My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3244 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3244 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:53:04 PM
Creation date
2/27/2025 1:08:46 PM
Metadata
Fields
Template:
Building Plans
Street #
3244
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
20168
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEE STRUCTURAL NOTES AND BACKNAIL W/ (2)16d NAILS BACKNAIL w! (2)16d NAILS SIMPSON H1OA w/ (18) SIMPSON SP4 w/ 6 10d x <br />TOENAIL W! (2) 16d NAILS SIMPSON H10A w! (18) ( ) <br />NAILING SCHEDULE FOR 2"x4" 1Od x 1 12" AT EA. 1 12" AT EA STUD USE BACKNAIL w/ 2 16d NAILS SIMPSON H10A w/ 18 <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. SEE STRUCTURAL NOTES ( () ( ) <br />SHEATHING DETAIL OUTLOOKER OUTLOOKER SP6 FOR 2 6 WALL USE 1 1 12" AT EA <br />@ 24" O.C. <br />NAILING SCHEDULE FOR <br />OUTLOOKER <br />AND NAILING SCHEDULE <br />TOP CHORD <br />SHEATHING DETAIL <br />@ 24" O.C. FOR SHEATHING <br />DETAIL <br />BLOCKING FOR <br />•'' <br />FIRST FOUR <br />ROWS OF <br />45° f 24" MAX. <br />TOP CORD BLOCKING <br />45'± <br />2X4 CONT"L" BRACE <br />TOP CORD BLOCKING <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)1Od 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" 0/C. CMID HEIGHT <br />OF TRUSSES EDGES <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />G <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. 2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />EXTEND AT LEAST 90% OF <br />48" O.C. EACH JOINT W/ (3) 10d <br />MAX. & (2)1 Od TOE NAILS @ <br />AT LEAST 90% OF WEB <br />@ 8'-0" 0/C. <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />' <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />i <br />J <br />SIMPSON HGAM11 <br />W/ <br />(4) 1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (� <br />1 /4"x2 3/4" <br />TITEN TO CMU <br />2x6 P.T. GABLE TRUSS <br />RIDGE FASTENED AT <br />H2.5A w/ (10) 8d <br />SILL 1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROMLSIMPSON <br />FROM LEDGER TO <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ <br />BLOCKING <br />ATTACHED W/ 1 Od <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1 OdX3" @ 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />7 <br />1!2"CDX PLYWOOD OR 7/16" <br />SHEATHING ATTACHED <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />1 6" O.C. <br />10d NAILS <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ <br />w/ @ <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4 "T" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />- NOTCH "L"BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ (2 <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)10dx1 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />10dx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1 Od NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4) 1/4"x21/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION <br />O.C. MAX) w/ MIN. 4" <br />1 EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />Srj <br />TITEN ON OUTSIDE <br />SIMPSON H10A w/ (18) <br />BACKNAIL W/ 2 16d NAILS <br />L <br />x <br />SEE STRUCTURAL <br />NOTES Od x <br />SP8 FOR 2x8 WALL) <br />AND NAILING SCHEDULE <br />FOR SHEATHIN <br />OUTLOOKER <br />DETAIL <br />2x4 OUTLOOKER <br />F@ 24" 0/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />O.C. (OPTIONAL - SEE <br />4" MAX. <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4" CROSS BRACE <br />24" MAX. EDGES OF <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />EACH JOINT W/ (2)1Od & (2)10d <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE &SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2)16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />NAILS <br />ATTACHED w/ 10d NAILS <br />W/ 1 Od NAILS @ 6" O.C. EDGES <br />AND 12" O.C. FIELD <br />TRUSSES FROM EA. <br />END TYP. TOP & <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />(2)16d NAILS <br />BOTTOM ATTACHED <br />48" <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M <br />2x4 "T" ON TOP OF PANEL <br />SIMPSON <br />1 Odx3" @ 4" O/C <br />HGAIOKT w/ (4)1/4"xl 1/2" <br />BLOCKING, FASTEN WITH <br />SDS SCREWS <br />TO TRUSS & (4) 1/4"x3" <br />10dx3" @ 4" 0/C <br />SDS SCREWS <br />TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12)10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT DBL. TOP PLATE <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. SCJ <br />() 1 Od x 1 12" AT EA. <br />2x4 OUTLOOKER <br />REFER TO DETAIL J <br />iv <br />N <br />SEE STRUCTURAL <br />OUTLOOKER <br />@ 24" O/C <br />ON SHEET S5 FOR <br />r <br />NOTES AND NAILING <br />TOP CORD <br />X-BRACING, AND TOP <br />N <br />N <br />SCHEDULE FOR <br />BLOCKING FOR <br />CHORD BLOCKING <br />`° <br />� <br />°° <br />SHEATHING DETAIL <br />FIRST FOUR ROWS <br />INFORMATION <br />OF TRUSSES @ <br />1 <br />1 <br />1/ " <br />2"x4" CROSS BRACE <br />24" MAX. <br />EDGES OF <br />• WOOD TRUSSES <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />-2X4 RAT RUN BRACING <br />. <br />EACH JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />AT 24" O.C. ON TOP OF <br />10d & (2) 10d TOE <br />LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 <br />NAILS @ EA. END <br />GABLE TRUSS <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />/� <br />(jUl� <br />2x4 PANEL BLOCKING <br />1/2"CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT <br />�� <br />@ 48" O/C FOR THE <br />(2)16d NAILS <br />OSB SHEATHING ATTACHED <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2 x 6 LAMINATIONS W/ (2) ROWS OF <br />FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />E <br />ES AND 12" O.C. FIELD <br />2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />JACK TRUSS <br />O/C w/ (2)16d <br />TOENAILS @ EA. END <br />NOTES: <br />BOTTOM ATTACHED <br />SEE PLAN FOR <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />w/ (2)16d TOENAILS <br />CONNECTION <br />MASONRY WALL <br />OF THE COLUMN <br />(SPACE AS SHOWN FOR 3-PLY) <br />r, <br />-ARCHITECTURAL FINISH <br />2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE <br />THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL <br />2x4 "T" ON TOP OF PANEL <br />OF THE LAST LAMINATION <br />(SPACE AS SHOWN FOR 3-PLY) <br />BLOCKING, FASTEN WITH <br />2x4 BLOCKING WV, , <br />1 Odx3" @ 4" O/C <br />(2)12d TOENAILS <br />EXT. WALL CONN. @ 3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION <br />NON - LOAD BEARING LOCATION COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />D B.U.C., SAME NUMBER OF ROWS, SAME SPACING) <br />SEE TYP. WALL SECTION FOR SCALE: =1'-a' TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS $ SECTION g` <br />S S5 i' <br />= ADDITIONAL INFORMATION. <br />co <br />9 <br />CV <br />MINIMUM 2x <br />CROSS BRACING <br />m <br />(SEE PLAN FOR <br />LOCATIONS) <br />Ir <br />(2)16d PER <br />JOINT <br />f— CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />N <br />CROSS BRACING DETAIL ri <br />SCALE: N.T.S. <br />2"x4" OUTLOOKER @ 24" O.C. W/ (2)10d PER JOINT <br />10dx3" O/C @-� 2"x4� <br />TOENAIL 6" O/C RUNN <br />W/ (2)16d TYPICAL <br />NAILS _.... <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />o � <br />v "L" BRACE W/ 10d @ 4" O.C. <br />� <br />12 (SEE SCHEDULE FOR SIZE <br />o AND LOCATION) <br />6.9 MAX. <br />"— 5 <br />E <br />0 <br />S5 <br />x <br />L <br />c <br />J <br />O <br />O <br />6 <br />S5 <br />0 <br />i <br />U <br />N <br />CONT. BEARING <br />GABLE END BRACING DETAIL <br />LU MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SCALE: N.T.S. <br />SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />SCALE: N.T.S. SrJ <br />-MINIMUM (2)16d PER JOINT MINIMUM 2X4 TRUSS BRACING <br />/ 1 1r.1. A r•. .1rT A .. M <br />SCALE: N.T.S. Srj <br />6" OVERLAP <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)1 Od <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />w <br />BRACING w/ (3)10d x 3" AT <br />EACH CONN. @ 24" O/C <br />SIMPSON HGAMIOKTA w/ (4) MOISTURE BARRIER <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4) 1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />ut--- <br />2x4 BLOCKING 2x4 7' BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />1Od NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL/'_6 <br />SCALE: N.T.S. , <br />DIAPHRAGM <br />BLOCKING @ <br />48" 0!C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE J <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE 7 <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 CONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />�I <br />I■III <br />INS <br />INS <br />hqh, <br />116,111111phi., <br />� <br />__ <br />I�It� <br />- <br />ICI <br />� <br />I■III <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. NON - LOAD <br />BEARING LOCATION(UNEVEN CLG.) E <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. SrJ <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" - T-O" <br />3'-0" - 6'-0" <br />6-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 1063" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"xl 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4"x3" SDS SCREWS <br />TO PLATES (TYP.) <br />/—GABLE TRUSS <br />�-CONT. BEARING <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />HIP FRAMING REFERENCE PLAN <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) 7' BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />a <br />/TOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />z M <br />o <br />z�z <br />a <br />U) z <br />(n CD <br />CU C„ <br />+-J LU <br />� o <br />•p <br />w <br />N 0'_ <br />E <br />o0 <br />Co <br />W <br />1 6r., <br />N C' <br />t0 M <br />,8 N <br />O <br />gi <br />o <br />o <br />¢� <br />N no <br />�S72� <br />rn Q o <br />B DW <br />` <br />. <br />N N <br />Z W ���z G' z <br />H NLLo S <br />a " V <br />LUw <br />� Uj <br />Z 0 <br />O C' <br />°m <br />�' <br />. B <br />WLZ <br />44 ¢"�-; �2 °o <br />LUN <br />e <br />t���41aitftifll'ia� " F- <br />rr ❑� <br />s <br />;�` ` .. <br />-- `` • <br />����) <br />_J <br />//rr+rlfi, \0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />Z <br />H <br />Z< <br />0. <br />i~ZO° <br />zW <br />�z <br />0. J <br />O��o <br />L <br />z u <br />N <br />y O <br />fZ <br />0Y <br />�\ <br />z <br />�C <br />a <br />w <br />0 <br />-0 <br />C)Q <br />O <br />`J <br />Z <br />qj <br />US <br />Opz <br />0 <br />o 00cY� <br />J C) <br />s <br />v 0 <br />ro- <br />N <br />Ir <br />w'< <br />a¢�oe <br />z <br />Z <br />Lu <br />J�--� <br />LJJ <br />Q ! J <br />z <br />2: <br />Q <br />ZI',S <br />$a� <br />F- H <br />M <br />ko <br />Z <br />co <br />_! <br />W <br />:5= <br />LU <br />LU <br />Z <br />1z <br />0 <br />a <br />cn <br />o <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: MJAMES <br />VERSION N0. 480 <br />SHEET NO. <br />S5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.