Laserfiche WebLink
V (1) ROW 2x BLOCKING @ MID <br />2x #2 SPF STUDS HGT. FOR WALL HGT. <_ 8'-6". (2) <br />@16" O.C. W/ (2) ROWS 2x BLOCKING @ 3rd PTS <br />16d TOENAILS T & B FOR WALL HGT. > 8'-6". <br />1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z <br />APPLICABLE. <br />2x P.T. PLATE 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & _ci <br />@ 6" MAX FROM END OF 2 x PLATE <br />(1) LAYER TYPE II (#30) (2) #5 CONT. ON 3" 6 x 6 W1.4 x W1.4 <br />UNDERLAYMENT FOR ROOF CHAIRS (TYP.) WWF OR FIBERMESH cn <br />PITCH >4:12 0 ° <br />(2) LAYERS TYPE I OR TYPE II Y° <br />(#15 OR #30) UNDERLAYMENT — I 10,NO <br />FOR ROOF PITCH 4:12 OR LESFOR UNDERLAYMENT REQUIREMENTS SEE R905. PRE ENGINEERED WOOD °TRUSS @ 24" O.C. U.N.O.12 HURRICANE ANCHOR @ EACH <br />(TYP.) VARIES TRUSS (SEE UPLIFT SCHED.) W/ 8" <br />METAL PL. UNDER EA. TRUSS <br />MOISTURE BARRIER TYPICAL INTERIOR BEARING <br />INSULArlON LE SHINGLE ROOF <br />7/16" O.S.B. MIN. SEE ROOF WALL W/OUT UPLIFT GG <br />NAILING SCHEDULE ON SHT. SEE TYP. WALL SECTION <br />SN1 SCALE:3/4"=1'-0" S3 <br />ELEV. VARIES FOR ADDITIONAL SLAB <br />— INFORMATION. <br />5/8" OR 1/2" HIGH ALUMINUM DRIP <br />STRENGTH CEILING EDGE <br />BOARD PER CODE OR 5/8" <br />5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 BLOCKING 5/8"OR 1/2" HIGH STRENGTH — <br />(U.N.O.) (OR %" GYP. TYPE "X" @ W/ 2-16d TOE NAILS @EACH END e „ „ <br />GARAGE W/A HABITABLE ROOM (U.N.O.) (OR / GYP. TYPE X„ @ <br />ABOVE) EE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM <br />CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) <br />S.P.F. DOUBLE TRUSS ALIGNED WITH STUD BELOW / <br />8"x8"x16"NOMINAL BLOCK WITH TOP PLATE S.P.F. DOUBLE <br />TOP PLATE <br />3/8" MORTAR BETWEEN COURSES USP SPT24 <br />CONNECTOR 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 <br />1/2" CDX PLYWOOD OR 7/16" O.S.B. CONNECTOR <br />SHEATHING REQ'D. FOR ALL 1) ROW 2x BLOCKING @ MID HGT. FOR WALL <br />EXTERIOR OR SHEAR WALLS AS HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS <br />INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > 8'-6". <br />SHEATHING W/ 8d COMMON NAILS @ INSULATION PER CHART ON FLOOR PLAN <br />4" O.C. @ BOUNDARIES, 6" O.C. @ <br />MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD <br />SLAB & BLOCK SP 013T22 CONNECTOR <br />TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ <br />2-16d TOE NAILS @ EACH END <br />-SEE UPLIFT SCHEDULE FOR UPLIFT <br />CONNECTIONS. PROVIDE (1) USP HTW20 <br />WHEN TRUSS ALIGNED WITH STUD BELOW <br />,2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. <br />U.N.O. <br />---(1) ROW 2x BLOCKING @ MID HGT. FOR <br />WALL.HGT. < 8'-6". (2) ROWS 2x BLOCKING <br />@ 3rd PTS FOR WALL HGT. > V-6". <br />INSULATION PER CHART ON FLOOR PLAN <br />5/8"x 10" "J" BOLT 24" O.C. W/ Or'SPT22 CONNECTOR <br />5/8"° x 10" "J" BOLT @ 24" O.C. W/ Z"°x3/16" PLATE WASHER (TYP.) <br />2"°x3/16" PLATE WASHER (TYP.) <br />(ALT: 1/2"xl2" TITEN HD @ 24" 2x P.T. BOTTOM PLATE (ALT: 1/2"x12" TITEN HD @ 24" 2x P.T. BOTTOM PLATE <br />ELEV. 0'-0"OIL O.C. OR 5/8"x10' WEDGE ANCHOR O.C. OR 5/8"x10' WEDGE ANCHOR <br />A.F.F. @24"O.C.) 2" x6W1.4xW1.4 @24"O.C.) 211 6x6W1.4xW1.4 <br />WWF OR FIBERMESH WWF OR FIBERMESH <br />31/2" MIN. 31/2" MIN. <br />a ° ° ° ° 4 ° ELEV. 4-3 1/2" z <br />° ° ° 2x4 CONT. ° ° ° ° A.F.F. O ° „ ° _ <br />° ° 4 °' ° ' I I 1/2 (min.)- 4 ° ' r 1/2"(min.)- 4" <br />° GARAGE DEPTH VARIES ° ° d ° 31/2"(min. - 4" <br />° d ° ° , - <br />(2) #5 CONT. 4„ V-411 8" <br />GARAGE SLAB AT STEP rB TYPICAL BEARING WALL @ STEP (u) SHEARWALL <br />SCALE: 3/4"=V-0" S3 "SHEAR WALL" SCALE: 3/4"=V-0" <br />os�G�RE <br />GYP. TYPE "X" @GARAGE ALUMINUM FASCIA 1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING PCs. <br />W/A HABITABLE ROOM 12" N.O. 2x SUB FASCIA NAILED W/ 8d COMMON NAILS @ 4" O/C <br />2x S.P.F. STUDS @ 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. <br />ABOVE) W/DRYWALL EE SOFFIT ���s <br />SHEAR WALL REQUIRES 2x BLOCKING @SEAMS. MAN o� <br />SCREWS @ 7" O.C. SHEET LOAD BEARING OR 2x STUD (1) ROW 2x BLOCKING @MID HGT. <br />CEILING & 8" O.C. WALLS (2) ROWS OF 2x BLOCKING @ <br />8"x8"X16" KNOCK -OUT EXTERIOR WALL 8" C.M.U. 2x STUDS @ 16" 0/C FOR WALL HGT. < 8'-6". (2) <br />INSULATION PER 1"x P.T. STUD THIRD POINTS SEE SECTION C/S3 FOR <br />ULATION PER CHART ON FLOOR PLAN ROWS 2x BLOCKING @ 3rd PTS <br />BLOCK W/ 1#5 CONT. 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 ADDITIONAL INFORMATION FOR WALL HGT. > 8'-6". <br />CHART ON FLOOR FILLED SOLID W/GROUT #5 VERT. IN FILLED CELL 1/2" GYP. WB (MIN.) @ GARAGE <br />PLAN SEE CC/S3 OR N LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />1x2 P.T. HORIZONTAL G/S3 FOR ANCHOR 5/8"° x 10" "J" BOLT @ 24" O/C W/ 2"°X 3/16" METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL USP SPT22 CONNECTOR SIDE IF APPLICABLE. <br />8" C.M.U. TYPICAL 5/8"x6" "J" BOLTS BOLT PLATE WASHER TYPICAL 5/8— EXPANSION BOLT @24 " O.C. <br />NAILER BOLT INFO. 24" O.C. VERT. OR 3RD LAYER 1/8"THICK. K.O. BLOCK <br />(IF NO UP LIFT ON �° 2x P.T. PLATE <br />STD. 90-HOOK (SEE DETAIL) 5/8" x 6" EPDXY BOLT OR SP SPT22 @ EA. STUD W/ 7"EMBEDMENT (MIN. SHEAR <br />TYPE "S" MORTAR WALL SEE GG/S3) MIN. 2500 PSI CONCRETE SLAB W/ 3500#, MIN. TENSION 2600# <br />(6) 1/4"x3 1/4" TAPCONS 2X P.T. PLATE 20" MIN. LAP 24" MIN. LAP SPACE ANCHOR ) E <br />6x6W1.4xW1.4WWFOR [ ] <br />*USP SPT22 TYP. SPACED EVENLY #5 REINFORCING BOLTS 6" MAX FROM 6 x 6 W1.4 x W1.4 = <br />FIBERMESH WEEP SCREED INSTALLED BAR END OF 2" x PLATE WWF OR FIBERMESH r d <br />r 2x P.T. PLATE w , <br />ARCHITECTURAL C� PER MANUF. <br />FINISH ASSUMED FINISHED E #3 OR #4 REINFORCING BAR LU <br />LU <br />1x2 PT WD FURRING @ 24" O.C. ' ' GRADE , i .e ' o ° • z_ #3 & #4 LAP SPLICE GRADE 40 MIN. Fy= 40ksi a im, <br />(1) #5 VERT. IN FILL MONO OR STEMWALL M FINISH GRADE °O 2 25" MIN. LAP [30" MIN. LAP] [GRADE 60 MIN. Fy= 60ksi] a1/2" GYPSUM WALLBOARCELLS(SEE FOOTING MONO SHOWN o ° _ w <br />U.N.O. o _ _ _ °O 6 MIL VAPOR BARRIER R ° ° —op #5 REINFORCING BAR R 1 7/8 `� <br />FOUNDATION PLAN FOR CLARITY ° °. — r <br />FOR LOCATIONS) p I=III=1 = I=III= =1 I 1 �„ z - <br />1x4 P.T. BASE NAILER ° I I _EI I I=I I M I =1 I I= 11= z ° g (2) #5 CONT.__ <br />4"x4" INSPECTION o° I=1 I I=I I I=I I I=I I I=1 I =I 11 2 #5 LAP SPLICE <br />PORT AT EACH NOTE: ° D • e ON 3" CHAIRS <br />31/4" BASEBOARD *FOR BEARING WALL g III=III=III—III—III=I II r COMP. SOIL. (COMPACTED TO 36" MIN. LAP [36" MIN. LAP] TYP) 8° r-4° 8° <br />FILLED CELL TYPICAL =III=III=III=III= <br />W/ UPLIFT ONLY _ _ _ _ _ _ _ _ _ _ _ _ _ 95% MODIFIED PROCTOR ASTM — 10" <br />MIN. 2500 PSI CONC. SLAB _ _ _ _ _ _ _ —_ 1-07M-0iffli — <br />AT GARAGE CONTRACTOR III=III=I 1=III=III=III=III=III=1 I I=1 1=III=III=III=III=1 I II 1 D1557) I I I I #6 REINFORCING BAR #5 STD. 90 HOOK <br />MIN PSI MAY VARY PER cn =III -III —I =III=1 I= I= I=III=III—III=III=1 11= 1=III—4" 1'-4" <br />MUNICIPALITY. TO CUT BLOCK OR POUR "- I-III-III_-III=III=1=I I1=III=III-I i-1=1 i'- #6 LAP SPLICE TYPICAL INTERIOR BEARING <br />CURB DUE TO SLOPE ' —"'—' � �—� � �—"'—"'-- <br />CONCRETE SLAB W/6X6 n- NOTE:EXTEND FRAME WALL TO C.M.U. WALL CONNECTION D TYPICAL EXTERIOR FRAME WALL FOOTING E REBAR DETAILS rF WALL W/ UPLIFT G <br />W1.4XW1.4 WWF OR - DECO FINISH 4" to 6" <br />_FIBERMESH BELOW GRADE SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 SCALE: N.T.S. S3 SCALE: 3/4"=V-0" S3 <br />SLAB INFORMATION. SLAB INFORMATION. <br />Ih; 10. IIF=1L <br />SCALE:3/4"=V-0" \ S3 <br />E� <br />6 x 6 W1.4 x W1.4 <br />° <br />OP <br />31/2" WWF OR FIBERMESH <br />6 MIL VAPOR <br />> <br />z <br />min.) 4" <br />BARRIER <br />,I C 1 <br />Aoit. A <br />v GRADE <br />COMP. SOIL. <br />° <br />— — — <br />(COMPACTED TO 95% <br />M M <br />(1) <br />#EI <br />MODIFIED PROCTOR <br />— <br />—`— <br />ENCLOSURE <br />ASTM D1557) <br />3" MIN. CLR. <br />(2) #5 REBAR CONT. <br />4' <br />ON 3" CHAIRS TYP. <br />4" 1'-4" <br />STD. 90 HOOK (SEE <br />MIN. <br />U.N.O. <br />DETAIL) <br />TYPICAL WALL SECTION <br />rA <br />TYPICAL THICKENED SLAB EDGE <br />rL <br />SCALE: 3/4" = V-0" <br />SCALE: 3/471'-0" S3 <br />OPT: DEPRESS SLAB 5Y" DEEP <br />AND 6" BEYOND DOOR TO <br />RECEIVE PAVERS / DRIVEWAY BLOCK WALL BEYOND <br />CONCRETE SLAB <br />PAVERS 14' O.H.D. RECESS � z <br />� • ' _ �' TTT <br />- 4" I <br />SEE A/83 OR J/S6 <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />V " (1 STOR) ) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1' 8" (2 STOR ) <br />GARAGE DOOR SLAB RECESS J.1 <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />BLOCK WALL BEYOND <br />EXPANSION JOINT <br />13" <br />O.H.D. RECESS <br />s , <br />N <br />M <br />M !.• A. ti .:• .. <br />4„ <br />SEE A/S3 OR J/S6 <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 ST RY) <br />V-8" (2 ST RY) <br />GARAGE DOOR SLAB RECESS J <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />P.T. 2x 1/2" GYP. BD. <br />„ HOLD GYP. BD. <br />1/2" FROM SLAB <br />0� • J CONT. BEAD SEALM <br />INTERIOR <br />CONCRETE NAILS W 1 1/2 <br />EMBEDMENT @ 12" O.C. <br />STAGGERED, FROM BOTTOM <br />PLATE TO CONCRETE <br />(MIN. SHEAR 180# MIN. <br />TENSION 120#) CONCRETE SLAB <br /><4 A <br />0 <br />E_ <br />M 6 MIL VAPOR -=1 I = i' <br />BARRIER <br />ARIE <br />SEE PLAN <br />1 1/2" RECESS FOR <br />6 x 6 W1.4 x W1.4 <br />FRAME -DOWN FALSE BEAM w/ (3) <br />SEE ROOF PLAN <br />S.G.D. (U.N.O.) <br />WWF OR FIBERMESH N <br />10d NAILS TO TRUSS TOP CHORD <br />FOR TRUSS <br />co <br />AT 24" O.C. MAX. <br />SEE PLAN FOR <br />CONNECTION INFO <br />° <br />TOP OF BEAM <br />&LAYOUT DESIGN <br />.. <br />SEE ROOF PLAN <br />� <br />° �: ° <br />° < ° <br />FOR STRUCTURAL <br />_ <br />41 <br />BEAM SIZE & <br />N TU <br />a <br />zz4 P.T. <br />CONNECTION INFO <br />c i _ <br />° <br />8 , <br />PLATE <br />.•, <br />7/16" <br />I <br />I <br />o.s.s. <br />I <br />2x4 #2 SYP P.T. FRAMING w/ <br />MIN 7/16" O.S.B. SHEATHING <br />SEE A/S3/J/S6 <br />— <br />81' <br />COLUMN LOCATION <br />Z <br />ATTACHED PER NAILING <br />FOR REINF. INFO. <br />OPTION #1 <br />W <br />° <br />SCHEDULE <br />j <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />> <br />_j <br />SLAB INFORMATION. <br />W <br />N <br />SLAB STEP & RECESS <br />S.G.D. <br />rM <br />SEE FLOOR PLAN FOR <br />SCALE: 3/4"=1'-0" S3 <br />STRUCTURAL COLUMN SIZE <br />2X STUDS @ 24" O.C. U.N.O. <br />& BASE CONNECTION INFO, <br />SECURE 2x4 P.T. BTM. PLATE <br />MASONRY WALL AND <br />GARAGE <br />w/ 1/4"x3" TAPCONS AT 8" <br />PAD FOOTING <br />1/2" GYPSUM WALLBOARD U.N.O. <br />O.C. <br />8" MASONRY WALL <br />W/ DRYWALL SCREWS @ 8"O.C. <br />EXTEND FILL CELLS <br />TRIM PER PLAN <br />TO FOUNDATION PAD zt <br />INSULATION PER CHART <br />CONT. FOOTING STEEL <br />N <br />MAT REINFORCING. c <br />ON FLOOR PLAN <br />CONT. BEAD SEALANT <br />SQUARE CMU BLOCK BASE, <br />° ° <br />M <br />SIZE VARIES PER PLAN <br />O0 <br />= I 1 = _ <br />a <br />= 6x6W1.4xW1 <br />Cn <br />w/ MIN. (2) #5 VERTICALS <br />Tiff, 1 <br />II. I II I Il t <br />�• ° <br />r <br />WWF OR FIBERMESH Cn <br />FILLED SOLID <br />w <br />- <br />1 =1 <br />Lu <br />= 1= <br />Q <br />BRICK PAVERS or SLAB PER <br />O w <br />p o = <br />-III= <br />• • <br /><• <br />z <br />-- <br />a= <br />0'-0"FIN. FLR. <br />COMMUNITY SPECS <br />" <br />11=1 <br />° <br />=1 11=1 I=1 1=1 <br />I I <br />—_-- " ¢ <br />=1 I MI I-= J <br />=1 <br />— <br />- III <br />I I— II <br />II—�I <br />I-11 <br />—III I <br />I, <br />I 1=I11=I1 I_FOOTING � <br />I I—IIIII <br />I=l1 I I=1 1 11- <br />II;I.III II� <br />'TI <br />II <br />—I II-1 II=' BEYOND <br />PAD REINFORCEMENT <br />iII <br />. CLEARANCE <br />�•.,. <br />--- SEE SCHEDULE <br />WALL SLAB STEP NON-BRG. TAPERED COLUMN FRAMING D1 PATIO COLUMN FTG. DETAIL N <br />SCALE: 3/4"=V-0" 1 R-F, SME: 3/4— V-0" SCALE: N.T.S. <br />U LO <br />Z M <br />0 <br />— o <br />Z <br />Z <br />Q <br />J <br />CL <br />Z <br />Cz <br />cn <br />4-1 w <br />p <br />w <br />O <br />C <br />o <br />o0 <br />�Vi <br />U <br />dM <br />wE <br />— B <br />cmCl) <br />f`6 p CM <br />O o0 <br />U <br />LyY <br />r�T <br />0Yj:�, <br />05 O <br />Q rn <br />$G <br />1, 0 <br />A' <br />B D® <br />N•C a•N C <br />g � <br />� OWN o <br />q y <br />r� 0 6 <br />I <br />� <br />Z ! <br />II• LL <br />W <br />t <br />Z � <br />r,j�t�l6ti` �� <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />1f <br />O <br />O <br />Z cV <br />0c� <br />�tnMO <br />M <br />aUl)'gypLn <br />IZ Vf • i <br />En <br />Q W — In <br />rL <br />M <br />< V � <br />Q <br />Z M <br />J � <br />W <br />d' <br />�Z <br />w� <br />za <br />15 <br />'/^ <br />U) <br />J <br />va0� <br />$a�U <br />Q <br />z <br />z <br />" x w <br />LJU <br />0 <br />0. � Ix <br />J <br />j <br />o <br />� E <br />M <br />_x <br />K7J <br />0 <br />'0 <br />C <br />0 <br />U <br />2 <br />a' <br />Q <br />C) <br />Z <br />o <br />J <br />ri <br />0 <br />N <br />ZLn <br />Jr-1 <br />W <br />CWC <br />G <br />u z <br />Z V <br />SSS Q <br />co <br />Z~ <br />m <br />Z <br />Z <br />o <br />^ <br />g <br />� <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />S3 <br />(MONO) <br />