Laserfiche WebLink
FOR UNDERLAYMENT <br />REQUIREMENTS SEE R905. <br />12 <br />(TYP') VARIES <br />INSULATION LE <br />5/8" OR 1/2" HIGHS <br />STRENGTH CEILING <br />BOARD PER CODE (OR 5/8" <br />GYP. TYPE ")C" @ GARAGE <br />W/A HABITABLE ROOM <br />ABOVE) W/DRYWALL <br />SCREWS @ 7" O.C. <br />CEILING & 8" O.C. WALLS / <br />INSULATION PER —J <br />CHART ON FLOOR / <br />PLAN J <br />1x2 P.T. HORIZONTAL <br />NAILER <br />STD. 90-HOOK (SEE DETAIL <br />5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 BLOCKING TRUSS BOTTOM CHORD OR 2x4 BLOCKING W/ <br />(U.N.O.) (OR %" GYP. TYPE "X" @ W/ 2-16d TOE NAILS @ EACH END (U.N.O 1(O HIGH STRENGTH " 2-16d TOE NAILS @ EACH END <br />GARAGE W/A HABITABLE ROOM (U.N.O.) (OR / GYP. TYPE X @ <br />ABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT GARAGE W/A HABITABLE ROOM EE UPLIFT SCHEDULE FOR UPLIFT <br />CONNECTIONS. PROVIDE (1) USP HTW20 WHEN ABOVE) CONNECTIONS. PROVIDE (1) USP HTW20 <br />S.P.F. DOUBLE TRUSS ALIGNED WITH STUD BELOW WHEN TRUSS ALIGNED WITH STUD BELOW <br />8"x8"x16" NOMINAL BLOCK WITH TOP PLATE TOP PLATE LE <br />3/8" MORTAR BETWEEN COURSES USP SPT24 <br />CONNECTOR 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. USP SPT24 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. <br />1/2" CDX PLYWOOD OR 7/16" O.S.B. CONNECTOR U.N.O. <br />SHEATHING REQ'D. FOR ALL 1) ROW 2x BLOCKING @ MID HGT. FOR WALL 1) ROW 2x BLOCKING @ MID HGT. FOR <br />EXTERIOR OR SHEAR WALLS AS HGT. < 8'-6". (2) ROWS 2x BLOCKING @ 3rd PTS WALL HGT. < 8'-6". (2) ROWS 2x BLOCKING <br />INDICATED ON THE PLAN. ATTACH FOR WALL HGT. > 8'-6". @ 3rd PTS FOR WALL HGT. > V-6". <br />SHEATHING W/ 8d COMMON NAILS @ INSULATION PER CHART ON FLOOR PLAN NSULATION PER CHART ON FLOOR PLAN <br />4" O.C. @ BOUNDARIES, 6" O.C. @ <br />3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @ FIELD <br />SLAB & BLOCK 5/8" x 10" "J" BOLT @ 24" O.C. W/ SP SPT22 CONNECTOR 5/8"° x 10" "J" BOLT @ 24" O.C. W/ SP SPT22 CONNECTOR <br />2"°x3/16" PLATE WASHER (TYP.) 2"°x3/16" PLATE WASHER (TYP.) <br />T (ALT: 1/2"xl2" TITEN HD @ 24" 2x P.T. BOTTOM PLATE (ALT: 1/2"x12" TITEN HD @ 24" 2x P.T. BOTTOM PLATE <br />"' ELEV. 0'-0" OIL O.C. OR 5/8"x10' WEDGE ANCHOR O.C. OR 5/8"x10' WEDGE ANCHOR <br />2„ x6W1.4xW1.4 @24"O.C.) 2" 6x6W1.4xW1.4 <br />° a A.F.F. @ 24" O.C.) WWF OR FIBERMESH WWF OR FIBERMESH <br />° ° � 31/2" MIN. 31/2"MIN. <br />° ELEV. -0'-31/2" z <br />A.F.F. '0° <br />° a 2x4 CONT. a ° <br />a ° A' `31/2"(min.)- 4" _ n ° ° - 31/2"(min.)- 4" <br />a v ° g' ° d ° a N 00 <br />° •. ° ••• <br />GARAGE DEPTH VARIES <br />° T <br />(2) #5 CONT. 41, ' 1 1,4- " (2) #5 CONT. 41' <br />U.N.O. MIN. U.N.O. MIN. <br />GARAGE SLAB AT STEP B TYPICAL BEARING WALL P STEP SHEARWALL C TYPICAL BEARING WALL @ STEP rCC <br />SCALE: 3/4"=1'-0" S3 "SHEAR WALL" SCALE: 3/4"=V-0" S3 SCALE: 3/4"=V-0" v <br />COS' s R1'1� <br />GV <br />ems' <br />M�N�M�o S <br />(2) ROWS OF 2x BLOCKING @ p�- ,� N�`N <br />EXTERIOR WALL 2x STUDS 16" 0/C <br />8"x8"X16" KNOCK -OUT 8 C.M.U. THIRD POINTS @ / NOTE: <br />BLOCK W/ 1#5 CONT. 1"x P.T. STUD ULATION PER CHART ON FLOOR PLAN SEE SECTION C/S3 FOR <br />FILLED SOLID W/GROUT #5 VERT. IN FILLED CELL 7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 ADDITIONAL INFORMATION <br />SEE CC/S3 OR LAN LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />G/S3 FOR ANCHOR METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. CONTINUOUS TO FOOTER BELOW 90 Fi00K DETAIL USP SPT22 CONNECTOR <br />BOLTS BOLT 5/8"° x 10" "J" BOLT @ 24" O/C W/ 2"°X 3/16" <br />�8" C.M.U. TYPICAL BOLT INFO. PLATE WASHER TYPICAL 3RD LAYER 1/8" THICK. K.O. BLOCK <br />(IF NO UP LIFT ON @ 24" O.C. VERT. OR 2x P.T. PLATE <br />5/8" x 6" EPDXY BOLT OR SP SPT22 @ EA. STUD <br />TYPE "S" MORTAR WALL SEE GG/S3) MIN. 2500 PSI CONCRETE SLAB W/ SPACE ANCHOR <br />(6)1/4"x31/4" TAPCONS 6 x 6 W1.4 x W1.4 WWF OR 2X P.T. PLATE 20" MIN. LAP [24" MIN. LAP] #5 REINFORCING BOLTS 6" MAX FROM <br />*USP SPT22 TYP. SPACED EVENLY J <br />FIBERMESH NWEEP SCREED INSTALLED BAR w END OF 2" x PLATE <br />2x P.T. PLATE <br />ARCHITECTURAL PER MANUF. o • <br />FINISH ASSUMED FINISHED E #3 OR #4 REINFORCING BAR <br />1x2 PT WD FURRING @ 24" O.C. ' t GRADE �, • ° D _ z_ #3 & #4 LAP SPLICE GRADE 40 MIN. Fy= 40ksi — <br />'- ° FINISH GRADE 60 [GRADE 60 MIN. Fy= 60ksi] p . <br />(1) #5 VERT. IN FILL MONO OR STEMWALL ° z M a <br />a ► • 25"MIN. LAP [30" MIN. LAP] <br />1/2" GYPSUM WALLBOARD � <br />CELLS (SEE FOOTING MONO SHOWN 1, I - - <br />U.N.O. D °D _ _ _ _ _ 00 6 MIL VAPOR BARRIER I - w - ° <br />FOUNDATION PLAN FOR CLARITY ° e. ° R 1 7/8" <br />FOR LOCATIONS) D ° D I-1 I =1 I -III -III- I = <br />#5 REINFORCING BAR <br />v (1) ROW 2x BLOCKING @ MID <br />2x #2 SPF STUDS HGT. FOR WALL HGT. < V-6". (2) <br />@16" O.C. W/ (2) ROWS 2x BLOCKING @ 3rd PTS <br />16d TOENAILS T & B FOR WALL HGT. > 8'-6". <br />1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z <br />APPLICABLE. <br />2x P.T. PLATE 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & <br />@ 6" MAX FROM END OF 2 x PLATE _E <br />(1) LAYER TYPE II (#30) (2) #5 CONT. ON 3" 6 x 6 W1.4 x W1.4 N <br />UNDERLAYMENT FOR ROOF CHAIRS (TYP.) WWF OR FIBERMESH <br />PITCH >4:12 v° <br />(2) LAYERS TYPE I OR TYPE II ° <br />(#15 OR #30) UNDERLAYMENT - %8" <br />FOR ROOF PITCH 4:12 OR LESS.A. <br />PRE ENGINEERED WOOD - I ,TRUSS @ 24" O.C. U.N.O. HURRICANE ANCHOR @ EACHTRUSS (SEE UPLIFT SCHED.) W/ ' <br />METAL PL. UNDER EA. TRUSS <br />�/7MOISTURE BARRIER TYPICAL INTERIOR BEARING <br />SHINGLE ROOF <br />7/16"` O.S.B. MIN. SEE ROOF WALL W/OUT UPLIFT GG <br />NAILING SCHEDULE ON SHT. SEE TYP. WALL SECTION <br />SCALE: 3/4"=1'-0" <br />SN1 ELEV. VARIES FOR ADDITIONAL SLAB S3 <br />- INFORMATION. <br />ALUMINUM DRIP <br />EDGE <br />ALUMINUM FASCIA <br />2x SUB FASCIA <br />1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING - <br />NAILED W/ 8d COMMON NAILS @ 4" O/C <br />N.O. 2x S.P.F. STUDS @ 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. <br />EE SOFFIT v SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. <br />SHEET LOAD BEARING OR 2x STUD <br />(1) ROW 2x BLOCKING @ MID HGT. <br />FOR WALL HGT. < V-6". (2) <br />ROWS 2x BLOCKING @ 3rd PTS <br />FOR WALL HGT. > 8%6". <br />1/2" GYP. WB (MIN.) @ GARAGE <br />SIDE IF APPLICABLE. <br />5/8"- EXPANSION BOLT @24 " O.C. <br />W/ 7" EMBEDMENT (MIN. SHEAR <br />3500#, MIN. TENSION 2600#) c <br />E <br />6x6W1.4xW1.4 <br />WWF OR FIBERMESH <br />° _ 9W' T <br />lYAP .T. BASE NAILER D D ° 1 I=11= I=1 I = I I=1 I E ? o I #5 LAP SPLICE (2) #5 CONT. <br />4"x4" INSPECTION I—III—III=1 I I—III=1 I—� • i <br />NOTE: g D D III—III=1 i i=1 I=1 I=I 1- N <br />31/4" BASEBOARD PORT AT EACH *FOR BEARING WALL -i r COMP. SOIL. (COMPACTED TO <br />I-1 I I-1 I I=1 I I-1 I I=1 I I_ <br />FILLED CELL TYPICAL _ _ _ _ - __ =1 95% MODIFIED PROCTOR ASTM- <br />MIN. 2500 PSI CONC. SLAB W/ UPLIFT ONLY _ <br />c� AT GARAGE CONTRACTOR III= 1=III-III=III=III=1 =III=11=III=III=III=III=III=1 I= D1557) rrrirrr I l i - <br />MIN PSI MAY VARY PER �' TO CUT BLOCK OR POUR =III=1 I-III-III-III=III=III-III=III=III-III=III=1 i I=III- 4" 1' 4° <br />MUNICIPALITY. CURB DUE TO SLOPE <br />CONCRETE SLAB W/6X6 a NOTE:EXTEND FRAME WALL TO C.M.U. WALL CONNECTION D TYPICAL EXTERIOR FRAME WALL FOOTING <br />W1.4XW1.4 WWF OR DECO FINISH 4" to 6" <br />"FIBERMESH" SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=1'-0" SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" <br />c BELOW GRADE SLAB INFORMATION. S3 SLAB INFORMATION. <br />.� r <br />CV � � P •► � c Z_ <br />[ °O 6x6W1.4xW1.4 <br />`' ► eQ 31/2" WWF OR FIBERMESH <br />6 MIL VAPOR • z min. 4" <br />BARRIER >' �r 1 ° A 4 GRADE <br />D • a • <br />COMP. SOIL. • <br />(COMPACTED TO 95% <br />MODIFIED PROCTOR <br />ASTM D1557) <br />3" MIN. CLR. <br />(2) #5 REBAR CONT. <br />ON 3" CHAIRS TYP. 4" 1 STD. 90 HOOK (SEE <br />U.N.O. DETAIL) <br />TYPICAL WALL SECTION rA <br />SCALE: 3/4" =1'-0" S3 <br />OPT: DEPRESS SLAB 5Y" DEEP <br />AND 6" BEYOND DOOR TO IlIiI <br />RECEIVE PAVERS / DRIVEWAY BLOCK WALL BEYOND <br />CONCRETE SLAB <br />PAVERS- \ 14 7 `O.H.D. RECESS z <br />SEE A1S3 OR J/S6 _' 1 <br />FOR REINF. INFO. T,X' MIN. CLEARANCE <br />1'4" (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1' " (2 STORY) <br />GARAGE DOOR SLAB RECESS J.1 <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />'It`=li�il�ll�ll�li�ll'_ 11_ • . <br />MIN. <br />TYPICAL THICKENED SLAB EDGE L <br />SCALE:3/4"=1'-0" S3 <br />BLOCK WALL BEYOND <br />EXPANSION JOINT <br />13 O.H.D. RECESS <br />N <br />T <br />_ Cl) <br />cn <br />�C71 <br />a, <br />r - <br />+' °9 <br />4' <br />•, . <br />SEE A/S3 OR J/S6 <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 STC RY) <br />V-8" (2 ST RY) <br />GARAGE DOOR SLAB RECESS J <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />P.T. 2x 1/2" GYP. BD. <br />„ HOLD GYP. BD. <br />ol 1/2" FROM SLAB <br />CONT. BEAD SEALANT <br />a INTERIOR 2X STUDS @ 24" O.C. U.N,O. <br />-31/2° <br />GARAGE <br />CONCRETE NAILS W 1 1/2 GYPSUM WALLBOARD U.N.O. <br />EMBEDMENT @ 12" O.C. W/ DRYWALL SCREWS @ 8"O.C. <br />STAGGERED, FROM BOTTOM INSULATION PER CHART <br />PLATE TO CONCRETE ON FLOOR PLAN <br />(MIN. SHEAR 180# MIN. CONT. BEAD SEALANT <br />TENSION 120#) CONCRETE SLAB E <br />° 6x6W1.4xW1.4c`.i <br />c WWF OR FIBERMESH M <br />__—__= — rl I=1 ° <br />° ° <br />M 6 MIL VAPOR =-= i'rl 1=1 (_) 1= i,-1-9 1 1 <br />BARRIER <br />11=111 III =1 I I- <br />1I I III I I I, „III �' <br />4" 4" <br />INTERIOR WALL SLAB STEP NON-BRG. K <br />SCALE:3/4"=V-0" S3 <br />ON 3" CHAIRS <br />36" MIN. LAP [36"MIN. LAP] <br />10" <br />(TYP.)8" 1'-4" 8° <br />#6 REINFORCING BAR #5 STD. 90 HOOK <br />#6 LAP SPLICE <br />TYPICAL INTERIOR BEARING <br />REBAR DETAILS rF <br />WALL W/ UPLIFT G <br />SCALE: N.T.S. S3 <br />SCALE: 3/4"=1'-0" 13 <br />VARI <br />SEE PLAN <br />1 1/2" RECESS FOR 6 x 6 W1.4 x W1.4 . <br />FRAME -DOWN FALSE BEAM w/ (3) <br />SEE ROOF PLAN <br />S.G.D. (U.N.O.) WWF OR FIBERMESH E. <br />T <br />10d NAILS TO TRUSS TOP CHORD <br />FOR TRUSS <br />AT 24" O.C. MAX. <br />CONNECTION INFO <br />SEE PLAN FOR <br />& LAYOUT DESIGN <br />. . <br />TOP OF BEAM <br />SEE ROOF PLAN <br />oo <: ° ° < • ° ' <br />FOR STRUCTURAL <br />:= - <br />4' <br />BEAM SIZE & <br />N G <br />' <br />2x4 P.T. <br />CONNECTION INFO <br />_ • <br />PLATE <br />.•a.. <br />7/16" <br />O.S.B. <br />l <br />I 2x4 #2 SYP P.T. FRAMING w/ <br />' <br />MIN 7/16" O.S.B. SHEATHING <br />SEE A/S3/J/S6 8" <br />COLUMN LOCATION <br />z ATTACHED PER NAILING <br />FOR REINF. INFO. <br />OPTION #1 <br />W <br />° SCHEDULE <br />Q <br />j <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />> <br />SLAB INFORMATION. <br />w <br />Uj <br />SLAB STEP & RECESS S.G.D. rM <br />SCALE: 3/4"=1'-0" S3 <br />SEE FLOOR PLAN FOR <br />STRUCTURAL COLUMN SIZE <br />& BASE CONNECTION INFO. <br />SECURE 2x4 P.T. BTM. PLATE <br />MASONRY WALL AND <br />w/ 1/4"x3" TAPCONS AT 8" <br />PAD FOOTING <br />O.C. <br />8" MASONRY WALL <br />EXTEND FILL CELLS <br />TRIM PER PLAN <br />TO FOUNDATION PAD = <br />CONT. FOOTING STEEL <br />MAT REINFORCING. <br />SQUARE CMU BLOCK BASE, <br />. <br />M <br />= ° <br />C'RAPE <br />SIZE VARIES PER PLAN <br />°O <br />w/ MIN. (2) #5 VERTICALS <br />W III=III ° <br />z? °• <br />FILLED SOLID <br />W o I -I <br />ILL! Z <br />BRICK PAVERS or SLAB PER <br />O W COI=1 <br />00 -1 I I=1 ! • ° a -_ -_ _ z < <br />0'-0" FIN. FLR. <br />COMMUNITY SPECS <br />° <br />N - Q <br />=1 om I I=1 I I=1=1 I 11=III=1 I I-= W <br />=1 III=III=III=11 I-i I ill�1 1=1 1= FOOTING <br />ll l ll l l� l i l I -III -III-' BEYOND <br />,, ,., .• . <br />ll i ll ,I <br />PAD REINFORCEMENT II- <br />3" MIN. CLEARANCE <br />y.•y a :� SEE FOUNDATION <br />(SEE SCHEDULE) FOOTING WIDTH <br />.� .. ,�. CONC. PAD INFO. <br />SEE SCHEDULE <br />TAPERED <br />COLUMN FRAMING CD12 <br />PATIO COLUMN FTG. DETAIL N <br />SCALE: &4"= V-0' <br />SCALE: N.T.S. S3 <br />V Ul) <br />Z O <br />— O <br />Z N <br />Z QQQ <br />Q <br />i_ <br />t) (D <br />W cn <br />(DU <br />.}.J w <br />0 <br />— <br />C <br />O w <br />E <br />2 C, <br />U <br />W <br />F— E <br />— 8 <br />� In M <br />C of M <br />m .M <br />O O <br />= <br />U� <br />t LL2 CO <br />co <br />ma <br />Q CM <br />vr- <br />Ln O <br />0 <br />A' <br />MD. <br />N C.B•D C <br />i 0 <br />°ram/i <br />5 ,. • <br />..... <br />aj gyp• d S E <br />z <br />ii" <br />A 0� <br />°r ,C <br />tL <br />d� LL <br />- 4 <br />LL <br />Ul N <br />� <br />LL ;; F L.0' <br />W�,_ <br />2 <br />ov <br />a <br />E.,SI• <br />CJ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z N <br />00-4 �1� <br />05 M �O <br />M <br />-v t11 <br />6-cn•�d" <br />z <br />ql:r (n 0 <br />HN � <br />(R <br />oc v a <br />000 <br />Q E <br />(o <br />Z <br />J <br />W <br />Z.. <br />U) <br />8 <br />\� <br />1— <br />W ZZ <br />U OQQ' <br />W <br />W <br />0In <br />8 <br />Z8 <br />zItY <br />CI)Q <br />� <br />06 <br />3 <br />,--I <br />0 <br />o <br />=uj <br />C) <br />J <br />xO U <br />al <br />.. <br />0 <br />g <br />LL <br />^ <br />$g <br />Z <br />J <br />T <br />W$� <br />1Z8 <br />W <br />Z�$ <br />a <br />M <br />Z <br />W <br />IcaZ <br />o <br />gLU <br />g <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION No' 10 <br />SHEET NO. <br />S3 <br />(MONO) <br />