My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3161 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3161 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:32:30 AM
Creation date
2/27/2025 1:07:18 PM
Metadata
Fields
Template:
Building Plans
Street #
3161
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
18879
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I I I 1 ll'- <br />L 'II'itl 1 I <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />RESISTIVE <br />BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WE <br />✓E BARRIER & <br />tARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />ED FLASHING <br />L <br />SELF -ADHERED FLASHING <br />DOUBLE <br />JOIST <br />I <br />SINGLE <br />WOOD BEAM <br />JOIST <br />BELOW <br />NOT USED <br />SELF -ADHERED SELF -ADHERED <br />FLASHING FLASHING <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />0 <br />Q <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />i� SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4%1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF-ADHER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />/0 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />SELF -ADHERED FLASHING FOUNDATION WEEP SCREED <br />OUTSIDE CORNER ' ' • <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />Q <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF <br />NEEDED IN CORNERS <br />THROUGH SELF -ADHERED <br />FLASHING <br />mo <br />RUBBERIZED RUBBERIZED ASPHALT <br />ASPHALT ADHESIVE ADHESIVE <br />- SELF -ADHERED FLASHINGI- <br />®RN <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />�Ground7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R612.10 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches 152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.1 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.8 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration ofwater to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as ## in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material I x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />WEEP SCREED DETAIL <br />NOT USED . NOT USED \ I / <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />U� <br />Z o <br />- o <br />z� <br />Q <br />J <br />Q <br />a--J w <br />(10 p <br />�U <br />- <br />O w <br />0 <br />E <br />rr^^ <br />�v' F- <br />(6 <br />OM <br />o <br />m ti <br />U <br />LU <br />WM <br />C@ co <br />E <br />k <br />W <br />m2 0 <br />co <br />= <br />U� <br />U_ co <br />7 <br />0CL0 <br />Y <br />Qrn <br />0 O : <br />rnQo <br />A1 <br />B D. <br />N`a°` <br />IV, <br />N <br />N <br />1� N <br />_ <br />v mCN <br />� y 00 <br />0 00 <br />JA 0 <br />Z IW �NrnZ �� <br />J <br />W Q M N <br />m mW <br />LU <br />01- UJ <br />a <br />W <br />10VQn.- <br />ZC�rnm= <br />Z <br />.n p 2 9' <br />o O <br />X m <br />DoN� <br />V m <br />��� <br />IL a <br />a� <br />W ,<Nw <br />N co <br />J <br />0 <br />C) 0 <br />U F- <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />0 <br />Z cV <br />O a) N <br />,-1 4-J O <br />4 <br />►>-i (n M O <br />QU-)'pLn <br />Z <br />a to <br />U-) <br />Q a Ln <br />U Q� <br />Q <br />, <br />E <br />Z <br />WJ <br />� <br />J <br />OZ <br />�o <br />3E <br />c: p <br />W <br />z<a <br />z� <br /><< <br />+u<g, <br />go <br />goy <br />p Z Z <br />� X: J <br />J <br />H 2 N <br />W <br />mo <br />'ZZ <br />0 Zo <br />i <br />< <br />w <br />� <br />z <br />Z <br />Z <br />V' <br />g� <br />N <br />O <br />rl <br />O <br />s <br />O <br />.p_ <br />Z <br />Z <br />< <br />U <br />= <br />�f <br />8� <br />a Ro <br />° o <br />F-- <br />Xos <br />Q <br />dirm.1 <br />N <br />oa <br />woaWZ¢ <br />Z <br />Q <br />^ <br />~fo <br />� <br />Z <br />oM0 <br />Z <br />f <br />J <br />'-1 <br />LU <br />Q <br />LLJ <br />Zoo <br />� , o <br />o w u <br />l0 <br />z <br /><z <br />aN <br />V <br />g <br />Z <br />J <br />aW <br />o <br />^ <br />= <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: ERAND <br />VERSION N' 10 <br />SHEET NO. <br />WP <br />
The URL can be used to link to this page
Your browser does not support the video tag.