My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3168 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3168 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:46:07 AM
Creation date
2/27/2025 1:07:42 PM
Metadata
Fields
Template:
Building Plans
Street #
3168
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19112
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />NEMA 1 200 AMP #12 copper to 20 amp clns <br />#10.2 copper to WH <br />#10-3 copperto Dryer <br />METER II <br />MAIN -V <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 08, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />I ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />Qt <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />E <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />D9 <br />ELECTRIC METER <br />S <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />EEJPAD <br />DISC. <br />WP <br />GFI <br />1� <br />PATIO <br />W.I.C. ):�, <br />I <br />I ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />1 <br />OWNIER' <br />SUITE <br />I <br />k � <br />VERIFY METER LOCATION <br />WITH BUILDER <br />JOR <br />EDROOM 2L BED�OOM <br />ROUGH -IN FOR ROUGH -IN FOR <br />I ( OPT. CLG. FAN/ / OPT. CLG. FAN/ <br />II I LIGHT PRE-WIR� ,2\ LIGHT PRE -WIRE <br />OUGH-INFOR� <br />ell ' / <br />LIGHT PRE-WIR I !^ I �tDf*�M 4 <br />I <br />\ N11 S.D S.D <br />m m O O <br />O I[DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE C.M <br />HOOD PER SPECS-- -- <br />i <br />_ � i 1 • �1I V 1 <br />I� • a <br />Ul`H' I ' L l - — <br />1 L1 <br />I / / <br />/ ROUGH -IN F�R <br />/ OPT. CLG. F N/ LIGHT / 7-0" <br />PRE -WIRE I / <br />------------ <br />/ PENDANT AS <br />PER SPECS <br />FAMILY ROOM <br />CAFE <br />/ <br />/ <br />/ <br />/ <br />/ <br />Ak Ak <br />2.3 <br />VP <br />111 <br />k II II <br />OW <br />Qa <br />I <br />I <br />U <br />I <br />V <br />I <br />LL W <br />I <br />I <br />WW <br />w <br />I <br />' W 2-CAR <br />GARAGE <br />I @ 44 „ <br />A.F.F. <br />GARAGE 1 <br />I <br />/ <br />LIGHT AS <br />IGARAGE <br />/ <br />PER SPECS <br />DOOR <br />GFI <br />I <br />I <br />r <br />I 11 I <br />I ! 1 I <br />I <br />I I <br />II <br />I / IIJI <br />I <br />I <br />L------------ <br />GFI @ 44" A.F.F. <br />A IRRIGATION <br />,WP <br />GFI I <br />ENTRY <br />I <br />I <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />Z M <br />— o <br />Z CO <br />Z <br />Q <br />J <br />d <br />U, Z <br />V) <br />n ' <br />n <br />Q) N <br />w <br />I) <br />LLJ O � <br />O <br />TS ~ <br />,V U <br />O <br />m ~ <br />tll <br />I--- <br />— 8 <br />a�M <br />C l6 M <br />c`6 ;O cM <br />060 <br />= <br />yU_Go <br />.1C <br />Co* a o <br />Ln O : <br />Qrn <br />rnQ6 <br />A , <br />B Ds <br />N C B D C <br />� <br />� � N <br />N � <br />C � <br />tun oogrn <br />o olio <br />m M W C di <br />5aa <br />J Z <br />U_ J <br />LL <br />1� <br />MEE a) <br />W LL <br />a w <br />Ncm'ru < <br />Z� <br />t1 <br />0 <br />y=.W� <br />LL �E�� <br />W <br />0 mmo^ <br />d� <br />as <br />tV <br />J o <br />0 <br />O U <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z No <br />0 � I� <br />�°o <br />M <br />QU-)'(0pLn <br />Q �J U_ Lfl <br />ZC' M <br />Q E06 <br />Z <br />W CD <br />J � <br />d' <br />W - <br />za <br />�a <br />o: <br />gWWOt <br />Uo�z <br />J <br />a f <br />U <br />�oL© <br />Z p <br />W <br />Z <br />N <br />w <br />V <br />= <br />0W <br />O <br />o� <br />ZOQ <br />Z <br />W <br />O p U U0� <br />Q <br />oo <br />ZLu <br />LuQ <br />Z <br />2 <br />o�Z <br />W <br />LJ J <br />Q <br />� o <br />Ln <br />M <br />Q <br />Z <br />uj <br />Z <br />Z <br />Uj <br />M <br />^ <br />g <br />o <br />� <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.