My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3156 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3156 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:24:54 AM
Creation date
2/27/2025 1:06:56 PM
Metadata
Fields
Template:
Building Plans
Street #
3156
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19113
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I I JL ' 11 II 1 11111 I 111 11' III 1 111 <br />I A I I I I I I I IL I I" III I i <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />i <br />I <br />I <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />01 #12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />01 #103 copperto Dryer <br />METER <br />n <br />2/0 or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />I <br />POWER CO. FEED <br />t <br />l <br />INTERSYSTEM <br />4 Bare Cu Ground <br />I <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 08, 250.94 CLAMP PER 250.50 AND <br />l <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: <br />unless otherwise noted, <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />PE�PG GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />,?, 4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN <br />P.C. <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;Ot EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH I CHIMES (OPTIONAL) <br />0 PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />V J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT, CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />GFI <br />FAMILY ROOM CAFE <br />PENDANT AS <br />\ PER SPECS <br />\ \ — — — — — — — — — — — <br />ROUGH -IN FbR \ \ T-0" <br />\ OPT. CLG. F�N/ LIGHT \ <br />\ PRE -WIRE \ <br />� I <br />PFI <br />I \ _ <br />I 1 � <br />I C.M <br />M. <br />— — — — — — — — — <br />_ I _ i i I i <br />I <br />I ENTRY <br />WP <br />GFI <br />NONE z•.t, r <br />k / \ <br />/OWNER'S I <br />SUITE <br />� G � <br />I ROUGH -IN FOR <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />H.B. <br />W.I.C. ): - <br />----- --- <br />S.D a w���, —— - �- <br />'pW p '1 :SINKwI:. <br />— -- : DISP ; <br />L__ J <br />G111 U.C. SWITCH'', -- <br />- J-- -FOR-DISPOSAL - - <br />RANG <br />i- - A I <br />GI <br />o DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE C.M <br />HOOD PER SPECS <br />i <br />ROUGH -IN FOR <br />OPT. CLG. WN/ <br />LIGHT PRE}WIRd <br />BEDROOM 2 <br />S. <br />W <br />VP <br />4P IRRIGATION <br />GFI @ 44" A.F.F. <br />mil <br />IF------------ <br />II <br />I <br />I <br />I <br />I <br />I I rr l <br />I <br />1l I <br />I <br />I <br />I <br />I <br />� ,rr _j <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />'GARAGE <br />\ <br />GARAGE <br />j DOOR <br />j <br />LIGHT AS <br />I GFI <br />\ <br />PER SPEC <br />G <br />\ IL <br />2 C <br />A,@F. <br />/AR-GARA� <br />I <br />J <br />I <br />I <br />I <br />oQ <br />Qa <br />I <br />I <br />0Q <br />I <br />I <br />IY <br />u- U <br />I <br />I <br />I <br />I <br />W_j <br />> w <br />I <br />L — — — — — — — — — — — — <br />I <br />GFI @ 44" <br />A A.F.F. <br />— \ l .M 1T ----------------- <br />):rHALL \ ` S.D <br />\ \ <br />s.D � \ <br />EDROOM 4 <br />I <br />' v <br />ROUGH � <br />G. FOR G 1 ROUGH -IN FOR <br />LLIIGHT PRE-WIVRB E D F 00 M \ OPT. CLG. FAN/ <br />\ LIGHT PRE -WIRE <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN FLOOR ELECTRICAL PLANT <br />SCALE: %4"=1'-0" <br />LOU <br />0 <br />r- <br />zo <br />z� <br />Q <br />J <br />d <br />z <br />CD <br />n)n ' <br />�WW <br />U — <br />W <br />_(DI0 C <br />~ <br />O0 <br />v, <br />/R ~ <br />OO <br />m r <br />\J U <br />LU <br />W M <br />C7MM <br />E <br />m co�- (V <br />1 S <br />- LL 0000 <br />c Y <br />Cn a o <br />Q cm <br />to o -T <br />obi Q o <br />A ' <br />B D. <br />N C B D C <br />If <br />I <br />r <br />r_ <br />vCV <br />N_ <br />N <br />to <br />H g80) LO <br />tc <br />o 06 <br />Z04 -2� c <br />Z rn <br />U_ Z <br />W of cl) t0 <br />a� � u <br />d L U <br />a <br />W vcn- <br />z <br />Z Q <br />mow <br />m <br />In 2 0^0 <br />11y <br />LL-j <br />00 CIOZ9E�.2 ¢� <br />W Q vaN <br />N <br />o <br />0 <br />L) <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z N <br />0 � t\ <br />> °o <br />M <br />Q U) `0 L!1 <br />Z <br />CL <br />� <br />N _� U) <br />U_fn <br />f" <br />V (0,_1 <br />a 06 <br />Q <br />� <br />Z � <br />J <br />W <br />� <br />d- <br />oz <br />Za <br />aQ <br />fF <br />Zw <br />J0a <br />YCL <br />0W, <br />^ <br />FzFUZ <br />TptZZ <br />Lu 0 <br />n <br />as <br />ocew8 <br />U <br />" IN <br />� <br />� <br />ZZ <br />ro <br />z <br />W <br />U <br />0 <br />LL_ <br />LU <br />> <br />QY <br />0 c <br />Q <br />woOU <br />N <br />Q <br />ZW J <br />g�Z� <br />Z <br />�aEoe <br />aaZ <br />J <br />r1 <br />Q <br />W <br />$Ly~ <br />M <br />Z <br />��Z <br />cc)Z <br />W <br />:o <br />O <br />V <br />£ <br />T-11 <br />a <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.