My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3217 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3217 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 2:52:49 PM
Creation date
2/27/2025 1:08:35 PM
Metadata
Fields
Template:
Building Plans
Street #
3217
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
20166
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br />rn <br />rY <br />N <br />cV <br />CD <br />Z. <br />rn <br />N <br />4 <br />00 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A <br />INDOOR PANEL <br />CENTER <br />III #14 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />111, #12 copper to 20 amp ckts <br />01 #10-2 copper to WH <br />01 #10-3 copper to Dryer <br />METER <br />MAIN <br />O <br />2/0 or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED---. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />----------------------------------------------- <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />� < <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />E <br />SD <br />SMOKE DETECTOR <br />o <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />i <br />TELEPHONE (OPTIONAL) <br />L` <br />TELEVISION (OPTIONAL) <br />E2 <br />o <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />0,I <br />O <br />THERMOSTAT <br />.o <br />ELECTRIC METER <br />i <br />a <br />ELECTRIC PANEL <br />a <br />_ML-A <br />DISCONNECT SWITCH <br />t" <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />6� <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER LOCATION <br />WITH BUILDER <br />MAIN ELECTRICAL PLAN <br />SCALE: %4°=1t-0" <br />U <br />Z ch <br />— O <br />z� <br />a <br />i� <br />W <br />4— <br />w <br />�_ Q <br />Z — <br />O"' <br />c <br />E <br />0 <br />~ <br />U <br />m r` <br />M <br />w <br />rat ~ <br />c M <br />ro Cl) <br />O o N <br />C) <br />a�0 <br />U_co <br />Cc <br />�Y� <br />11 o72 <br />¢ rn <br />a < CS <br />B D. <br />N�� <br />=J1 <br />�7�Z y Za' � <br />zLJL Z <br />_ .iMOc <br />LL, <br />p <br />W mLL <br />W <br />W O <br />Z25- <br />Z <br />Z N! oo <br />m m <br />LLW W ¢ <br />N—N is <br />M <br />0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z cV <br />O a� <br />14+-Jo <br />> (n M O <br />4.1 <br />Q U) <br />lP, <br />Z <br />Q ll <br />M <br />�U n00 <br />Z § E <br />Z <br />WJ <br />� <br />d' <br />J <br />oZ <br />W� <br />Za <br />f <br />w ¢ it a <br />U Z 8 O <br />ZdLZUQ <br />j ZZ Z <br />0Oa,!� W <br />Z <br />ILWoU) <br />t <br />Scio <br />Q <br />oZ <br />zZ <br />Q_ <br />aU <br />> <br />V <br />o <br />T� <br />O <br />V <br />w <br />U <br />= <br />W <br />L J <br />uj <br />o'er <br />o <br />0 N <br />J T'I <br />xOU <br />� <br />¢ <br />z <br />c <br />G <br />�aa3 <br />< <br />o 2: <br />Z <br />Lr) <br />a�o� <br />J <br />rl <br />LU <br />Q <br />W <br />Z <br />�Wo <br />Zu <br />z <br />� <br />N <br />Z <br />? <br />m <br />` <br />Ouj <br />00 <br />2 <br />Z <br />,--i <br />a <br />to <br />g <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAMES <br />VERSION NO. 4nO <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.