ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA1 #12 co <br />200 AMP pper to 20 amp ckts <br />#10-2 copper to wH <br />#10-3 copper to Dryer <br />MAIN <br />O2/0 <br />or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />LGROLINDING <br />BONDING <br />o <br />WIRE <br />TERMINATION PER <br />71 <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f. <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />Iwo EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />WWI ELECTRIC PANEL <br />_-E§=L DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 <br />Z O <br />z <br />Q <br />J <br />z <br />n <br />n , <br />n <br />Q) N <br />w <br />�V _ <br />0 w <br />Lv <br />m <br />l <br />E <br />O <br />,^^ <br />In <br />_0 m <br />LU <br />C t6 M <br />—� <br />W f— O <br />t0 'd M <br />Ooo <br />_ <br />�`-� <br />Uco <br />(D <br />(D <br />a) a. o <br />0 <br />Q rn <br />`n <br />0) 0 <br />B D. <br />ti <br />cli <br />co <br />�i cc <br />CV <br />y o 0 0 c°O.r <br />N <br />z °° <br />O <br />Z W N r Z <br />z <br />r 3 1 L- o � <br />W I,r <br />W aU N <br />W V L a.�u:_o <br />a.- <br />a W <br />a <br />z <br />Z O t< <br />z <br />o <br />�ypoC <br />or- <br />r <br />Vi�Em °1 <br />�m <br />m <br />QV<N� <br />U0Z <br />Q g <br />W N Q c) <br />bU <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O <br />o <br />� <br />V) M O <br />Imo+ <br />Q <br />•i <br />d to <br />Q U_ <br />OL 1-11 <br />oC UM <br />Q 00 <br />a <br />E� <br />� <br />Z � <br />WC:) <br />J <br />� <br />d- <br />J <br />oZ <br />�o <br />3� <br />w� <br />zaa <br />z <br />a <br />z <br />Q <br />f � <br />Zc_ <br />< 0 i= <br />J <br />^ <br />�Z0O <br />Z <br />L.L <br />J <br />!_UZ <br />�owZ <br />ofX LH <br />aO�n <br />OV � LL N <br />W <br />U <br />8wo <br />OZ <br />z z <br />l� <br />F_ <br />Qo <br />�z <br />> <br />,-aq <br />U <br />Z r <br />Z <br />LLJ <br />o a <br />v 3 <br />J <br />LUTeaeal <br />8 <br />J Q <br />= <br />0 <br />LL <br />>WZ <br />� <br />QYo <br />p M <br />J O <br />O <br />Z <br />X <br />good <br />�trm� <br />oaoc <br />W<z� <br />Q <br />~fo <br />Z <br />Cy o <br />Z <br />+�i <br />J <br />T,t <br />w <br />Q <br />�"< <br />l� <br />,—I <br />Lli <br />Q <br />Z <br />Z <br />a W < z <br />Z <br />*k <br />a <br />Q <br />� <br />QJ <br />a:` <br />z <br />rn <br />+—I <br />a <br />to <br />E <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: ERAND <br />VERSION N0. 10 <br />SHEET NO. <br />4.0 <br />