ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />NEMA1 <br />200 AMP <br />n <br />200 amp <br />150 amp <br />copper to lights d outlets <br />copper to 20 amp ckts <br />•2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />Within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FF <br />WEATHERPROOF DUPLEX OUTLET <br />y W.P. <br />G.F.I. GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />g SPECIAL PURPOSE OUTLET <br />� DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />N <br />N WALL SWITCH <br />00 <br />7 $3 THREE-WAY SWITCH <br />a �'4 FOUR-WAY SWITCH <br />R RHEOSTAT SWITCH <br />it CEILING MOUNTED LIGHT FIXTURE <br />LED LED CEILING MOUNTED LIGHT FIXTURE <br />00 <br />g WALL MOUNTED LIGHT FIXTURE <br />J ORECESSED LIGHT FIXTURE <br />M <br />`I LIGHT FIXTURE WITH PULL CHAIN <br />0o P.C. <br />TRACK LIGHT <br />tr <br />FLOURESCENT LIGHT FIXTURE <br />=moo+ O EXHAUST FAN <br />;0/ EXHAUST FAN/LIGHT COMBINATION <br />Q ELECTRIC DOOR OPERATOR (OPTIONAL) <br />w <br />N CH CHIMES (OPTIONAL) <br />i <br />a <br />E PUSHBUTTON SWITCH (OPTIONAL) <br />oSD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />a� <br />L` ® TELEVISION (OPTIONAL) <br />0 <br />o ® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />cc <br />i owl ELECTRIC PANEL <br />CL <br />—�I DISCONNECT SWITCH <br />oD ® SPEAKER (OPTIONAL) <br />N <br />�/> <br />.; ROUGH -IN FOR OPT. CEILING FAN <br />U J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />J OPT. CEILING FAN <br />99 (1) PHONE LINE, (1) DATA PORT <br />H. <br />VERIFY METER LOCATION <br />WITH BUILDER <br />lli7 ROUGH -IN FOR <br />'• •' <br />• • MM • - <br />LIGHT PRE-WIR&\ 12 0 <br />_LIGHT PRE -WIRE <br />— <br />12 <br />_ LIGHT PRE-W / IRE A <br />ptl]l*•M <br />� r — <br />If <br />DEDICATED RECEPTACLE <br />� <br />�. lir II II IU 111 <br />II II <br />•• FOR FOR MICROWAVE <br />•' • ••D PER SPECS_ • <br />LIGHT PRE -WIRE <br />------------- <br />OW - • �� I • ' -iII <br />C • LLI <br />Mass1I ' . I I, i• , I � � • <br />LL <br />LU <br />1P 2-CAR GARAGE <br />� 111 � � — 'a, � •ill; F� i � ���� �- • <br />_ ^ 111 I <br />■ <br />�111 aGARAGE <br />- w uwsannnauu SPECSLIGHT AS IGARAGE <br />PER — <br />DOOR <br />GFI <br />EPA) <br />WP <br />_ I <br />GFI <br />ow <br />T <br />PRE -WIRE I <br />m�v <br />• • _ A.F.F. <br />FAMILY ROOM •,� . �`ir"�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII <br />111 <br />---------- 111------------------ ------------------ <br />H.B. <br />MAIN ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />F <br />0 <br />0 <br />; <br />Z <br />z <br />a <br />z <br />CZ <br />Ln 0 <br />C-f'> <br />Q <br />O <br />D-V) <br />EE <br />U <br />N � ri <br />w <br />t3 <br />W ® ~ Ep <br />ch <br />12 to t7 <br />- N <br />O O C <br />Al I <br />I �v <br />J <br />aas• � ,.rd � W C � L.L J <br />co LL N i0 l.l.l I.L <br />W— =L-9 a� <br />z g N w 7� <br />4N o <br />LLN m m <br />Z�W°'mx <br />2T <br />p <br />W N Q <br />O <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />i< <br />0 <br />Z N <br />O <br />P-4 4-J C <br />M O <br />M <br />aU-) MLr' <br />a •0 <br />N N <br />a)LL <br />G. ^ <br />oC � <br />Q 0000 <br />Z (0 <br />WJ <br />11.0 <br />W <br />;r <br />�z80, <br />acl: <br />tzw <br />WE <br />H <br />Z <br />M2 <br />S��® <br />Q <br />g <br />� <br />LL <br />Q <br />U <br />= <br />U <br />W <br />�W <br />o <br />J <br />W <br />qg�� <br />J <br />XO S� U <br />J <br />W ar <br />Q <br />s <br />Z <br />LLUU <br />Lr) <br />di <br />�u E <br />a <br />WLn 2: <br />L <br />Z <br />U <br />a <br />Im <br />Z <br />I <br />m <br />O <br />00 <br />5 <br />rn <br />,- 4 <br />a <br />to <br />f <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION NO' 4nO <br />SHEET NO. <br />4.0 <br />