Laserfiche WebLink
3z�F�f V�rlNb,eal�[�_ <br />3 <br />-v <br />c <br />v <br />r` <br />0 <br />0 <br />CV <br />r-- <br />s <br />o <br />� El FF-7-1 ElEl� FF-11 ILI <br />EIFE] EIE]EI <br />EEJ❑ El E71❑ � 7EA <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAILS <br />4 <br />ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />ROOF FRAMING PLAN <br />8 <br />LINTEL DETAILS <br />SIN <br />STRUCTURAL NOTES <br />ABBREVIATIONS <br />SN1 <br />DETAILS <br />AB or A.B. Anchor Bolt <br />ABV or Abv. Above <br />AC or A/C Air -Conditioner <br />ADJ orADJ. Adjustable <br />AFF or A.F.F. Above Finished Floor <br />AHU or A.H.U. Air Handler Unit <br />ALTorALT. Alternate <br />BC Base Cabinet <br />BF Bifold Door <br />BK SH or Bk Sh BookShelf <br />BLK or BLK. Block <br />BLW or BLW. Below <br />BM or Bm. Beam <br />BOT or Bot. Bottom <br />BP or B.P. Bypass (door) <br />BRG or BRG. Bearing <br />C Carpet <br />CAB Cabinet <br />CIR or Cir. Circle <br />CJ or C/J Control Joint <br />CLG or Clg. Ceiling <br />CMU Concrete Masonry Unit <br />COFF or Coff. Coffered or Tray Ceiling <br />COL or Col. Column <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />Cor CONN. Connection <br />CTT or or C.T. Ceramic Tile <br />D or D. Dryer <br />DB Door Bell <br />DBL or Dbl. Double <br />DCF Decorative Cementitious Finish <br />DEC or Dec. Decorative <br />DED or Ded. Dedicated (outlet) <br />DIA or Dia. Diameter <br />DISP or Disp. Disposal <br />DIST or Dist. Distance <br />DMF Decorative Masonry Finish <br />DS or D.S. Drawer Stack <br />DTL Detail <br />DV or D.V. Dryer Vent <br />DVP or D.V.P. Diverter Valve (plumbing) <br />DW or D.W. Dishwasher <br />EA or Ea. Each <br />EW or E.W. Each Way <br />ELEC or Elec. Electrical <br />ELEV or Elev. Elevation <br />EQ Equal <br />EXT or Ext. Exterior <br />EXP or Exp. Expansion <br />FBC Florida Building Code <br />FDN or Fdn. Foundation <br />FXD GL Fixed Glass <br />FG Fiberglass (Shower Pan) <br />FIN Finished <br />FIN FLR or FF or Fin. Flr. Finished Floor <br />FIX or FXD Fixed <br />FLR or Flr. Floor <br />FLR SYS or Flr Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />FP or F.P. Fireplace <br />FR DR French Door <br />FRT Front <br />FT or Ft. Foot/ Feet <br />FTG or Ftg. Footing <br />GALV or Galy. Galvanized <br />GC or G.C. General Contractor <br />GFI or G.F.I. Ground Fault Interrupter <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />HB Hose Bibb <br />HDR or Hdr. Header <br />HGT or Hgt. Height <br />HH or H.H. Hand Held (plumbing faucet) <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />ILO In Lieu Of <br />INSUL or Insul. Insulation <br />INT or Intnt . Interior <br />KIWALL or KIWall Kneewall <br />KS or K.S. Knee Space <br />LAUN or Laun. Laundry <br />LAV or L L.F.Lavatory <br />LF or . Linear Ft. <br />LL Lintel Length <br />LT Laundry Tub <br />MGT Management (room) <br />MAS or Mal Masonry <br />MAX or Max Maximum <br />MC Medicine Cabinet <br />MFR or Mfr. Manufacturer <br />MW or MICRO or Micro. Microwave <br />MIN or Min Minimum <br />MIR or Mir. Mirror <br />ML or M.L. Microlam <br />MONO or Mono Monolithic <br />NTS or N.T.S. Not to Scale <br />OE or O.E. Owner's Entry <br />OPNG or Opn'g. Opening <br />OPT or Opt. Optional <br />PC Pull Chain <br />PED or Ped. Pedestal <br />PH Phone <br />PKT or Pkt. Pocket (Door) <br />PL or P.L. Parallam <br />PLF Pounds per linear foot <br />PLT HT or Plt. Ht. Plate Height <br />PLNT SHLF or Plt. Sh. Plant Shelf <br />PSF Pounds per square foot <br />PT or P.T. Pressure Treated <br />PW or P.W. Pre -wire <br />PWDR or Pwd. Powder Room <br />RA or R/A or R.A. Return Air <br />RAG or Rag. Return Air Grill <br />RAD or Rad. Radius <br />REC or Rec. Recessed <br />RECEPT Receptacle <br />REF or Ref. Refrigerator <br />REINF Reinforcing <br />REQD or Req'd. Required <br />RM or Rm. Room <br />RND or Rnd. Round <br />RO or R.O. Rough Opening <br />RS or R/S or R&S Rod and Shelf <br />SD or SO. Smoke Detector <br />SQ FT or SF or S.F. Square Foot (feet) <br />SGD Sliding Glass Door <br />SH or Sh. Shelves <br />SHWR or Shwr. Shower <br />SHT Sheet <br />SL or S.L. Side Lights <br />SPF or S.P.F. Spruce Pine Fir <br />SPECS or SPECS. Specifications <br />SQ or Sq. Square <br />STO Storage <br />SW or S.W. Shear Wall <br />SYP or S.Y.P. Southern Yellow Pine <br />TB Towel Bar <br />TEMP or Temp. Tempered <br />THIKN or Thik'n. Thicken <br />TOB or T.O. B. Top of Block <br />TOM or T.O.M. Top of Masonry <br />TOP or T.O.P. Top of Plate <br />TP Toilet Paper Holder <br />TR Towel Ring <br />TRANS WDW or Trans. Transom Window <br />TYP or Typ. Typical <br />UC or u.c. Under Counter <br />UCL Under Cabinet Lighting <br />UNO or U.N.O. Unless Noted Otherwise <br />V or v. Valve (shower or tub/shower) <br />VB Vanity Base <br />VERT or Vert. Vertical <br />VL or V.L. Versalam <br />VTR Vent through Roof <br />W or w Washer <br />W/ or w/ With <br />WC or W/C or W.C. Water Closet (toilet) <br />WA or W.A. Wedge Anchor <br />WD or Wd Wood <br />WDW HDR or WDW. HDR. Window Header <br />WH or W.H. Water Heater <br />WIC or W.I.C. Walk-in Closet <br />WM or W.M. Wall Mounted (plumbing fixture) <br />WP Water Proofing) <br />WS Water Softener <br />WWF Welded Wire Fabric (Mesh) <br />S3S <br />STEM DETAILS <br />S4 <br />DETAILS <br />S5 <br />DETAILS <br />SS <br />RETROFIT DETAILS <br />D1 <br />SECTIONS & DETAILS <br />WP <br />WATERPROOFING DETAILS <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />PA1.3 <br />PRODUCT APPROVAL NUMBERS <br />REVISIONS <br />08-20-15 1.0 NEW BASE PLAN <br />12-8-15 2.0 FRAME -WALK REVISIONS <br />12-28-17 3.0 2017 FBC UPDATES <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. <br />PREVAILI <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />G 7E5 DL <br />ORpIt�r�A „ <br />.,, DN <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. SEE <br />FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />1791 <br />U <br />zo <br />z�z <br />Q <br />U, zClLl <br />W � <br />a-1 ry <br />�V <br />Ow <br />.� <br />C6 U <br />Co°� <br />LU <br />IDM <br />C f0 M <br />U <br />c CV <br />o ro 00 <br />� o <br />Q & <br />0 Ma <br />ci <br />A 1 <br />B D. <br />N y` <br />� <br />N N <br />N Z fi Z <br />LU — � CL a <br />W VZ <br />��Z`` 0 t.MIA, a <br />o , <br />;1,Lk� <br />W.£D ENG. <br />U� <br />0 F- <br />l� <br />•rltit.. `4 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential eth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />5 <br />°C <br />o <br />za <br />�z00 <br />U <br />S=ZZ <br />VOW <br />a Co <br />Co <br />��O <br />1 <br />U w w <br />OLU <br />LU <br />Z O <br />Zz <br />Q <br />O <br />Q <br />O <br />�Crao <br />0-1 <br />T <br />V ■ <br />� <br />w06 <br />1__1 <br />Z� <br />UM': <br />Q� <br />�. <br />i o <br />�o�2 <br />Z <br />Z <br />*—� <br />8 �j <br />J <br />Ll <br />UJ <br />E <br />LL <br />g <br />Q <br />aZU <br />f—`U <br />$wg <br />M <br />ko <br />Z <br />L <br />a Z <br />m <br />O <br />00 <br />Z <br />g <br />= <br />rn <br />,-1 <br />a <br />(n <br />o <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAM ES <br />VERSION NO. 4nO <br />SHEET NO. <br />C S <br />