Laserfiche WebLink
FOR UNDERLAYMENT <br />REQUIREMENTS SEE R905. <br />12 <br />T <br />P') VARIES <br />INSUL ION LE / <br />5/8" OR 1/2" HIGHS <br />STRENGTH CEILING <br />BOARD PER CODE (OR 5/8" <br />GYP. TYPE "X" @ GARAGE <br />W/A HABITABLE ROOM <br />ABOVE) W/DRYWALL <br />SCREWS @ 7" O.C. <br />CEILING & 8" O.C. WALLS I <br />INSULATION PER -� <br />CHART ON FLOOR / <br />PLAN <br />1x2 P.T. HORIZONTAL- J/ <br />NAILER <br />STD. 90-HOOK (SEE DETAIL <br />2x #2 SPF STUDS - <br />J @16" O.C. W/ (2) <br />16d TOENAILS T & B <br />2x P.T. PLATE <br />(1) ROW 2x BLOCKING @ MID <br />HGT. FOR WALL HGT. <_ 8'-6". (2) <br />ROWS 2x BLOCKING @ 3rd PTS <br />FOR WALL HGT. > 8'-6". <br />1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z <br />APPLICABLE. <br />1/4" DIA. X 3 1/4" TAPCONS @ 24" O/C & <br />@ 6" MAX FROM END OF 2 x PLATE <br />(1) LAYER TYPE 11(#30) (2) #5 CONT. ON 3 6 x 6 W1.4 x W1.4 N <br />UNDERLAYMENT FOR ROOF CHAIRS (TYP.) WWF OR FIBERMESH Cl) <br />PITCH >4:12 R ° <br />(2) LAYERS TYPE I OR TYPE II <br />(#15 OR #30) UNDERLAYMENT =I I �I I I I m °' D I �I I I� I I I I o <br />FOR ROOF PITCH 4:12 OR LESS. <br />F--=I I F�=I I F=—I I <br />PRE ENGINEERED WOOD <br />TRUSS @ 24 O.C. U.N.O. <br />HURRICANE ANCHOR @ EACHZZ; <br />;TRUSS (SEE UPLIFT SCHED.) W/ 8„ <br />METAL PL. UNDER EA. TRUSS <br />MOISTURE BARRIER TYPICAL INTERIOR BEARING <br />,__SHINGLE ROOF <br />7/16" O.S.B. MIN. SEE ROOF WALL W/OUT UPLIFT GG <br />NAILING SCHEDULE ON SHT. SEE TYP. WALL SECTION <br />SCALE: 3/4"=1'-0" <br />SN1 ELEV. VARIES FOR ADDITIONAL SLAB S3 <br />- i <br />INFORMATION. <br />ALUMINUM DRIP <br />EDGE <br />ALUMINUM FASCIA <br />\-'llc2xSUBFASCIA <br />8"x8"x16" NOMINAL BLOCK WITH <br />3/8" MORTAR BETWEEN COURSES <br />00 <br />GARAGE SLAB AT STEP <br />SCALE: 3/4"=V-0" <br />5/8"OR 1/2" HIGH STRENGTH `TRUSS BOTTOM CHORD OR 2x4 BLOCKING ----/ \:2_1 <br />RUSS BOTTOM CHORD OR 2x4 BLOCKING W/ <br />(U.N.O.) (OR %" GYP. TYPE "X" @ W/ 2-16d TOE NAILS @ EACH END (U.N.O 1(O HIGH STRENGTH6d TOE NAILS @ EACH END <br />GARAGE W/A HABITABLE ROOM GARA .) (OR / GYP. TYPE X @ABOVE) GARAGE W/A HABITABLE ROOMSEE UPLIFT SCHEDULE FOR UPLIFT EE UPLIFT SCHEDULE FOR UPLIFT <br />CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) CONNECTIONS. PROVIDE (1) USP HTW20 <br />S.P.F. DOUBLE TRUSS ALIGNED WITH STUD BELOW WHEN TRUSS ALIGNED WITH STUD BELOW <br />TOP PLATE S.P.F. DOUBLE <br />USP SPT24 TOP PLATE <br />CONNECTOR 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. <br />1/2" CDX PLYWOOD OR 7/16" O.S.B. CONNECTOR U.N.O. <br />SHEATHING REQ'D. FOR ALL 1) ROW 2x BLOCKING @MID HGT. FOR WALL 1) ROW 2x BLOCKING @ MID HGT. FOR <br />EXTERIOR OR SHEAR WALLS AS HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING <br />INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > T-6". @ 3rd PTS FOR WALL HGT. > 8'-6". <br />SHEATHING W/ 8d COMMON NAILS @ INSULATION PER CHART ON FLOOR PLAN INSULATION PER CHART ON FLOOR PLAN <br />4" O.C. @ BOUNDARIES, 6" O.C. @ <br />3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD <br />SLAB & BLOCK 5/8"° x 10" "J" BOLT @ 24" O.C. W/ SP SPT22 CONNECTOR 5/8"° x 10" "J" BOLT @ 24" O.C. W/ SP SPT22 CONNECTOR <br />2" x3/16" PLATE WASHER (TYP.) 2"°x3/16" PLATE WASHER (TYP.) <br />(ALT: 1/2"x12" TITEN HD @ 24" 2x P.T. BOTTOM PLATE (ALT: 1/2"xl2" TITEN HD @ 24" 2x P.T. BOTTOM PLATE <br />ELEV. U-0" O.C. OR 5/8"x10' WEDGE ANCHOR O.C. OR 5/8"x10' WEDGE ANCHOR <br />A.F.F. @ 24" O.C.) 2" x 6 W1.4 x W1.4 @ 24" O.C.) 211 6 x 6 W1.4 x W1.4 <br />WWF OR FIBERMESH WWF OR FIBERMESH <br />�31/2" MIN. <br />a ELEV. 4-3 1/2" a <br />A.F.F. o ° <br />u.. <br />00 _ <br />° a N 31/2"(min. -4" II ° • _� III LI- <br />—III— =1Ti. <br />1/2" OR7/16" OSB MIN. PLYWOOD SHEATHING - <br />NAILED W/ 8d COMMON NAILS @ 4" O/C <br />- N. <br />. 2x S.P.F. STUDS @ 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. <br />EE SOFFIT 2x STUD SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. <br />SHEET LOAD BEARING OR <br />—1 I = U.gIII—III=III=T <br />� I <br />(2) #5 CONT. <br />4" 114" 8" <br />U.N.O. MIN. <br />TYPICAL BEARING WALL (c'>> STEP (@ SHEARWALL <br />"SHEAR WALL" SCALE: 3/4"=V-0" <br />�31/2"MIN. <br />° I I �I I �131 /2"(min.)- 4" <br />00 3 1/2"(min.) - 4" LI=� ° • =1 I ILFj I I <br />(2) #5 CONT.II I ITI�II 18 �' <br />U.N.O. MIN. <br />TYPICAL BEARING WALL @a STEPrcC <br />SCALE:3/4"=1'-0" �S3� <br />EXTERIOR WALL <br />8" C.M.U. <br />(2) ROWS OF 2x BLOCKING @ <br />THIRD POINTS <br />2x STUDS @ 16" O/C <br />8"x8"X16" KNOCK -OUT <br />1"x P.T. STUD <br />ULATION PER CHART ON FLOOR PLAN <br />BLOCK W/ 1#5 CONT. <br />FILLED SOLID W/GROUT <br />- <br />#5 VERT. IN FILLED CELL <br />7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 <br />SEE CC/S3 OR <br />N <br />LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />G/S3 FOR ANCHOR <br />"J" <br />5/8"° x 10" "J" BOLT @ 24" O/C W/ 2" X 3/16" <br />METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. <br />CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL <br />8" C.M.U. TYPICAL <br />BOLT INFO. <br />5/8"x6" BOLTS BOLT <br />PLATE WASHER TYPICAL <br />3RD LAYER 1/8" THICK. <br />K.O. BLOCK <br />( IF NO UP LIFT ON <br />@ 24" O.C. VERT. OR <br />SP SPT22 @ EA. STUD <br />TYPE "S" MORTAR <br />WALL SEE GG/S3) <br />5/8" x 6" EPDXY BOLT OR <br />MIN. 2500 PSI CONCRETE SLAB W/ -\\N <br />*USP SPT22 TYP. <br />(6) 1/4"x31/4" TAPCONS <br />SPACED EVENLY <br />6 x 6 W1.4 x W1.4 WWF OR <br />2X P.T. PLATE <br />20" MIN. LAP 124" MIN. LAP] <br />#5 REINFORCING <br />"' <br />2x P.T. PLATE <br />FIBERMESH <br />WEEP SCREED INSTALLED <br />BAR —� <br />ARCHITECTURAL <br />FINISH <br />ASSUMED FINISHED <br />- D <br />PER MANUF. <br />#3 OR #4 REINFORCING BAR <br />GRADE 40 MIN F - 40k ' <br />1x2 PT WD FURRING @ 24" O.C. ' ' GRADE N o D ° D z #3 & #4 LAP SPLICE <br />- y- sl <br />FINISH GRADE °° 2 [GRADE 60 MIN. l 60kIn <br />(1) #5 VERT. IN FILL MONO OR STEMWALL z M 25" MIN. LAP [30" MIN. LAP] <br />1/2" GYPSUM WALLBOARD CELLS (SEE FOOTING MONO SHOWN ° o ° - <br />FOUNDATION PLAN FOR CLARITY °D _ __ o0 6 MIL VAPOR BARRIER III I I - R 1 <br />U.N.O. ° -_ D ° o0 <br />FOR LOCATIONS) o ° P =III= -III =III ITI ° I I I=LL I I=III=-, T #5 REINFORCING BAR 7/8' -� <br />1x4 P.T. BASE NAILER U ° III=III=III=III=III= 1= ? I I D I-�TIIII i I r #�i I AP API IhF <br />4"x4" INSPECTION D n ° =III=I=1 =III- I= I I I • III- ! - <br />3 1/4" BASEBOARD NOTE: _ <br />PORT AT EACH III-III=1 = -III � COMP. SOIL. (COMPACTED TO -I D <br />*FOR BEARING WALL III=III-III- <br />FILLED CELL TYPICAL W/ UPLIFT ONLY _ _ _ _ _ _ _ _ 95% MODIFIED PROCTOR ASTM ' �= I I=I I J1=1 11= I -I I IT <br />MIN. 2500 PSI CONC. SLAB -III-III =III -III III = = III -III =III =I D1557 I I „ I I, �,1111 i IIIII 111 11111� r� I I- <br />M AT GARAGE CONTRACTOR =i = =III=III= = =III=III===III-III=1 -III_ ) 4" 1'-4" <br />MIN PSI MAY VARY PER TO CUT BLOCK OR POUR =III_ -III= =1 l=III=III=III III -I <br />MUNICIPALITY. - - - - - <br />CURB DUE TO SLOPE-"'-"-"I—"'-"'- <br />CONCRETESLABW/6X6 n NOTE:EXTEND FRAME WALL TO C.M.U. WALL CONNECTION D� TYPICAL EXTERIOR FRAME WALL FOOTING <br />W1.4XW1.4 WWF OR <br />"FIBERMESH" DECO FINISH 4" to 6" SCALE: 3/4"=V-0" <br />BELOW GRADE SEE TYP. WALL SECTION FOR ADDITIONAL <br />SLAB INFORMATION. <br />c`I I ° D 00 <br />- Z <br />6x6W1.4xW1.4 <br />D 31/2" WWF OR FIBERMESH <br />6 MIL VAPOR I D �� I I I Z min.) 4" <br />BARRIER c 1 a ° GRADE <br />D• • — r _ a • <br />COMP. SOIL. ° <br />(COMPACTED TO 95% - I I _ <br />MODIFIED PROCTOR I - - <br />ASTM D1557) <br />3" MIN. CLR. <br />(2) #5 REBAR CONT. <br />ON 3" CHAIRS TYP. 4" 1'4" STD. 90 HOOK (SEE <br />U.N.O. DETAIL) <br />TYPICAL WALL SECTION rA <br />SCALE: 3/4" = 1'-0" S3 <br />OPT: DEPRESS SLAB 5 Y" DEEP <br />AND 6" BEYOND DOOR TO - <br />RECEIVE PAVERS / DRIVEWAY <br />CONCRETE SLAB <br />PAVERS <br />BLOCK WALL BEYOND <br />14 Il J�O.H.D. RECESS <br />M <br />SEE A/S3 0R J/S6-'- -ILII1111 1111= <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1'-8" (2 STORY) <br />GARAGE DOOR SLAB RECESS ri T� <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />C —1 I I —III —III III —I ' <br />-(1) #5 REBAR w/ OPT. <br />I- II -SCREEN ENCLOSURE <br />MIN, <br />TYPICAL THICKENED SLAB EDGE L <br />SCALE:3/4"=1'-0" S3 <br />BLOCK WALL BEYOND <br />EXPANSION JOINT <br />13 O.H.D. RECESS <br />M ' <br />4. <br />M �..' <br />- <br />-1 I=III 4" II °° <br />�1 I I - <br />SEE A/S3 OR J/S6— -1 lil I I I II �,I i1 „Ill ,I 11- <br />FOR REINF. INFO. 3" MIN, CLEARANCE <br />1'4" (1 STORY) <br />V-8" (2 STORY) <br />GARAGE DOOR SLAB RECESS <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" <br />SLAB INFORMATION. <br />P.T. 2x 1/2" GYP. BD. <br />„ HOLD GYP. BD. 2 <br />1/2" FROM SLAB <br />QCONT. BEAD SEALANT <br />a INTERIOR <br />CONCRETE NAILS W 1 1/2' <br />EMBEDMENT @ 12" O.C. X <br />STAGGERED, FROM BOTTOM <br />PLATE TO CONCRETE x <br />(MIN. SHEAR 180# MIN. <br />TENSION 120#) CONCRETE SLAB <br />o? C _ <br />E� <br />�' <br />M 6 MIL VAPOR <br />BARRIERS--- <br />III=11 <br />�-- <br />4" 4" <br />INTERIOR WALL SLAB STEP NON-BRG. <br />SCALE: 3/4"=V-0" <br />-2X STUDS @ 24" O.C. U.N.O. <br />GARAGE <br />�1/2" GYPSUM WALLBOARD U.N.O. <br />W/ DRYWALL SCREWS @ 8"O.C. <br />-INSULATION PER CHART <br />ON FLOOR PLAN <br />CONT. BEAD SEALANT <br />E <br />6x6W1.4xW1.4 <br />`WWF OR FIBERMESH ( , <br />T-� a <br />K <br />S3 <br />NOTE: <br />SEE SECTION C/S3 FOR <br />ADDITIONAL INFORMATION <br />USP SPT22 CONNECTOR <br />2x P.T. PLATE <br />SPACE ANCHOR <br />BOLTS 6" MAX FROM <br />w END OF 2" x PLATE <br />� D <br />W <br />a 1=� I I—III=1 I I I <br />gUj <br />to T I1�11 I 111— <br />(1) ROW 2x BLOCKING @ MID HGT. <br />FOR WALL HGT. <_ T-6". (2) <br />ROWS 2x BLOCKING @ 3rd PTS <br />FOR WALL HGT. > T-6". <br />1/2" GYP. WB (MIN.) @ GARAGE <br />SIDE IF APPLICABLE. <br />5/8- EXPANSION BOLT @24 " O.C. <br />W/ 7" EMBEDMENT (MIN. SHEAR <br />3500#, MIN. TENSION 2600#) c <br />6x6W1.4xW1.4 <br />WWF OR FIBERMESH <br />I I I 1Ell <br />1 <br />(2) #5 CONT.— <br />ON 3" CHAIRS <br />TYP 8" 1'-4" 8" <br />10° <br />06 REINFORCING BAR <br />#5 STD. 90 HOOK <br />#6 LAP SPLICE <br />TYPICAL INTERIOR BEARING <br />REBAR DETAILS <br />rF <br />WALL W/ UPLIFT <br />rG <br />SCALE: N.T.S. <br />S3 <br />SCALE: 3/4"=V-0" <br />S3 <br />VARIES <br />SEE PLAN <br />FRAME -DOWN FALSE BEAM w/ (3) <br />SEE ROOF PLAN <br />1 1/2" RECESS FOR <br />S.G.D. (U.N.O.) <br />6 x 6 W1.4 x W1.4 <br />WWF OR FIBERMESH `I <br />10d NAILS TO TRUSS TOP CHORDFOR <br />TRUSS <br />M <br />AT 24" O.C. MAX. <br />SEE PLAN FOR All <br />CONNECTION INFO <br />° <br />TOP OF BEAM <br />& LAYOUT DESIGN <br />e . <br />SEE ROOF PLAN <br />F <br />�° <br />OR STRUCTURAL r - <br />BEAM SIZE & =1 <br />20P.T. I. 1 CONNECTION INFO <br />PLATE F [I <br />7/16 <br />0.5.8. <br />I 2x4 #2 SYP P.T. FRAMING w/ I I' <br />SEE A/S3/J/S6 i- <br />MIN 7/16" O.S.B. SHEATHING 8" <br />COLUMN LOCATION z ATTACHED PER NAILING FOR REINF. INFO. <br />W SCHEDULE OPTION #1 <br />> SEE TYP. WALL SECTION FOR ADDITIONAL <br />> -j SLAB INFORMATION. <br />w <br />U SLAB STEP & RECESS l S.G.D. M <br />SEE FLOOR PLAN FOR SCALE: 3/4"=1'-0" S3 <br />STRUCTURAL COLUMN SIZE <br />& BASE CONNECTION INFO. <br />SECURE 2x4 P.T. BTM. PLATE <br />w/ 1/4"x3" TAPCONS AT 8" <br />O.C. <br />TRIM PER PLAN <br />SQUARE CMU BLOCK BASE, <br />`t SIZE VARIES PER PLAN <br />Cl) w/ MIN. (2) #5 VERTICALS <br />FILLED SOLID <br />BRICK PAVERS or SLAB PER <br />0'-0" FIN. FLR. COMMUNITY SPECS <br />MASONRY WALL AND <br />PAD FOOTING <br />8" MASONRY WALL EXTEND FILL CELLS <br />TO FOUNDATION PAD E <br />CONT. FOOTING STEEL MAT REINFORCING. r ' <br />M <br />co GRADE a ° <br />0III=ill ° a. 1=III=III-III=1' <br />Z W —III —� = — —� W <br />00 0 = IIIII • •� • �• =1—I 1 z a <br />llILL <br />=1 =1=1=1 III -1=1 w <br />=1 IIIII=III=1 I=III=III III ill -I 1= FOOTING <br />-i =1 <br />- !111-11I-' BEYOND <br />PAD REINFORCEMENT =1=i <br />(SEE SCHEDULE) 3" MIN. CLEARANCE <br />FOOTING WIDTH <br />SEE SCHEDULE <br />PATIO COLUMN FTG. DETAIL ("N <br />SCALE: N.T.S. S3 <br />U' r <br />Z M <br />o <br />_ <br />z° <br />OJ <br />z� <br />Q <br />z <br />W <br />C� <br />nV�' <br />C—n <br />(DIM <br />w <br />p <br />w <br />0 Iti <br />~ <br />0 <br />o0 <br />U <br />w <br />F- <br />CD rnM M <br />c m Cl) <br />to <br />" <br />' <br />-8 <br />_ <br />tU- co <br />�o <br />Q rn <br />coo o0 <br />env <br />rn Q o <br />A 1 <br />B D. <br />NCHnC <br />o� o <br />n <br />�� . <br />LU <br />U <br />c a <br /><9 <br />O <br />� <br />MLU <br />a M �• <br />NtF <br />F Ss i <br />j \ <br />0\ <br />1�� <br />E <br />4!wIlll <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z <br />0 1� <br />�>-IU-)Mp <br />M <br />Q M Ln <br />a V) i <br />Q � LL r <br />Q <br />I— . <br />< U a00 <br />a <br />�� <br />z§� <br />J <br />W � <br />to <br />z¢o <br />(�! <br />J <br />Qoa <br />UwOor <br />O <br />O o <br />WU <br />Zwwlr <br />M�z4z <br />W <br />�IL <br />2 N <br />J <br />"moLwn <br />Q <br />Z O <br />¢U <br />% <br />TI <br />C <br />g <br />13 <br />g <br />a� <br />r <br />z <br />r—I <br />_0 <br />o <br />Z <br />O <br />_ <br />z <br />J ¢ <br />'Ow <br />Quo <br />00 � <br />J <br />10x�� <br />ZD <br />0 <br />mc)< <br />N <br />A <br />1 ` <br />LL— <br />Z w 0 J <br />w s ¢ <br />Q <br />Z <br />Pgge <br />D 2 <br />I1J <br />J <br />� <br />rl <br />W- <br />Q <br />�C7�j <br />o Z o <br />Ujuju <br />a8 <br />~ <br />l� <br />M <br />Q <br />Z <br />Z <br />a�Z <br />C� <br />a <br />o <br />^ <br />g <br />= <br />M Z <br />a� <br />� <br />a <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION N0. 2 . O <br />SHEET NO. <br />S3 <br />(MONO) <br />