Laserfiche WebLink
- 4" THICK <br />1" <br />6" <br />NOTE: <br />• FIN. TO HAVE TRADITIONAL <br />LOOK & SMOOTH FINISH <br />• FOAM / EPS MATERIAL IS <br />ACCEPTED <br />� BRACKET DETAI L <br />• • _I�_i►3�. _ _ - — — — - — _ Via, — — — — — w • <br />TEXTURED BAND <br />ICI I_I1_I 00■ 0�0000 <br />111��11�=� _ �00�0000 <br />1 II 00■ 0000�0 _ �� <br />I_I l_I <br />17MIiMiIICIICII'Millm <br />4'-0" RIDGE VENT <br />T.O.P. — <br />16-0" RIDGE VENT <br />12 <br />;�1_5 <br />--- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />-------------------------------------------------------------- <br />TEXTURED 2,_011 <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />25 SH 25 SH <br />FRONT ELEVATION - Al <br />SCALE: 1/4"=1'-0" <br />RIGHT ELEVATION - Al <br />: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />0 PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />Is At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA I UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SQ. IN. OF NET FREE AREA/ FT. <br />" (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 72 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. <br />"Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 9 = linear Ft. of Deck -Air Needed) <br />• O'HAGIN ale Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />—Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 8e.25 = Amount of O'Hagin Vents Needed <br />�LOU <br />Z c <br />— o <br />Z (o <br />Z <br />Q <br />o-. <br />Z <br />cn <br />4--+ W <br />� p <br />U — <br />Ow <br />~ <br />= <br />o <br />o <br />Vi <br />� c) <br />0 <br />mr <br />M <br />W E <br />— 8 <br />of W cf M <br />V `r' <br />9 <br />�-• l`- 00 <br />000 <br />0 a r; <br />� <br />Qrn <br />Lo 0q V <br />1Qo <br />A ' <br />N C B D C <br />���>>�111111i1t11/ ` <br />\��• <br />N <br />PC'M� <br />N <br />•- <br />o1�1b• <br />o4 <br />24:� <br />Z. <br />N <br />lid Y <br />_ �4� <br />Q� <br />�`% �• 0 <br />• <br />E o Q` <br />v <br />$' Qt. � ��•� <br />.. <br />o`er <br />S S <br />,di <br />1O <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />0 <br />Z t'V <br />0 <br />CD <br />> <br />OD <br />M <br />Q 'gyp Ln <br />z <br />i2 tn•�� <br />0 <br />< C LL <br />Q `� <br />a3-f°a00 <br />z <br />a E� <br />z <br />z <br />WJ C:) <br />d. <br />z <br />w� <br />za <br />z <br />8L) <br />_O <br />w Z Z <br />�0 <br />LL7 <br />LU <br />N <br />� <br />J <br />LU <br />z <br />V <br />1 ` <br />c <br />LU <br />V <br />= <br />D <br />N <br />Zoo` <br />Q <br />LU CC <br />��XQ <br />z <br />W <br />In <br />LJJ <br />'19 6 <br />a <br />gr <br />z u <br />J <br />ri <br />zu <br />$ <br />Ln <br />M <br />Q <br />Z <br />Z <br />~ <br />co <br />_ <br />Z <br />9 � <br />rn O <br />,1 <br />a <br />cn <br />E <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />3.1 <br />