Laserfiche WebLink
m <br />00 <br />!R1 <br />a <br />00 <br />t— <br />iu <br />E <br />x <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY; <br />BON <br />TERMINATIOIS <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opper to lights & outlets <br />upper to 20 amp clas <br />copper to WH <br />copper to Dryer <br />t au <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />PFWF <br />HALF -SWITCHED DUPLEX OUTLET <br />Liph SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />O <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />99 <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />DISC. <br />J <br />GFI — <br />'WGFIFI —4 — <br />r - - OPT. <br />I REF. <br />I <br />KITCHEN <br />IGF ---- ---_-- <br />J�I__I_.... <br />LJ GFI l <br />DINING ROOM <br />I <br />/PENDANT AS \ <br />/ PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />VERIFY LOCATION " IRRIGATION _ _ _ _ <br />ELECTRICAL PANEL F GFI @ 4 V' A.F.F <br />I <br />I <br />I <br />/ � I <br />\ I <br />I <br />I <br />� � I <br />� \ I <br />\ I <br />\ � I <br />GFI FOR I <br />GFI @ 44" GAR. DOOR <br />A.F.F. GFI <br />I <br />� I <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OL------------ <br />6 GFI @ 44" <br />W.H. 'e.F.F. <br />\ - - - - . <br />FOYER i <br />\ i <br />ROUGH -IN FOR / <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED <br />FAMILY ROOM / <br />/ <br />401 �� 1 --- <br />� I I I <br />\ 1 I I <br />H.B. <br />-- FLEX <br />TO 2ND <br />- FLR. 0 <br />--- ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />Eel <br />GFI <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />0 <br />z QX� <br />Z <br />z <br />Q <br />a <br />V) 0 <br />� w <br />Q <br />U — <br />0 LLJ <br />e <br />I- <br />(.h c <br />U <br />w <br />M <br />m <br />R <br />�- <br />U_ <br />U <br />c <br />� <br />Q <br />o <br />B D. <br />ao <br />� <br />Z F Z --Z <br />fALL <br />� z <br />LU ease U., <br />Og`°'� <br />�ZLL, <br />L;j <br />W <a <br />N <br />o <br />c <br />% <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />0 <br />Z <br />0 <br />� M C <br />Z <br />M <br />f6 In <br />1L <br />0 <br />Z <br />Q Ln <br />" LL <br />�- CL . r. <br />Q 00 <br />E u <br />Z ry <br />WJ <br />0 <br />A <br />z <br />W in <br />�a <br />H <br />a <br />�Cj U <br />3Uce <br />CL <br />I <br />z <br />U <br />lye® <br />L <br />_ <br />Ln <br />C <br />Z <br />Ln <br />ILIU <br />W <br />N <br />-a <br />N <br />0 <br />O <br />0 <br />W <br />W <br />QQ <br />J <br />Z <br />J <br />Ln <br />rl <br />1LiJ <br />X <br />LJJ <br />� <br />Z <br />z <br />a g <br />In <br />T� <br />m <br />N <br />Z <br />ZQ <br />O^ <br />00 <br />a <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO. 5al <br />SHEET NO. <br />4.0 <br />