 4 X 63 <br />26 X 62112 <br />S.H. <br />436 <br />27 j X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 4 X 26 <br />36 j X 251 /2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 4 X 37 314 <br />S.H. <br />24 <br />37 1 X 50 j <br />36 4 X 50 <br />S.H. <br />25 <br />37 j X 63 <br />36 j X 62 1/2 <br />S.H. <br />26 <br />37 J X 72 <br />36 j X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 <br />S.H. <br />33 <br />54 X 38 j <br />52 4 X 37 j <br />S.H. <br />34 <br />54 X 50 j <br />52 j X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 624 <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 } <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is Iocated.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />0 <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 ! -30.8 <br />OD <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />q MASONRY HGT. @ 9'-4" A.F.F. <br /><V <br />TYP. 2x FRAME WALL <br />= INTERIOR BEARING WALL <br />0 <br />v Y <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION <br />1ST FLOOR LIVING AREA 1817 <br />LIVING TOTAL 1817 <br />GARAGE 427 <br />FRONT ENTRY 32 <br />TOTAL AREA 2276 <br />C. <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />`V <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />M <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />w <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />UU110 <br />z o <br />CD <br />93 <br />;if <br />Z <br />a <br />z <br />V) C9 <br />Q� <br />cn <br />�--� W <br />O W <br />= <br />E <br />�Vi <br />_oo <br />U <br />W <br />�� <br />C tp M <br />go <br />U o <br />_ <br />U <br />� <br />� '� IT <br />o <br />law.. <br />" <br />=Jl I <br />Zz o I�J <br />U) <br />Z <br />d <br />SE <br />W f <br />o <br />, <br />To the best of the ngin ery ISnowledge, infRrldp' ron, <br />bellef, the structurat.}ylins aniespet'tfkeQbttt tdntai(�ti <br />within these drawings'y with fh,6 2017 Fly <br />Building Code - Residential 6tH E,�I;ion.l €n91�'S <br />signature and seal is only for the strihtural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />O <br />z NO <br />0 � N <br />�LO <br />>-,�Mp <br />M <br />Q V) M Lf) <br />cn•�� <br />G.0 <br />ON <br />Q LL <br />M <br />QV CL 00 <br />z§ <br />W <br />J � <br />d- <br />Z <br />w� <br />za <br />f a <br />F <br />O 0 1% <br />22 z z <br />z <br />0p�!�w <br />J <br />U11 <br />� F N <br />Zw® <br />L <br />^ <br />LL <br />Q) <br />CC <br />> <br />f z <br />Ily- <br />I� <br />O <br />L <br />�3 <br />0 <br />� <br />U <br />= <br />T <br />w <br />w <br />O <br />P <br />J <br />N <br />�0 <br />Z �¢ <br />0LLJ 3 <br />W.- <br />Z <br />J <br />Ln <br />r-4 <br />W <br />d,�0 <br />V"I <br />CC <br />G <br />z�d <br />U <br />(3) <br />Z <br />z <br />uj �� <br />m <br />O <br />o <br />g <br />i <br />rn <br />.-4 <br />a <br />cn <br />f <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAMES <br />VERSION N0. 4mO <br />SHEET NO. <br />1.0 <br />