Laserfiche WebLink
a <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />10 tl 14 copper to lights 8 outlets <br />NEMA 1 <br />20e AMP 10 #12 copper to 20 amp cM8 <br />10 R10.2 copper to WH <br />a 10.3 cropper to Dryer <br />METER <br />M_&IN T <br />0 2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />I POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />l NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />---------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and VERIFY METER <br />labeled by a Nationally Recognized Testing Laboratory. RECEPT. LOCATION WITH <br />10. Keep all smoke detectors minimum of 36" from bathroom doors FOR ALARM BUILDER H.B. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and SYSTEM <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />IRRIGATION <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an - - - - - - - - - - -1 VERIFY LOCATION - - - - A.T.F. <br />- - - - <br />GFI GFI @ 44 <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and I ELECTRICAL PANEL I I I <br />either hardwired or of the plug-in The exit alarm shall produce a continuous audible warning <br />P 9 type. P 9 ;--- ---- -- --} - - when the door or window are opened.. I I 1 1 O I I I <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing OWNERS S T I T E ' Al W.I.C. <br />machine. Receptacles oudests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the 1 I \ \ 2 CAR GARAGE I I I <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter l% / \ I I I I <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY -G J - I - - I -I I GFI FOR <br />/ ROUGH -IN FOR � I ( GAR. DOO�2 I I <br />OPT. CLG. FAN/ t- I GFI I I I <br />DUPLEX CONVENIENCE OUTLET LIGHT PRE -WI _ �- --- I- I GFI @ 44 I I I <br />DUPLEX OUTLET ABOVE COUNTER 1 A.F.F. I I I <br />PqT <br />S.D. f I P - _---WEATHERPROOF DUPLEX OUTLET O <br />PET-W.P. GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />I <br />bqp <br />I I <br />t <br />OPT. <br />J_ <br />HALF -SWITCHED DUPLEX OUTLETJI I I <br />i C.M OPT. <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR I I <br />220 VOLT OUTLET I 1 I _ — / L - - - - - - - - - - - - I I <br />$ WALL SWITCH I \ AHU _ _ _ __�__ I._- _ . GFI @ 44" <br />THREE-WAY SWITCH A.F.F. <br />$3 I FAMILY RM / - CH <br />14 FOUR-WAY SWITCH I <br />/ - .. <br />$R RHEOSTAT SWITCH ' I ENTRY <br />CEILING MOUNTED LIGHT FIXTURE <br />ROUGH -IN FOR / ' 1 ` (� j I <br />LED LED CEILING MOUNTED LIGHT FIXTURE I OPT. CLG. FAN/ / f WP <br />LIGHT PRE -WIRE - I - GFI <br />WALL MOUNTED LIGHT FIXTURE I _ _ _ _ _ _ <br />- - - - - - - - - - - - - - - 3 53 ____________ <br />ORECESSED LIGHT FIXTURE S.D. r S.D. <br />LIGHT FIXTURE WITH PULL CHAIN <br />P.C. <br />db <br />TRACK LIGHT " OPT. <br />GFI ' I REF.1 <br />Esr— <br />FLOURESCENT LIGHT FIXTURE �� I �- — — — — -_- —_ _ _ <br />GFI C------------ , GF - —r BEDROOM 2 �� S.D. 1 -. F <br />PA IO CAFE / F_(� - BEDROOM 4 <br />O EXHAUST FAN 1 't1'- - - : - B E D F�00 M 3 _ _ 1 <br />; F EXHAUST FAN/LIGHT COMBINATION / ` � D_W : - GFI 1 <br />IDIS 1 ROUGH -IN FOR <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) _ _ U. . S H - -- I OUGH-IN FOR �/ I f I OPT. CLG. FAN/ <br />HEN����•y I OPT. CLG. FAN/ I \ LIGHT PRE -WIRE <br />--- -- _ .. ' (ARL 4�S - LIGHT PRE -WIRE I <br />CH CHIMES (OPTIONAL) / PENDANT AS �-. �i� <br />PER SPECS \ -ice - + y . -- <br />ROUGH -IN FOR I I <br />PUSHBUTTON SWITCH (OPTIONAL) / <br />OPT. CLG. FAN/ I <br />- - - LIGHT PRE -WIRE <br />SD SMOKE DETECTOR ` : _ <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) AC PAD / / 3 ,µ-GPITi � ,{1,GF1 ,� ` IL <br />TELEPHONE (OPTIONAL) <br />01 <br />® TELEVISION (OPTIONAL) <br />H.B. <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. GFI DISC. <br />O THERMOSTAT <br />ELECTRIC METER <br />awn ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=V-0" I <br />C9 U')® <br />Z <br />z <br />Q <br />J <br />a. <br />U) z <br />Ln W C <br />w <br />0 w <br />I— <br />:.h r� <br />o <br />U <br />1y <br />co <br />M <br />E <br />82U <br />IJ r�a■ <br />o <br />Q1 <br />B D <br />" TCi <br />� <br />�� <br />N <br />�Z a <br />deal <br />N � m cc <br />LLO <br />W <br />a � � <br />To the best of the Engineer's knowledge, Information, and <br />bellef, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal Is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z NO <br />f\ <br />0IS <br />� V) CO C <br />_� M <br />Q�M_LA <br />,L <br />V) <br />Q C LL <br />a <br />F— <br />tY V <br />Q � <br />E <br />Z § ra <br />W <br />J <br />d' <br />fL <br />�a <br />Z <br />o ti <br />C <br />�z <br />LU <br />�} <br />UTeassi <br />VVV cm <br />�Q <br />Vessel <br />Q <br />IR <br />LU <br />M <br />J <br />w <br />_ <br />O <br />9"' <br />U <br />assesses. <br />Or <br />�� <br />z <br />"tl <br />Uo98 <br />U4o!:j <br />Q <br />Z <br />Z <br />^ <br />ju <br />Q <br />W <br />J <br />� <br />Ln <br />rl <br />W <br />W <br />2 <br />Z <br />b <br />_ <br />w <br />*k <br />N <br />Z <br />t <br />_ <br />rn 0 <br />00 <br />,-4 <br />� <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION NO. 4mO <br />SHEET NO. <br />4.0 <br />