My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3160 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3160 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:28:28 AM
Creation date
2/27/2025 1:07:07 PM
Metadata
Fields
Template:
Building Plans
Street #
3160
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
19979
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
General Notes <br />ROOF CRITERIA: <br />• 24" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />I barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />I accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />II stucco lath) over an approved synthetic house wrap. <br />I I R703.4 Flashing. <br />I I Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />ulk cavity or penetration of water to the building structural framing <br />I a I components. Flashing shall be installed at the following locations. <br />O • Exterior window/door openings. <br />0) ��Q I • Intersection of chimneys or other masonry contructions with <br />frame walls. <br />N • <br />Under and at the ends of masonry, wood or metal copings <br />:. I • and sills. <br />Continuously above all projecting wood trim. <br />I 1 ( I Where exterior porches, decks or stairs attach to a wall or <br />• I 1 1 <br />I 1 I • Atwallassembly <br />ofwood-frameconstruction. <br />II I <br />sections <br />• At Built-in gutters. <br />• II <br />z I1 I I <br />W u I <br />_ _ J Attic Ventilation <br />LL O I Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />ZONE-1 0 (2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />ATTIC SPACE � RIDGE : �"' space. The ventilating area maybe reduced to 11s p provided that p lean portion <br />�T®� but no more than 5096 of the required ventilation is provided in the upper portion of <br />I:12� SLOPE ICJ the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />tP 5:12 SLOP ' (measured vertically) below the ridge or highest point of the space, with the <br />I 2002 <br />'� O O ^ ^ T Z 4'-0' RIDGE VENT balance of the required ventilation provided by save or cornice vents. <br />L L l�X/ ' W �1 LLA a I "'CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />I ILL> <br />O P�� OJ (Values to be verified I RIDGE VENTS with Manufacturer <br />SO. IN. OFNETFREE AREA / LINEAR FT. <br />co <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />� N <br />4 • SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />:::: ;! • ; ; :: 'S% :: RIDGE <br />:19:-0-RIDGE•VENT•::: <br />W <br />O <br />U) <br />J <br />:. .... RIDGE <br />Chili 0 <br />.......... <br />............ ........ .............. ........................ ......... .......... ...... .......... <br />I • : • • • • • • • • • • • • <br />ROOF PLAN <br />SCALE: Y4'=V-0" <br />ATTIC VENTILATION CALCULATIONS - B1 <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off-RidgeKill <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />- <br />---------- <br />-- ---- <br />— <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />required soffit <br />ventilation <br />soffit <br />provided <br />by upper <br />Ventilation <br />Ventilation <br />See Elev <br />( ) <br />needed <br />required <br />needed <br />ventilators <br />Main <br />22.00000 <br />2.000000 <br />Floor 2002 1922 275 961 69 480 <br />0 <br />606.0 <br />(Zone 1) - — ---- - - ----- - — <br />330.0 <br />276.0 <br />"NOTE"" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED <br />AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />Z M <br />z <br />z <br />Q <br />a <br />lJ') C9 <br />cn <br />w <br />w <br />� <br />U. <br />Q� <br />0 <br />�i4t o <br />B D <br />D. <br />N C <br />To the best o$t¢e Epgl"er's kridWle ge, in(tk+nat 'and <br />belief, the struc{ural {SIaslSand sp#clfl <br />
The URL can be used to link to this page
Your browser does not support the video tag.