DOOR JAMB (REFER 1X4 1/2" DRYWALL <br />DOOR JAMB (REFER 1 X 4 1/2" DRYWALL DOOR JAMB (REFER <br />1 X 4 1/2" DRYWALL <br />MAX. 8„ , UNACCEPTABLE INSTALLTION <br />, <br />TO SHT. SDW2-K1 P T <br />TO SHT. SDW2-K1 TO SHT, SDW2-K1 <br />FOR CONN. DETAILS <br />PROPER INSTALLATION <br />DO NOT DO THIS <br />♦ <br />' <br />2"x BOT. PLATE W/ (2)10d @ 6" O.C. <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS <br />1 X 4 <br />1 X 4 <br />♦ #5 REPAR <br />(TYP,) ' <br />3/4" PLYWOOD DECKING GLUED <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ <br />1 X 4 <br />3-1/4" LONG X 3/16"0 FURRING <br />3/16" 0 X 3" LONG FURRING �� " <br />TAPCONS 3/16 0 X 3-1/2 LONG <br />FURRING <br />#5 REBAR <br />♦ <br />AND NAILED W/ 8d COMMON @ <br />n <br />6" O.C. EDGES AND 12 O.C. FIELD <br />8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />TAPCON. INTO <br />TAPCONS STAGGEREDNX8 <br />STAGGERED @ 16 „ <br />X8 <br />(�,P) <br />♦ <br />'' <br />BLOCK@ SPACING �� <br />1 DETAIL <br />O.C. 2-ROWS INTO 1X8 P.T. STAGGERED @ 16 O.C. <br />2-ROWS INTO <br />41 � <br />BAND W/ FACE <br />PER MANUFACTURE <br />MASONRY THROUGH 1 _ 1 /2" DETAIL MASONRY THROUGH <br />3 <br />�� <br />DETAIL <br />SrrD. <br />STD. 90" ♦ Ij <br />90° HOOK (TYP.) <br />2x JOIST NAIL 10d <br />@ TOP & BTTM CHORD, AND (8) <br />1x4 P.T. & 1x8 P.T. 1x8 P.T. & 2x8 P.T. <br />FILL SOLID <br />BOTH CELLS <br />HOOK (TYP.) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />3/16" x 3 -1/2" <br />TAPCON @ 16" <br />METAL SEAT PLATE <br />O.C. & 4" FROM <br />1X4 P.T. 3/16" x 3 -1/2" DOOR JAMB (REFER <br />1/2" DRYWALL <br />NOTE: <br />DOOR JAMB (REFER EACH END W/ MIN, <br />DOOR JAMB REFER TAPCON TO SHT. SDW2-K1 FOR <br />( <br />1 X 4 <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />" <br />TO SHT. SDW2-K1 2 EDGE DIST. <br />TO SHT. SDW2-K1 CONN. DETAIL <br />7JOIST <br />TYPICAL <br />FOR CONN. DETAILS <br />FOR CONN. DETAILS 10d @ 12" O.C. <br />1 X 4 <br />_ _J <br />FURRING <br />2X8 P.T. WITH 3/16"0 X 3° <br />+2n <br />- <br />NOTC @ FIRST COURSE <br />IMP ON H M KTA 12" O.C. <br />@ <br />w/ (4)1/4x1 1/2"SDS SCREWS <br />LONG TAPCONS <br />2X8 P.T. <br />2X8 <br />2x P.T. AS REQ'D <br />STAGGERED @ 16" O.C. <br />I <br />♦ <br />- <br />INTO BAND JOIST & (4) 1/4 3/4" <br />2x DETAIL <br />2 1/4" DETAIL 2-ROWS INTO MASONRY 3-1 <br />/4" DETAIL <br />t5" <br />NOTCH WEB AT THE ' <br />FIRST 2 COURSES <br />♦ <br />TITEN INTO K.O. BLOCK <br />BUILDOUT OVER SIZE DOOR <br />-WINDOW ROUGH OPENINGS �cc <br />LED CELL PER <br />FOUNDATION PLAN <br />FILLED CELL INSTALLATION <br />KH <br />RETROFIT FOR MISSING <br />EMBEDDED STRAP <br />SCALE: N.T.S. <br />SS <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />SCALE: N.T.S. <br />SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />SECTION <br />UPLIFT CAPACITY = 805 #FOR 1 STRAP <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />A -A <br />=1610 # FOR 2 STRAPS <br />FILL 1st 4 COURSES <br />EMBEDMENT INTO BLK.) 1/4" MAX <br />n <br />SOLID W/GROUT <br />a 2'-0" <br />p <br />O <br />1 PLY PRE-ENGINEERED TRUSS <br />1 X 4 FURRING SOLID BLKG. AT TOP BTWN. <br />1/4" x 3 1/4"TAPCONS <br />BLOCK HEADER ARCH BLKG. & BUCK <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />1/2" DRYWALL * <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />8d NAILS AT 8" O.C. AT BUCK <br />SINKERS AND (7) 1/4"x2 1/4" TITEN = 2150 #) <br />2 x 8 45" DIAGONAL (4)10d NAILS INTO <br />LEAVE A CUT OUT IN O.S.B. ON THE <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />INSIDE TO ALLOW FOR INSULATION <br />7/16" OSB <br />TO BE INSTALLED <br />BOND BEAM OR CAST IN PLACE BEAM <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />POLY -CELL IN THIS AREA <br />2 x 8 45 DIAGONAL BRACE AT EA. <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. <br />SCRIBE (NOTCH) <br />BACKSIDE TO FIT ARCH (4)10d NAILS INTO 2 x 8 <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />RETROFIT TRUSS DETAIL <br />,'. <br />OVERRAN •�' <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />.. <br />N.T.S. <br />•. . <br />INSTALL WDW. SCREW ANCHOJ 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 PROVIDE TAPCON WITHIN <br />` ' <br />RETROFIT WALL OVERHANG DETAIL (NTS) <br />INTO ARCH BLKG. PER <br />A <br />4" MIN. OF BRACE <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />INSTALLATION DETAILS -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU <br />TRUSS AS SHOWN FOR O.H. UP TO 2'-6" <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />1-1/2" THK. OR MORE BUCK WITHIN 6" MIN. OF START OF <br />ARCH <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />* DOUBLE 2x4 SCAB FOR Z-6" TO 4'-0" O.H. <br />START OF ARC <br />IF TRUSSES USED) W/ (3) #6 X 4%" WOOD <br />NOTE: FOR OVERHANGS LESS THAN 3l4" - NO REPAIR REO'D. <br />4' MAX. RAD. <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />NAILS @ 8" O.C. <br />x 0� <br />FRHgN <br />ARCH DETAIL <br />WALL USE (3)1/4" X 31/2" TAPCONS AT 16" <br />TO TRUSS TOP CHORD <br />TO TR10dUSS <br />SCALE: N.T.S. <br />SS <br />O.C. 12 <br />* �Fiy <br />+ C'TN PLYWOOD SHEATHING <br />11 <br />11- 011 51- 0 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />+ + <br />+ + <br />OJUINISH FLO <br />2 x 8 BUCK - CONNECT TO BLOCK <br />SECTION <br />+ + r—BLOCKINGAS. <br />' � <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />B_B <br />ROOF SHEATHING ATTACHED <br />+ REQUIRED <br />> ► ► 424 <br />„ EMBEDMENT INTO ) <br />/4 MAX <br />PER NAILING SCHEDULE ALL <br />TO SUPPORT <br />TRUSS * <br />° .: • ►: #5 BAR <br />BLOCK HEADER SOLID BLKG. AT TOP BTWN. ARCH <br />2,-0„ 8" <br />(5)12d NAILS SIMPSON <br />SOFFIT <br />+ + <br />+ <br />ti . p: p <br />p : 1-0" • • . ° CENTERED W/ <br />R ► <br />BLKG. & BUCK <br />2X6 TO 2X4 H2.5A w/ (10) <br />2X4 SYP . ► <br />► ° IN TOP <br />N <br />1 X 4 FURRING <br />8d NAILS <br />EACH TRUSS <br />► d . ' KNOCKOUT / <br />_ <br />— CHAIR BLOCK <br />8d NAILS @ 8" O.C. AT BUCK <br />2 x 8 VERT. W/ (2)10d <br />PROVIDE 2 8 DIAG. BRACE B NAILS AT EA. END <br />PROVIDE (2) MIN. <br />PROVIDE 2x <br />CONT. WI <br />•� • <br />CONNECTOR � <br />_ <br />- — p' • • <br />MONO FOOTING _ ., �.: . , • <br />x <br />(3) <br />SIZE AND REINF. PER PLAN <br />VERT. BRACES WHEN HGT. OF <br />TAPCON AT EA. SIDE <br />12d NAILS <br />SEE LINTEL <br />_ <br />AND SECTION DETAILS <br />BRACE EXCEEDS 24" <br />BUCK - (1) WITHIN 4" <br />JACK TRUSS PROVIDED BYJ <br />SCHED. <br />LEAVE A CUT OUT IN O.S.B. ON T <br />MIN. OF START OF <br />TRUSS COMPANY OR 2x4 <br />CLEAN FILL • • <br />2 x 8 VERT. BRACES INSIDE TO ALLOW FOR INSULATION <br />() <br />ARCH <br />#2 SYP @ 24" O.C. <br />ENTER SO IT <br />.► <br />DIRT b z <br />TO BE INSTALLED <br />00, <br />BUILT UP PLWD. BUCK - <br />LAN <br />4'-0" MAXPRECAST <br />LINTEL <br />" STANDARD o <br />° 90' <br />HOOK 042X4 <br />SCRIBE (NOTCH) BACKSIDE 7/16" OSB ARCH PANEL <br />SYP #2 CONT. (MATCH TRUSS DEPTH <br />SEE ELEVATION <br />p <br />#5 BAR IN <br />TO FIT ARCH CONNECT W/ <br />START OF ARC <br />IF TRUSSES USED) W/ (2) #6 X 4%:" WOOD <br />FOR OVER HANG <br />FILLED CELL, • •. • �� -�� , , - , <br />8d NAILS 2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />4' MAX. RAD. <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />(MAX. 4'-0") <br />It 11016 . ._ N ., . _, �., <br />BTWN. OSB ARCH FACES W/ (4)10d NAILS EQUAL EQUAL <br />WALL USE (2)1/4" X 31/2" TAPCONS AT 16" <br />•; cis, <br />INSTALL WDW, SCREW <br />THRU OSB INTO 2 x 8 <br />O.C. <br />•• . •• . .• . .• • .- . <br />ANCHOR INTO ARCH BLKG. <br />rK <br />STEMWALL FOOTING SIZE AND <br />PER INSTALLATION DETAILS ARCH DETAIL <br />SECTION @ ENTRY L <br />SECTION @ ROOF EXTENSION M <br />REINF. PERLAN AND STEMWALL <br />�� <br />MONO TO STEMWALL FOOTING <br />SCALE: N.T.S. SS <br />SCALE: 3/4" = V-0" SS <br />SCALE: 3/4" = V-0" SS <br />SECTION DETAILS <br />SCALE: 3/4" = V-0" <br />GLASS BLOCK INSTALLATION NOTES <br />NOTE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJECT, <br />A) COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />CONTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />EXISTING BOND BEAM. <br />C) SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />MASONRY WALL. SEE PLAN FOR <br />D)SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />REINFORCING, PROVIDE LOWER <br />HOOKED DOWEL <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />SEE SHEET D2 AND <br />EPDXY CAP TO PREVENT LEAKAGE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />FLOOR PLAN FOR <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />MORE INFO <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />ANCHOR <br />SIMPSON HTT4 w/ (18)10d x 1 <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY t 2" ) <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />"SQUEEZED" <br />W.W.M. AT PERIMETER <br />1/2" NAILS TO STUDS & (1) - <br />COURSES TO PREVENT THE MORTAR FROM BEING OUT. <br />1/4" EXPANSION BOLT (2 <br />WHERE THIS CONDITION <br />(1) #5 BARS CONT. <br />5/8" DIA. ALL THREAD ROD <br />� #5x6' EMBEDDED INTO EXISTING BOND BEAM <br />E) INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />PER ANCHOR <br />9 ga. PANEL ) <br />OCCURS <br />TOP WITH MIN. 3" <br />EPDXIED wifN. SIMPSOD "SET' <br />o <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />COVER g�_0�� <br />EPDXY MIN. 6" EMBEDMENT & <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />F F <br />3" MIN. EDGE DISTANCE <br />FILL CELL FULL HEIGHT W/ <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) EXPANSION STRIP <br />LL w NON SHRINK GROUT. <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />o v <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />, ; p <br />v a A <br />REINFORCING AS FOLLOWS: <br />a 1 <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />`^ SEALANT <br />* PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />► ► <br />#5x6' EMBEDDED INTO <br />EXISTING FOOTING (2) #5x6' IN CONC. <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />vai FILLED CELL <br />SMOOTH. DO NO FURROW. <br />N DRILL 3/4"x5"MIN. HOLE <br />F) PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />GRADE ►. . ► <br />` . <br />SET BAR IN EPDXY <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />p <br />G) SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />th <br />H) STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION <br />NOTES. <br />r g p <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />° ° <br />a <br />4" SAW CUT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />\ ► (2) #5 REBAR. MIN. 3" <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />16" MIN. COVER EA. WAY <br />SECTION <br />00, <br />A <br />1) AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />EXISTING FOOTING <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />1 SCALE: N.T.S. <br />J) APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />SECTION AT DEEP MONO FOUNDATION <br />RETROFIT FOR MISSING MSTAM STRAP <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />RETROFIT FILLED CELL DETAIL <br />K) A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />"- „ <br />SCALE: 3/4 -1-0 <br />„- , „ <br />SCALE: 3/4 -1-0 <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />SCALE: N.T.S. <br />INSTALLATION OF GLASS BLOCK. <br />,1 <br />W <br />C9 . <br />z M <br />411111011111111111111 <br />z�z <br />a <br />z <br />W <br />c�/•)� (9 <br />4-- J w <br />� p <br />•O w <br />Cn c <br />U <br />LN' <br />= y <br />who_ <br />Cl) <br />pN <br />L LL OD <br />C ax6 <br />U �R OHO <br />¢ 0) <br />Sao <br />"t'. B. D. C. <br />� <br />P '• S E <br />`j �� <br />d <br />zo <br />� <br />Lq�t <br />V Q•'�� <br />". L O <br />1a• ° .... <br />W <br />tom- V' <br />• m <br />*� � <br />��!!Ililllt <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />CD <br />z N <br />0 cu N <br />0-4 <br />> M O <br />M <br />Qi-(aLh <br />G. in •� d- <br />Q U. <br />G. im <br />+ <br />�0ro a00 <br />Q � <br />� <br />W <br />z <br />J � <br />v <br />Ei <br />F- <br />$Z <br />z <br />LU <br />$al � <br />rl <br />V <br />L <br />z <br />U) <br />w <br />w <br />1�q6g11 <br />�QW3 <br />GC <br />J <br />LLJ <br />riLij <br />Q <br />Z <br />.�-•I <br />°° <br />N <br />06 <br />Z <br />g <br />tj <br />= <br />rn <br />r-q0- <br />cn <br />f <br />SCALE : AS NOTED <br />DATE : 3/15/2018 <br />TECH: MJAMES <br />VERSION NO. 4nO <br />SHEET NO. <br />SS <br />