My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3246 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3246 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:01:40 PM
Creation date
2/27/2025 1:08:57 PM
Metadata
Fields
Template:
Building Plans
Street #
3246
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
19517
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ + <br />+ . + + + + + + + <br />+ + + + + + + + + + + + i + <br />+ <br />+ <br />+ + + + + + + + 4 <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + r <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ <br />+ + <br />6'-0" <br />6'-0" <br />^++ <br />+++++ <br />++ <br />+++ <br />+ <br />+ + + + + + <br />+ <br />+ + + + + + + + + + + <br />+ + <br />+ + <br />+ + + ++ c <br />Z++ <br />+ + <br />+ + + r + + + + + + <br />+ <br />+ <br />+ + + + + + io <br />+ <br />++ + + + + .r + + + + <br />+ + <br />++ <br />+ <br />++++++++ <br />+ <br />cr' <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />`—RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />r E a <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />,Hood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />FILL CELL <br />w <br />> STD. 90° <br />CONT. #5 <br />BAR I HOOK <br />STD. 900 HOOK BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />USP <br />MUGT15 TYP. <br />GIRDER TRUSS <br />- CONT. #5 <br />BAR <br />2X TOP PLATE <br />5/81 <br />#5 CONT. <br />THRU <br />FROM <br />BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D :!-' <br />�` PLYWOOD FLOOR <br />! <br />COLUMN AND = SHEATHING PER PLAN <br />CONNECTION <br />/Y TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />Ktr <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all from # OF 2nd FLOOR <br />p ° STUDS <br />above to bearing below. <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />+ <br />i 1/8" min. Small a 2" min. <br />+ / 2" max.) gap 4" max. Web Stiffener Fastener Schedule <br />/ <br />+ Joist Bearing Location <br />Series Depth End I Intermediate <br />9-1/2" 2-8d 2-8d <br />— - BCI 5000s® 11-7/8" 2-8d 3-8d <br />14„ -- 2-8a -�=$d <br />Clinch nails 9-1/2" 2-8d 2-8d <br />7 <br />when BCI 6000s® 11-7/8" 2-8d 3-8d <br />possible I BC16500s® 14" 2-8d 5-8d <br />_._y __ 16" 2-8d 6- <br />8d <br />1) Support back of web during nailing to prevent damage to - 11-7/8" 2-8d 3-8d <br />web -flange connection. - BCI60s® !-, _.,_-2-8d 5-8d <br />2) Block solid between joists for full length of span, Tight fit = " - 16" 2-8d 6-8d <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 11-7/8" 3-16d 3-16d <br />2x4/Plywood/OSB web stiffener 2" min. BCI 90s® __ 14"_ 5-16d 5-16d <br />�, 4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x-: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite required when indicated or 4 max. 16" 6-16d 6-16d <br />- Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Ye" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />over squash=20 blocks and <br />Non -stacking walls <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or-20 sinker <br />lateral load. nail each side <br />10'-0" <br />7 at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" <br />STUB -OUT FOR <br />GAS METER - <br />O Q o in <br />� � <br />v O_ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR 3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR 4 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />1514" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />I Isr+ v" f 1 n& nails at All n r, <br />T Provide adequate bearing <br />for each lapped joist. <br />odnails SECTION `) INT. BRIG. WALL <br />N.T.S. <br />KNOCKOUTS) ALLOWED MINIMUM SPACING = 2x GREATEST <br />IN BEARING ZONES D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.- <br />6�� A 1 2' ROUND HOLE MAY 6�� 6�� DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %22" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALL SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Joist hanger <br />I.0 <br />US <br />ML <br />TYPICAL USP MUGT15 TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) �IrT <br />f f JNail with 10-10d nails.m-- — <br />nstall tight to top flange.•SLEEVRU STEM <br />SEE PLAN FOR---'4. <br />°. • . • <br />FOUNDATION INFO ' <br />4. <br />STEM FOUNDATION <br />Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />Top Mount "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required rf hanger <br />flange is laterally supported by joist hanger, doesn't meet <br />height <br />`l requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />rvt, %,nmoc,+ rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF NOTE: <br />SUPLIFT VALUE <br />SECOND RT16 <br />IS BASED ON <br />S.P.F. <br />= USP RT16 USING <br />16-8d x1 1/2" NAILS <br />' UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />a <br />4 4: e <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE/F I <br />PENETRATION PLUMBING LINE <br />q 4 4 <br />a 4 / <br />v'4 4+ <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 a 4 <br />4°' <br />A 4 4a G <br />•a <br />a <br />a 4 < IR� <br />SEE FND. PLN. <br />01 SIZE & REINF. <br />Z g <br />Z <br />Z <br />J <br />fl- <br />L/)'' (D <br />cn <br />4--J w <br />0 <br />U — <br />0LLJ <br />L° <br />= <br />o <br />00 <br />�M '— <br />C) <br />°D r, <br />a� M <br />w E <br />+— <br />— $ <br />OE <br />TV In <br />0.20 <br />0 <br />_M <br />M1�10 <br />� LL 00 <br />a <br />Qrn/ <br /><6 <br />A 1 <br />8 Do <br />N <br />IN <br />tr' •..1�N <br />`J � <br />i <br />��j <br />$_h C, �� <br />N <br />J�i <br />Oti co <br />J•iO1JA <br />...1W <br />!1�.M <br />. tll to 1w0 ,• , <br />UQ'ii g <br />�^, <br />to � <br />fw l Yj 1 <br />�Ca <br />LU <br />Ca <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />CD <br />Z N <br />0 <br />to M CO <br />M <br />QU-)(0Ln <br />z <br />V) <br />clY V o. <br />z <br />Q 00 <br />z E <br />its <br />Z <br />WJ C:) <br />d- <br />�a <br />Li o80 <br />VU <br />S u� z <br />8�a <br />0 ® <br />/ <br />LL <br />O <br />R U <br />?` <br />Ce <br />Ti <br />z <br />a <br />O <br />� <br />= <br />F-- <br />. <br />io-v <br />buds <br /><o <br />c <br />Z <br />d. <br />Fizw3 <br />J <br />In <br />UJ <br />!2 a <br />Zi-g <br />l0 <br />Z <br />Z <br />LU <br />m <br />� <br />_ <br />,--t <br />a <br />cn <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />SN 1 <br />